Osaki EI-8502A Massage Chair Instruction Manual

June 5, 2024
Osaki

Osaki-EI-8502A-Massage-Chair-LOGO

Osaki EI-8502A Massage Chair

Thank you for purchasing this Massage Chair. Before using your massage chair, please read the contents of this instruction manual and refer to it when needed.

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using (this appliance).

DANGER

To reduce the risk of electric shock:

  • Always unplug this appliance from the electrical outlet immediately after using and before cleaning.

WARNING To reduce the risks of burns, fire, electric shock, or injury to persons:

  • An appliance should never be left unattended when plugged in. Unplug from outlet when not in use, and before putting on or taking off parts.
  • Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled persons.
  • Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
  • Never operate this appliance if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged, or dropped into water. Return the appliance to a service center for examination and repair.
  • Do not carry this appliance by supply cord or use the cord as a handle.
  • Keep the cord away from heated surfaces.
  • Never operate the appliance with the air openings blocked. Keep the air openings free of lint, hair, and the like.
  • Never drop or insert any object into any opening.
  • Do not use outdoors.
  • Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
  • To disconnect, turn all controls to the off position, then remove the plug from the outlet.
  • Keep children away from extended foot support.
  • Connect this appliance to a properly grounded outlet only. See Grounding Instructions.
  • Use heated surfaces carefully. May cause serious burns. Do not use over insensitive skin areas or in the presence of poor circulation. The unattended use of heat by children or incapacitated persons may be dangerous.
  • Do not operate under a blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons.
  • Never use pins or other metallic fasteners with this appliance.
  • Carefully examine the covering before each use. Discard the appliance if the covering shows any sign of deterioration, such as checking, blistering, or cracking.

Safety Precautions

When using the massage chair, basic precautions should always be followed to reduce the risk of electric shock, burns, fire, or injury to persons. Please read the following precautions before using the massage chair.

  • Make sure the power plug is securely inserted into a proper electrical outlet to reduce the risk of short-circuiting and fire.
  • It is highly recommended that a surge protector is used to prevent damage.
  • DO NOT use the massage chair in areas where the humidity is high such as sauna steam rooms, pools, bathrooms, AC or heating vents, etc.
  • DO NOT use the massage chair outdoors and avoid areas with direct sunlight.
  • If the chair is not being used, turn the power switch to the OFF position and unplug the massage chair from the electrical outlet to prevent any damage to the chair when there are power outages/surges that may cause serious damage.
  • Never plug/unplug the power cord plug socket with wet hands.
  • Close and continuous supervision is necessary when the massage chair is used by, on, or near children or disabled persons.
  • No more than one person should use the massage chair at the same time.
  • The massage chair is intended for use as described in the Instruction Manual. Dot does not use any attachments other than those recommended by the manufacturer.
  • DO NOT attempt to stand or sit on the backrest, armrest, or footrest in order to prevent an accident, injury, or damage to the chair.
  • Avoid falling asleep while using the massage chair.
  • Always keep the massage chair clean, and never insert any objects into or around the gaps of the massage chair.
  • DO NOT move the massage chair by pulling on the power supply cord.
  • Make sure there are no children, pets, or other obstacles behind or underneath the massage chair.
  • If you find any rips or tears in the fabric of the massage chair, contact the service department and stop using the chair immediately.
  • This massage chair is designed for household use and should not be used in non-residential settings.
  • Please consult your doctor if you are in doubt as to whether or not you should use this massage chair.
  • Please consult a doctor before using the massage chair if you are pregnant, undergoing any medical treatment, using a medical electronic device such as a pacemaker, or are experiencing any of the following: malignant tumor, heart disease, back pain, abnormal or Curved backbone, osteoporosis, or acute illness.
  • If you experience pain while using the massage chair, stop using the chair immediately and consult your doctor.
  • Never use a massage function on swollen or inflamed parts of the body.
  • DO NOT use the massage chair for more than 30 minutes at a time.
  • DO NOT use the massage chair where aerosol(spray) products are being used or where oxygen is being administered.
  • This massage chair is a non-professional product designed to provide a comfortable massage and should not be substituted for appropriate medical treatment.
  • Never operate the appliance with the air hoses that inflate while they are blocked. Keep the air openings free of lint, hair, and any other obstructions.
  • Check the skin which is in contact with the heated area of the appliance frequently to reduce the risk of injury. If the heating pad malfunctions and extreme heat is produced it may cause serious burns.
  • Burns may result from improper use. If this is the case immediately shut off the chair and unplug from the outlet.
  • Remove all sharp objects from the body and pockets Such as keys and pens.
  • Keep children away from extended foot support (or other similar parts)
  • DO NOT WET-DO NOT USE PINS.
  • NEVER REMOVE THE COVER.

caution
no user’s weight is usually limited to 220 bs. For those who are weighing 220 Ibs or more, the product operations may make more noise and the fabric cover may wear out faster.

FCC Radiation Exposure Statement

FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation.
FCC STATEMENT

  1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
  2. This device may not cause harmful interference, and
  3. This device must accept any interference received, including interference that may cause undesired operation.
  4. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.

Industry Canada Notice

Industry Canada Notice
This device complies with Industry Canada licence-exempt RSS standard(s).

  1. Operation is subject to the following two conditions:
  2. this device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device.
  3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Chair Components

Osaki-EI-8502A-Massage-Chair-
FIG-1

  1. Shoulder side massage section
  2. pillow Pad
  3. Backrest Pad
  4. Hand and am massage section
  5. Seat Cushion
  6. Legrest

Bluetooth Speaker

NOTE: The Bluetooth speaker can only connect with one Bluetooth device at a time. Please turn off your Bluetooth device after using it so that other users can enjoy it as well

Air Massage AreaOsaki-EI-8502A-Massage-Chair-FIG-3

Chair Installation

  1. Take out the main unit and accessories from two boxes.Osaki-EI-8502A-Massage-Chair-FIG-4
  2. Connect the wires and air pipes from the footrest and seat part respectively.Osaki-EI-8502A-Massage-Chair-FIG-5

Setting up the massage chai

Installation Position.

  • Ensure there is adequate space to recline.Osaki-EI-8502A-Massage-Chair-FIG-6
  • Do not expose the massage lounger to direct sunlight or high temperatures, such as in front of heating sources, because this can cause discoloration or hardening of the synthetic leathe.
  • Place the unit on a mat to prevent floor damage.
  • When placing a mat under the unit, the size of the mat should be sufficient to cover the areas where the unit touches and where the legrest could touch the floor, as shown in the diagram on the above
  • Install the unit near a power outlet.

Preparation before Use

  1. Check the space around the product.
    Make sure there is no person, pet, or other object close to the product.

  2. Make sure there is no foreign matter in the seams of the product.

  • Before sitting on the product, make sure there is no foreign matter between any two parts of it.
  • Do not put hands, arms ,or head between the backrest and the back cover.
  • Do not put pets on the product (such as its back cover, backrest ,and armrests).

Preparation before Use

Power on the product

  1. push the power connector into the appliance inlet till the end.
  2. Insert the power plug into the power outlet till the end.
  3. Turn the switch to “T positionOsaki-EI-8502A-Massage-Chair-FIG-9
  4. Make sure the massage rollers are retracted.

If they are not, press the ON button to return them to the retracting position.

HOW TO USE

ControllerOsaki-EI-8502A-Massage-Chair-FIG-11

Product Operation Guide
Connect to the power supply, then turn the switch to’l”position, thus the chair will be in idle mode,and the backrest angle will reach the highest position as well as the footrest angle will reach the lowest position.During its idle mode, there are only five functions:ON/OFF, Incline, Recline, Incline Leg, Recline Leg that can be operated. Control Buttons for the Massage Chair

  1. ON/OFF
    The Start/Stop Control Button Press this button to light up the LCD screen. Press any massage function button to start the massage. This will initiate the timer function. Press this button again to stop all massage functions, the massage chair will return to its original position.

  2. TIMER
    Time interval Control Button When a massage function is activated, the timer is reset at 15 minutes. Every a single press on this button will change the timer interval in the sequence of 20> 25 30> 5> 10 15 > 20 minutes.

  3. PAUSE
    Press this button once to halt the current massage function and countdown timer. During pause mode, the pause button will be blinking. Press this button again to cease the Pause function and resume the previous massage function as well as the countdown timer.

  4. Zero Gravity
    Press this button to activate the Zero Gravity function. press again to return to idle position.
    Note: Zero Gravity button is NOT controllable during auto programs of Thai.

  5. LEGREST RECLINE AND RESTORE
    Angle Adjustment Button for Leg rest. Keep pressing either button until the leg rest reaches your desired position.

  6. CHAIR RECLINE AND RESTORE
    **** Keep pressing position. to comfortably lay flat or to restore the chair to its original

Full body Auto massage program

  1. GENTLE

  2. RELAX

  3. THERAPY

  4. VIGOROUS

  5. DEMO

  6. SWEDISH

  7. THAI

  8. CHINESE

  9. EGREST LENGTH ADJUSTMENT BUTTON
    These two control buttons can adjust the length of cthe hair legrest.P ress or once to lengthen or shorten the chair legrest.
    Notes :
    Please press the button gently to avoid sticking the button. When ZGR is activated before any program ,the chair will scan and adjust the length of lthe eg rest automatically.

  10. WIDTH
    The Width Adjustment Button for Rolling Function. When Rthe olling function is engaged, every single press on this button will change the massage width interval in the sequence of Narrow>Wide in cthe ycle.

  11. Spot
    The Spot Back massage This button allows the user to select spot massage for any part on the back. Press this button ato ctivatespot massage at the required location.
    Press this again to switch to partial function.

  12. Partial
    The Partial Back massage. Press this button to switch to partial function.

  13. Roller up/ Roller down
    The massage position adjustment button for spot and partial massage. When the manual or automatic shoulder scanning can’t meet individual, requirements, you manual fine tune the shoulder height location by pressing uthe p/ down button within sound 8 seconds. Once aan ppropriate location fis ound rto elease the key, the final position will be lock.
    Note: In the spot or partial massage,y ou can also use these two buttons to adiust the massage position. Manual Massage Program

  14. KNEADING
    Kneading function Start Stop Control Button -5 levels of strength to be adjusted Press this button to activate rhythmic mode 1 Kneading function for a full back massage at medium strength. Press the button again to activate mthe ode 2 Kneading function. Press the button for the third time to stop Kthe neading function and switch to mode 1 Swedish function.

  15. SWEDISH
    Swedish function Start/Stop Control Button -5 levels of speed to be adjusted.
    When mode 2 Kneading function is engaged, press this button to activate rthe hythmic mode 1 Swedish function for a full back massage at medium speed. Press this button again to activate mode 2 Swedish function. Press once more to stop the Swedish function. To activate Swedish function directly, press this button 3 times during idle mode.

  16. TAPPING
    Tapping function Start/Stop Control , 5 levels of speed to be adjusted. Press this button to activate rhythmic mode 1 Tapping function for a full back massage at medium speed. Press the button again to activate mode 2 Tapping function. Press the button for the third time to stop Tapping function and switch to mode 1 Shiatsu function.

  17. SHIATSU
    Shiatsu function Start/Stop Control , 5 levels of speed to be adjusted. When mode 2 Tapping function is engaged, press this button to activate rhythmic mode 1 Shiatsu function for a full back massage at medium speed. Press this button again to activate mode 2 Shiatsu function. Press once more to stop the Shiatsu function. To activate Shiatsu function directly, press this button 3 times during idle mode.

  18. CLAPPING
    Clapping function Start/Stop Control ,5 levels of speed to be adjusted. Press this button to activate rhythmic mode 1 Clapping function for a full back massage at medium speed. Press the button again to activate mode 2 Clapping function.P ress the button for the third time to stop Clapping function and switch to Rolling function.

  19. ROLLING
    Rolling function Start/Stop Control Button -2 levels of width to be adjusted. When mode 2 Clapping function is engaged, press this button to activate Rolling function for a full back massage.P ress this button again to stop the Rolling function. To activate Rolling directly, press this button 3 times during idle mode.
    Note: This function cannot perform “the Spot” massage function.

  20. Foot Roller
    Foot roll function Start/Stop Control Button. Press once to activate the roller on foot, pand ress again to stop the foot roll function.

  21. LED LIGHTING
    LED Lighting Function Start/Stop Control Button. Press this button to activate Lthe ED lighting function. Press again to stop the LED Lighting function.

  22. HEAT
    Lumbar Heat function Start/Stop Control Button. Press this button to activate lthe umbar heat function, press this button again to stop the Heat function.
    Note: During Auto Program mode, pressing this button can also disable/enable the Heat function.

  23. Intensity
    The Intensity Adjustment Button for Air-pressure-5 levels of intensity to be adjusted. After activating the air-pressure function(Auto and Manual), press this button to adjust the intensity in the cycle.

  24. SPEED
    The Speed Adjustment Button for Tapping, Clapping, Rolling, and Shiatsu function. When the Tapping, Clapping, Rolling or Shiatsu function is engaged, every single press on this button will change the massage speed interval in the sequence of ” Lv1 > LV2

  25. STRENGTH
    The Strength Adjustment Button for kneading function.
    When the Kneading function is engaged, every single press on this button will change
    the massage speed-strength interval in the sequence of ” Lv1 > Lv2 > Lv3 > Lv4

    Lv5 ” in the cycle.
    Setting Air Squeeze

  26. SHOULDER
    Shoulder Air Squeeze Massage Control Button -5 levels of intensity to be adjusted. Press this button once to activate rhythmic air massage at the shoulder Press this button again to stop the function.

  27. BACK & SEAT
    Back and Seat Air Squeeze Massage Control Button 5 levels of intensity to be adjusted. Press this button once to activate rhythmic air massage at the back and seat. Press this button again to stop the function.

  28. HAND
    Hand Air Squeeze Massage Control Button – 5 levels of intensity to be adjusted. Press this button once to activate rhythmic air pressure massage at Hand Rest. Press this button again to stop the function.

  29. FOOT
    Footrest Air Squeeze Massage Control Button -5 levels of intensity to be adjusted. Press this button once to activate rhythmic air pressure massage at Footrest. Press this button again to stop the function.

  30. Full Body Air Pressure Massage

Full Body Air Pressure massage. Press once to activate the air-pressure massage at full-body Press again to stop the function.
Finish Operating
Please press the ” ON / OFF ” button after use. Massage Rollers will restore to its original position: then switch the power supply button under the chair to ” o ” and unplug the machine from the wire socket.

Cleaning and maintenance

Cleaning of the synthetic leather
Wipe the synthetic leather with a soft dry cloth. Do not clean the product with chemicals Such as thinners, gasoline, and alcohol. When using a leather maintenance product cleaning cloth) sold on the market, follow directions for use.* If the synthetic leather is very dirty, wipe it with the method below.

  1. Put a piece of soft doth into water or 3% to 5% neutral detergent container nor water and wing
  2. Wipe the surface of the synthetic leather with a soft cloth.
  3. Wipe the detergent with a piece of cloth once soaked in ocean water and wrung out.
  4. Wipe with a piece of a wrung soft cloth.
  5. Have synthetic leather take natural air drying.
  • If it is difficult to remove the stains on the synthetic leather, oak a piece of melamine foam bought from the market into a neutral detergent and use it to wipe the product
  • Do not dry the surface with a hair drier.
  • The surface of the synthetic leather may be dyed with fabric denim or colored cloth png ne product with
  • Synthetic the leather used should be covered by a towel. ea vol discolor, so the position in contact

Cleaning of the plastic parts

  1. Put a piece of soft cloth into water or neutral detergent containing hot water, wring it out, and wipe the plastic parts. Do not clean the product with chemicals such as thinners, gasoline, and alcohol.

  2. Wipe with a piece of cloth once soaked
    in clean water, and wrung out. Wring the doth out before using it to wipe the remote controller,

  3. Have the plastic parts take natural air trying.

Troubleshooting

This page summarizes the most common problems you could encounter with the product. If you are unable to solve the problem with the information below, contact the service center immediately. If the problem encountered is not listed, please try the following suggestions:

  1. Turn off the product and unplug it.
  2. Wait for 60 minutes.
  3. Plug the product back into the recommended outlet and restart.
  4. If the problem persists, contact the authorized service center.
Problem Possible Cause Suggestion

The product does not work

|

The product is not plugged in properly.

| Ensure the voltage on the product corresponds to the local mains voltage and then plug in again. Make sure the outlet is properly working.
The product stopped working| The product has just finished its auto-timer session and has automatically switched to standby mode.| If you want another session, press the Power button again.
The product stopped working| You may have used the product continuously for 45 minutes where the overheat protection has been activated.|

Unplug the product and let it cool down for 60 minutes before you use it again.

The product does not work| An excessive load has been applied to the product.| Reduce the excessive load and start again.
The product is abnormally warm|

The product is likely to be overused.

| Unplug the product and let it cool down before using it again.

Noise can be heard from the product

|

Noise is made by the mechanical parts of the product.

| This is normal and does not mean that the product is faulty.

Grounding Instructions

This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for the electric current to reduce the risk of electric shock. This product is equipped with a cord with an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Danger-Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if the product will not fit the outlet, and have a proper outlet installed by a qualified electrician. This product is for use on a nominal 120V circuit and has a grounding plug that looks like that plug illustrated below. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product.Osaki-EI-8502A-Massage-Chair-
FIG-14

Chair Specifications

Osaki-EI-8502A-Massage-Chair-
FIG-15

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Osaki User Manuals

Related Manuals