ESP MAGPRO9601 Addressable Fire Alarm Panel User Guide
- May 15, 2024
- ESP
Table of Contents
ESP MAGPRO9601 Addressable Fire Alarm Panel
Product Information
Specifications
- Product Name: MAGPRO9601 Addressable Fire Alarm Panel
- Model Number: MAGPRO9601
- Colour: Black
- Power Source: Electric
- Network Connectivity: Yes
Product Usage Instructions
FAULT Events Review in the System
When a FAULT event occurs in the system, follow these steps:
- Review the FAULT EVENT Indication.
- Check the FAULT Message for details.
- Identify the specific fault, such as Battery Loss or Periphery Device issues.
Turning off the Buzzer for FAULT Events
To silence the buzzer for FAULT events, perform the following:
- Select the specific fault, e.g., Loop Device Fault, Zone 1.
- Access the menu and choose to Silence the Alarm or Buzzer.
- If operating in a network, follow specific instructions to turn off the buzzer.
WARNING Events Review in the System
For WARNING events in the system, take the following actions:
- Review the WARNING EVENT Indication.
- Check the warning message for details.
- Note that WARNING messages may not be displayed automatically on the panel.
Turning off the Buzzer for WARNING Events
To silence the buzzer for WARNING events:
- Select the warning event, e.g., Clean me now, Zone 1.
- Access the menu and choose to Silence the Alarm or Buzzer.
- If operating in a network, select the panels where you want to turn off the buzzer.
FIRE ALARM Events
When a FIRE ALARM is triggered, follow these steps:
- Identify the zone where the fire alarm is activated.
- Evacuate as necessary based on the alarm location.
- Follow any specific instructions provided for FIRE ALARM events.
FAQ
- Q: How do I report a FAULT or WARNING event?
- A: Call the MAINTENANCE SERVICE and provide details of the event including type and location.
- Q: How do I know when to evacuate during a FIRE ALARM?
- A: When a FIRE ALARM is triggered, evacuate immediately based on the indicated zone and address information.
User Quick Guidelines for MAGPRO9601 Addressable Fire Alarm Panel
FAULT Events Review in the System
FAULT EVENT Turn off the buzzer
In case of Operation in Network, turn off the buzzer as chosen:
Check the type of FAULT!
WARNING Events Review in the System.
NOTE: The WARNING Messages for events are with lower priority and they are not displayed automatically from the panel!
WARNING EVENT Turn off the buzzer:
- In case of Operation in Network, choose the panels, where to perform Turn off Buzzer.
Check the type of WARNING!
Call the MAINTENANCE SERVICE and report the type of FAULT or WARNING event:
- Tel.:……………………………………………….
- Mobile:…………………………………………..
- Responsible person:………………………………………………………………………..
User Quick Guidelines for MAGPRO9601 Addressable Fire Alarm Panel
FIRE Event in the System
- FIRE ALARM EVENT, time delay set for Sounder, Fire and Fire Protection outputs Turn off the buzzer:
- In case of Operation in Network, turn off the buzzer as chosen:
- REAL FIRE ALARM, time delay set for Sounder, Fire and Fire Protection outputs Start Evacuation:
- In case of Operation in the Network, start Evacuation as chosen:
- Turn off sounders and Reset:
- In case of Operation in Network, choose the panels, where to perform Turn off Sounders.
- The panel is reset to Normal operation mode. Press , then .
User Quick Guidelines for MAGPRO9601 Addressable Fire Alarm Panel
Zone TEST
NOTE: The Messages for running tests in the system are with the lowest priority and they are not displayed automatically from the panel!
Button sequence for ZONE testing:
DISABLE Introducing
NOTE: The DISABLE Messages for events are with high priority but they are not displayed automatically from the panel!
Button sequence for DISABLE introducing: