System Cabling
All system cabling (excluding mains 240vAC supply) has been tested with Cat5E
UTP PVC cable.
Part Number – A8NFORCE5EUTP
Find this product on line:
elandcables.com I Cables & Accessories I LAN Cable I Cat 5E UTP PVC Cable
System Components
Optional Accessories
Installation
Site the door station a recommended 1.5 meters from the ground, or to suit application.
The camera needs to point in the direction of where a visitor will stand during operation.
Avoid areas of high sunlight and noise levels.
Surface mount the sunshield of the door station and connect the system cabling. Mount the camera to the sunshield by fixing with the supplied hex screw.
System Connections Example 1
System Connections Example 2
The system power supply can support up to 5 devices
- Only one monitor is set as the MASTER:
- All other monitors set as SLAVE:
- Refer to instructions supplied when using different version of monitor for MASTER/ SLAVE configuration
Lock Connections Example 1
Lock Connections Example 2
-
The jumpers on the rear of the door station offer different types of release modes for alternative applications dependent on the jumper link settings. LOCK1 options;
-
Jumper 1 gives the option to set the release time;
-
The door station has a secondary switch. LOCK2 options;
-
Please refer to the operation guide for release instructions
User Guide
Installer’s Guide
Master / Slave Setting
When using multiple monitors on 1 system;
Only the 1 handset set as the MASTER will display an image when the door
station is activated.
All other monitors will ring, and will display the image once the ‘Talk’
button is pressed.
In the event of no video or audio signals coming from the monitor, or if the call button or audio cannot be activated on the door station, check the following;
A That the system is powered sufficiently.
B Each monitor needs to be set to a MASTER or SLAVE position
C All system cabling is secured and properly connected.
D All system cabling is clear of breaks or short circuits.
E Bench test the system if the issue cannot be found.
In the event of a lock release issue,check the following;
A The user instructions and operation of the monitor has been understood.
B That the lock is powered sufficiently.
C All system cabling is secured and properly connected.
D All system cabling is clear of breaks or short circuits.
E On the rear of the door station, ensure the lock output is switching when
activated by the monitor.