Product Information

Specifications

  • Model Options: UDTAKIT White, UDTAKITSS Stainless Steel, UDTAKITG Grey
  • Components: Power/Light/Buzzer Module, Reset Module, Pull Cord Module
  • Battery Type: A23 Alkaline Battery 12V

FAQ

  • Q: What should I do if the alarm keeps sounding?
    • A: Check the battery level and replace it if necessary. Ensure proper installation of all components.
  • Q: Can the system be self-installed?
    • A: No, installation should be done by a qualified electrician to ensure compliance and safety.

Information

Assistance Alarm

ESP-UDTAKIT-Disabled-Persons-Toilet-Alarm-Kit-fig-1

ESP-UDTAKIT-Disabled-Persons-Toilet-Alarm-Kit-fig-2

Overview

ESP-UDTAKIT-Disabled-Persons-Toilet-Alarm-Kit-fig-3

  1. Pull cord Module
    • 1st pull handle to be 100mm from floor.
    • 2nd pull handle to be mounted 800/1000mm from floor.
  2. Reset Module
    • Module to be mounted maximum 1200mm from the floor
  3. Input Power, Light and Buzzer Module
    • Activates when the Pull Cord is triggered.
    • Also provides system power input

System designed to comply with care standards BS8300 Installation to be carried out by a qualified electrician.

Wiring Configuration

Kit Wiring Configuration

ESP-UDTAKIT-Disabled-Persons-Toilet-Alarm-Kit-fig-4

Maximum Wiring Configuration

ESP-UDTAKIT-Disabled-Persons-Toilet-Alarm-Kit-fig-5

Operation Guide

For backup battery modules please test/replace the battery a minimum of every 12 months & after any duration the system has been powered directly from the battery.
An audible tone will sound if the battery is missing or low.

ESP-UDTAKIT-Disabled-Persons-Toilet-Alarm-Kit-fig-6

Battery Conditions:

  • Battery level normal
    • (12v-9.6v) Alarm activation for approximately 10 minutes
  • Battery level low
    • (9.6v-6v) Alarm activation for approximately 4 minutes
  • Battery level 6v or below
    • Replace battery
  • Battery Type: A23 Alkaline Battery 12V

Contact

Elite Security Products

  • Unit 7, Target Park, Shawbank Road, Lakeside, Redditch B98 8YN
  • Tel: +44 (0) 1527 51 51 50
  • Fax: +44 (0) 1527 51 51 43
  • www.espuk.com
  • sales@espuk.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals