Osaki TheraMedic Massage Bed Instruction Manual

June 9, 2024
Osaki

Osaki TheraMedic Massage Bed Instruction Manual
Osaki TheraMedic Massage Bed

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using (ihis appliance).

DANGER-To reduce the risk of electric shock:

  • ‘Always unplug this appliance from the electrical outlet immediately after using and before cleaning
  • Never use pins or other metalic fasteners with this appliance.
  • Carefully examine the covering before each use. Discard the appliance ifthe covering shows any sign (f deterioration, such as checking, blistering, or cracking,
  • WARNING–To reduce the risks of bums, fire, electic shock or injury to persons:
  • An appliance should never be left unattended when plugged in. Unplug from outlet when notin use, ‘and before puiting on oF taking off pars,
  • Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled persons.
  • Use this appliance only for is intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
  • Never operate tis appliance if thas a damaged cord or pug, its not working property, if ithas been dropped or damaged, or dropped into water. Rum the appliance toa service center for ‘examination and repair
  • Do not carry this appliance by supply cord or use cord as a handle
  • Keep the cord away from heated surfaces.
  • Never operate the appliance with the air openings blocked. Keep the air openings free of lint, hai, ‘and the like
  • Never drop or insert any object into any opening
  • Do not use outdoors.
  • Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
  • To disconnect, tum all controls tothe off positon, then remove plug from outlet.
  • Keep children away fom extended foot suppor.
  • Connect this appliance to a propery grounded cult ony. See Grounding Instructions.
  • Use heated surfaces carefuly. May cause serious burns. Do not use over insensitive skin areas or in the presence of poor circulation. The unattended use of heat by children or incapacitated persons may be dangerous.
  • Do not operate under blanket or pilow. Excessive heating can occur and cause fre, electric shock, ‘or injury to persons.
    SAVE THESE INSTRUCTIONS

GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for the electric current to reduce the risk of electric shock.
This product is equipped with a cord withan equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Danger- Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Grounding Instruction

OPERATING SURROUNDINGS

  • OPERATING ENVROMENT

  • Do not use or store the massage chair under damp conditions:

  • i.e. bathroom, sauna, spa, to avoid any mold development, electric

  • shock, fire or mechanical failure.

  • Don’t use the massage chair outdoors

  • Don’t use the massage chair under dusty and temperature varying conditions.

  • Don’t place the massage chair near heater(s), stove or direct

  • sunlight to avoid inner components overheating which may lead

  • electrical fires and shock.

  • Make sure to place the massage chair on flat level ground surface

  • The chair should be placed on carpet, wood or hard surface flooring

  • Make sure the power plug is properly grounded to avoid shock and

  • injury.

  • Don’t use the machine while smoking

FOLLOWING CONDITIONS REQUIRING CONSULT FROM A MEDICAL DOCTORS BEFORE USE

  • Suffered from malignant tumor
  • Serious heart disease
  • Serious skin disease
  • Bone disease
  • While pregnant or menstruating
  • On rest by the doctor
  • Spinal condition including injuries associated to the back and spine
  • Hypertension and cramping
  • Arthritic bone disease
  • Any implanted medical device such as pacemaker
  • Suffering from internal conditions (i.e. gastritis, entritis, diarrhea,
  • Zepatitis)
  • Serious blood circulation trouble
  • Consciousness issues such as vertigo and other equalibrium matters

WARNING
Children under the age of 18 years old or with physical or mental condition are not permitted to use this product unattended by an able adult and with the permission of a medical doctor. These purcautions are taken to prevent injury and damage to the product
For safety reasons and in order to clearly indicate potential dangers should the product be used improperly, instructions have been marked in the following manners and should be strictly noted

CAUTIONS


Non-authorized technicians are not permitted to dismantle or repair this product to avoid fire, electrical shock or serious injury


Do not clean or wipe down this product with anything wet or moist when this symbol is shown.


When storing or during maintenance, be sure to disconnect the power plug from socket. Do not detach the plug with wet hands


Make sure to turn the power switch to the “off” position and detach
the power plug when cleaning or storing the product


During cleaning or when moving the chair, make sure to detach power
cord from the wall and chair to avoid fire or electrical shock
Do not place the machine on a unstable, uneven and unleveled surface to avoid sana, insulation failure or electrical shock


When storing the machine, make sure to disconnect power plug from the outlet and chair to avoid fire caused by electrical surges.


Clean power plug periodically to avoid buildup leading possible fire


Do not use it at any unsafe area or for any other purposes than personal use. Not for commercial use.


Do not store the chair in areas that are not climate controlled. Must be in room temperature with very low humidity.


Keep the power cord unobstructed at all time, i.e. not twisted, knotted, over bent or pulled and do not place anything heavy on it

CAUTIONS


Do not make any modifications or change components by an unauthorized person


Do not dismantle the machine by unauthorized person to avoid short-circuit or fire


Do not store it near a fire, heater or flammable substances It is one of the major
reasons of causing product damage.


Should any abnormality occur(i.e. burning smell), stop using immediately and detach power plug from outlet.


please contact your local seller or authorized service agent for maintenance to avoid electrical fire and injury.


Only proper rated voltage must be used . Stop using immediately if power cord,
‘or power plug is damaged or net tightly fitted into the outlet or the base of the chair


Be sure to keep children and pets away while operating to avoid any injury

Do not place the chair in direct sunlight a ll mes


If the supply cord is damaged, it must be replaced by the manufacturer or an authorized technician

NAME OF EACH PART

Name Of Each PartName Of Each
Part

Pressure attention

Force is strictly prohibited in the ABS shell of the foot of the machine. It is not allowed to carry, break, impact, impact, etc.

It is forbidden to sit around the neck pillow.

When working on this machine, it is strictly forbidden for objects, animals or people to sit close to or under the equipment.

It is strictly forbidden to disassemble the machine, especially the electronic control part.

For leather, cloth and ABS, use of hard objects is strictly prohibited.

PRODUCT INTRODUCTION

720′ Therapy conditioning (approximately 30 min)

Start running, a torneticaly start the five dements musk and far infrared heating can manually&Must the volume and turn off far infrared heating.
First step| Step 2| Step 3| Step 4| Step 5| Stop 6
Gradient
pressure( about 6 min)| Acoustic
vibration
(about 3 min)| Weight
traction
(about 5 min)| Acoustic
vibration
(about 3 min’| Hi-speed sieve (about a min)| Gradient
pressure
( about 9 Min)
360° Therapy conditioning (approx mately 20 m n)
Start fuming. autormaticaly Start five elements music and tar infrared heating. can manually adjust the volume and turn oil far infrared hea no.
First step| Step 2| Step 3| Step 4| Steps 5| Step 6
iracloot prawn {Approximately 5 min)| Acoustic
vibration (about
2 min)| weight traction
(Approximately
3 end)| Acoustic
vexation (about
2 min)| Hi-speed sieve
(About 2 min)| Sralant pressure
(approximat epy 5 inn)
Gradient pressure conditioning (approximately 25 min)
Start running, automaticaty start five elen,onts music and far infrared heating can namely adjust the volume and tum off far infrared heating.
From neck, spine, leg to toot circdaVon seouence of pneumatic physiotherapy. each POSION. Row times, ciectiatica total time of about 25 min; nth; Suggest far infrared can.
Acoustic vibration conditioning (about 10rnin)
Start fuming. autcmatICaly start five elements music and far infrared heating. can Manua”), adjust the volume and turn oil tar infrared heating.
Honzontal position, lateral vibration, engem:matey 10 min,
Gravity traction conditioning (about 10min)
Start running. automatically start five elements music and far infrared heating, can manually adAdt the volume and turn off fat infrared heating.
The whole back of the machine is inclined told’ (loot Mag, headrating). 5 air bags in the spine cbturation ri turn pneumatic physiotherapy. conditioning tame 10min. recommended to open far infrared nypertnermia
Hi-speed sieve conditioning (approximately 10 min)
Start runreng. automatically start five elements music and far airfare(‘ heating. can manually 6cguSt the volume and turn off far Offered heating.
Horacrital position. longitudinal vibration. About 10 min of conditioning,

INSTRUCTIONS ON CONTROL PANEL

Instruction On control Panel

OPERATION GUIDE

| On/Off button: press this button to start massage, press again to shut down.
---|---
| Stop button: press this button to stop massage.
| 720 ° Therapy conditioning button: press this button to enter 720 ° therapy conditioning mode. (For details of the model, please refer to P9. Instruction)
| 360° Therapy conditioning button: press this button to enter 360° therapy conditioning mode.(For details of the model refer to the P10. of this specification)
| Gradient Pressure conditioning button: press this button to enter Gradient pressure conditioning mode. (For details of the model, please refer to PI0. instruction)
| Acoustic vibration conditioning button: press this button to enter acoustic vibration conditioning mode. (For details of the model refer to the P10. of this specification)
| Weight traction conditioning button: press this button to enter self weight traction conditioning mode. (For details of the model refer to the p10. of this specification)
| Hi-speed sieve conditioning button: press this button to enter Hi-speed sieve conditioning mode. (for details of the model refer to the p10. of this specification)
| MENU button: press this button to return to the home page.
Up/down Button Icon| Direction button: press these two buttons to flip the m enu TAB .
| Settings: press the button to setting menu.
| Heating button: when machine starts, the heating automatically opens by default, press this button one time to turn off, and press again to turn on.
| Increase the volume button: press this button to increase the volume of music playing.
| Reduce volume button: press this button to reduce the volume of music playing.
| Mute button: press this button to mute.

TROUBLESHOOTING

Fault phenomenon Confirmation Processing methods
The machine doesn’t work when the power is on The power switch of this
machine is not turned on Turn on the switch
No native function selected Select native function
Poor contact with plug and socket Make the plug in good contact with the

socket
Power cord or plug damaged| Please entrust the manufacturer, designated repairman or qualified
Fuse damage| Replacement of fuses of the same maintenance personnel to check and replace specifications
Failure of internal control circuit| Entrusting the designated maintenance department to check and repair
This machine is working “dis da or the buzzing| Sound produced when air pumps, notors and mechanical components work| Normal phenomena without any treatment
The sound suddenly got bigger at work| Is it too long| Cut off the power and let the machine rest for more than half an hour before restarting it
The wear of mechanism caused by longtime use is a nrxmal phenomenon| Please entrust the designated maintenance department to check and repair
The machine suddenly stopped| Is there a sudden power outage| Re-energize power
May press the stop button| Re-select conditioning mode
Abnormal heating of power cord or plug| Possible overload| Cut off the power and let the machine rest for more than half an hour before restarting it
There may be other anomalies| Stop use immediately and entrust the designated maintenance department to inspect or repair

SPECIFICATIONS

Product name Massage bed
Product model TheraMedic
Rated voltage 12OV- 6OHz
Rated power 80VV
COIOF Pearl Grey & Brown
Safety design Category 1

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals