Osaki LK-219 Spa Capsule Installation Guide
- June 8, 2024
- Osaki
Table of Contents
Osaki LK-219 Spa Capsule
Please read the SAFETY INSTRUCTIONS carefully before using this device.
SAFETY INFORMATION
When using the spa capsule basic precautions should always be followed to reduce the risk of electric shock, burns, fire, or injury. Please read the following precautions before using the spa capsule.
- Make sure the power cord is plugged into the proper outlet to reduce the risk of short-circuit and electrical fire.
- We highly recommend using a surge protector to avoid damage.
- Do not use the capsule on a slanted surface where the risk of rolling is high.
- Do not use outside or in areas of heavy direct sunlight.
- When not in use, unplug the capsule to avoid possible damages from power outages/surges that may cause serious damage or harm.
- Never plug or unplug the capsule’s power cord with wet hands or a wet cable.
- There should never be more than one person in the capsule at a time.
- Do not use the capsule if your head does not comfortably and fully extend outside of the hole.
- Close supervision is imperative when children or disabled persons are on or near the capsule.
- Children, pregnant women, disabled individuals, patients with high blood pressure, and people with heart disease should not use this device.
- Burns may result from improper use.
- This spa capsule is intended for use as described in this instruction manual. Do not use attachments or modifications other than those suggested by the manufacturer.
- Do not stand on the seat and do not sit or stand on the armrest, backrest, or lid to avoid serious injury or damage to the capsule.
- Avoid falling asleep during use.
- Ensure the capsule is clean and operational before use.
- Do not move the capsule by pulling on cords or hoses.
- Make sure there are no children or animals underneath or behind the capsule before use.
- If you find any cracks or defects in the capsule you should contact the service center immediately.
- Please consult your doctor if you have concerns before using the capsule.
- If you experience pain or lightheadedness while using the capsule cease use and consult your doctor immediately.
- Do not use the capsule for more than 45 minutes at a time.
- Keep hands and appendages away from the lid while closing.
- This is a recreational item and should not be used as a substitute for appropriate medical treatment.
- Do not repair circuits or wiring by yourself, please call the distributor or send an email to a service specialist.
PREPARATION & SETUP
Set-Up:
-
Positioning:
Position your capsule on a flat surface with easy access to both a 120V outlet and a waterline, making sure to leave enough room behind the capsule for the water reservoir. -
Connections:
Begin by connecting the main power supply to a nearby surge protector or wall outlet. If you’d like to utilize the showerhead, please connect a waterline to the rear at this time (A). Place a water reservoir underneath the drainage pipe behind the spa capsule (B). -
Steam Generator:
Ensure the exterior steam generator is plugged in and the white steam hose is connected to the lid (C). Flip the power switch to the on position before using (D).
Set-Up
This diagram should assist you in finding the connections and placements of your secondary items
HOW TO USE
Preparation
- Begin by filling the steam generator with water. If you’d like to add essential oils, do so before turning the device on, as to avoid potential harm.
- Press the power button on the control panel and activate the desired mode(s). (i.e. steam, ozone, chromotherapy)
Control Panel
Operation Instructions
- Power Switch: Press once to power the Spa Capsule on, and again to power it off.
- Light Control: Press once to turn on chromotherapy, and a second time to turn it off.
- Steam Control: Press to begin the steam exfoliation.
- Temperature/Timer Increase: Increases temperature or timer depending on selection.
- Temperature/Timer Decrease: Decreases temperature or timer depending on selection.
- Timer Adjustment: Select to start or adjust the timer. The suggested time is 20-30 minutes.
- Temperature Adjustment: Select to set the preferred temperature. The suggested degree is between 107ºF & 113ºF.
- Volume Increase/ Next Song: Press to increase the volume of the current song or switch to the next song.
- Volume Decrease/ Last Song: Press to decrease the volume of the current song or replay the last song.
- Switch Between Volume/Song Control: Press to toggle between song control or volume control.
- Toggle MP3 Power: Toggle the power of MP3 on or off.
- Shower Head Control: Turn on the showerhead for easy cleaning of the capsule’s interior.
- Ozone Control: Turn on for an increase of oxygen in the system. The suggested use is for 10 minutes.
Functions
-
Steam Sauna:
By simply filling the water reservoir with water you can experience a conditioning and relaxing steam massage. This will hydrate your skin and open your pores. -
Fragrance Therapy:
You have the option to add essential oils, herbs, milk, or honey to the water reservoir in order to experience a calming fragrance in addition to your steaming refresh. Different essential oils provide a variety of benefits for you to choose from. -
Auditory Relaxation:
Listen to your favorite music or calming sounds by plugging in an external device via USB to compound the relaxing effects of your spa capsule. -
Ozone Rejuvenation:
By activating the Ozone system, you can clear out your pores of toxic metals. This is achieved through ‘ozone sterilization’, a process unique to your spa capsule. -
Chromotherapy:
Activate the chromotherapy function on your spa capsule to begin a calming series of fading lights. This rhythmic set of lights can relax your body, soothe the mind, and improve metabolism.
CLEANING & MAINTENANCE
Cleaning
-
Interior:
Cleaning the interior of the Spa Capsule is designed to be as easy as possible. When connected to a water line, the shower head can be used to rinse the interior of the pod with clean water. -
Water Caches:
There are two caches where loose water will begin to pool. One underneath the floorboard, and one behind the capsule. These two reservoirs should be routinely drained and emptied. -
Exterior:
You may use any everyday cleaning solution to disinfect and clean the exterior of the pod. Never use any liquids on or near the electrical outlets, wires, or control panel.
Maintenance
- When not in use, the capsule should remain unplugged and powered off.
- Before use, the user should always check for cracks in the exterior or frayed wires.
- If any defect is present, please contact service@osakititan.com before using the capsule again.
TROUBLESHOOTING
This page summarizes the most common problems that you may encounter with your Spa Capsule. If you are unable to solve your specific problem with the solutions listed below, please contact the service center immediately.
Problem: | Potential Solution: |
---|
The Spa Capsule doesn’t
turn on:
| Ensure that the local voltage matches the required voltage; Try another
outlet; Unplug and plug it back in; Check the power switch or fuse.
The is no steam:| Check the water pipeline for kinks or blockage, make
sure your waterline is connected properly.
The display isn’t on:| Ensure the capsule is plugged in and turned on;
check the status of the fuse.
The lights aren’t functional:| Ensure the capsule is plugged in
and turned on; Check on the wiring; Turn on the switch.
No Ozone Operation:| Turn on the switch, and make sure the option is
selected.
The MP3 player doesn’t work:| Ensure the device is plugged into the USB
port, and the MP3 option is selected.
The speakers don’t work:| Troubleshoot the MP3 player first; check on
wiring; replace the speaker itself.
The Capsule is abnormally warm:| The capsule has been in use for too and
is overheating, turn it off and unplug it for at least 60 minutes and resume
use.
If the problem is not listed below, please try the following suggestions:
- Turn off the Spa Capsule and unplug it
- Wait for 60 minutes
- Plug the product back into a different outlet and restart it
- If the problem persists please contact our service center
SPECIFICATIONS
Brand | Osaki |
---|---|
Model | LK-219 Spa Capsule |
Input Voltage | 120V |
Frequency | 60Hz |
Open Dimensions | 67”(H) X 29”(W) X 59”(L) |
Closed Dimensions | 51”(H) X 29”(W) X 50”(L) |
Volume | 4L |