KLARSTEIN 10032040 DryFy 10 Air Dehumidifier Instruction Manual
- June 5, 2024
- Klarstein
Table of Contents
- KLARSTEIN 10032040 DryFy 10 Air Dehumidifier
- TECHNICAL DATA
- SAFETY INSTRUCTIONS
- INSTALLATION
- PRODUCT DESCRIPTION
- CONTROL PANEL AND KEYS
- OPERATION AND FUNCTIONS
- CARE AND CLEANING
- TROUBLESHOOTING
- DISPOSAL CONSIDERATIONS
- MANUFACTURER & IMPORTER (UK)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KLARSTEIN 10032040 DryFy 10 Air Dehumidifier
Dear Customer,
Congratulations on purchasing this device. Please read the following
instructions carefully and follow them to prevent possible damages. We assume
no liability for damage caused by disregard of the instructions and improper
use. Scan the QR code to get access to the latest user manual and more product
information.
TECHNICAL DATA
Item number | 10032040, 10032662 |
---|---|
Power supply | 220-240 V ~ 50 Hz |
Power consumption | 240 W |
Dehumidifying capacity | 10 L/day (30 °C, RH 80 %) |
Water tank | 1.8 L |
SAFETY INSTRUCTIONS
- Please read the operating instructions carefully before using your dehumidifier for the first time and keep it on a safe floor.
- Never immerse the appliance in water or other liquids.
- Place the unit on a stable flat surface to avoid loud noises and vibrations.
- Never operate the appliance if a cable or connector has been damaged, after appliance malfunction or if the appliance was dropped or otherwise damaged.
- The appliance may only be repaired by qualified personnel, improper repair work can be a source of considerable danger for the users.
- Pull out the power plug before transporting it and/or before cleaning.
- Operate the appliance only at the voltage specified on the rating label.
- The device may not be connected to a power strip with other household appliances.
- Use the appliance only in the household, and only for the purpose, it was developed for.
- Do not operate this unit near heating appliances and flammable or dangerous objects.
- If the dehumidifier is operated in a room with gas-driven devices, so the room must be aired regularly and often.
- Please use the function of the internal drying, if the device is not used for a long time. This will prevent formation of mildew and unpleasant smell inside the unit.
- Do not place heavy objects on the appliance.
- Do not hang curtains or wet clothes in front of the air outlet, this will overload the device.
- The drainage hose may not be installed outdoors at low temperatures.
- To prevent spillage, empty the water tank before relocating the appliance.
- Do not tip the appliance to any side as escaping water could damage the appliance.
- If the supply cord is damaged, it must be replaced by a qualified person to avoid a hazard.
- If you smell the smoke during start-up or if you can see the smoke, immediately disconnect the power plug out and contact your dealer.
- The unit should be installed with a minimum distance of 20 cm from the wall or other obstacles.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory and mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user maintenance shall not be made by children without supervision.
INSTALLATION
- Empty the water tank before turn on the unit.
- During the operation, keep unit closed to the door and windows closed to save energy.
- Make sure no block at air inlet and outlet
- Place the appliance on a stable surface and allow at least 20 cm of space around the appliance and at least 50 cm in the area to allow air to circulate sufficiently.
PRODUCT DESCRIPTION
Front
Back
CONTROL PANEL AND KEYS
Control Panel
Keys and Functions
OPERATION AND FUNCTIONS
Timing off
When the dehumidifier is running, press “TIMER” to start the function, then
press “TIMER” button to set hours, timing range is from 1 to 24hours, it will
increase 1 hour by each press. When time is up to your setting, unit will turn
off. After setting, timer button flashes 5 time for confirmation.
Timing on
When the dehumidifier is in standby state, press “TIMER ” to start the
function, then press “TIMER” button to set hours, When time is up to your
setting, unit will turn on. After setting, timer button flashes 5 time for
confirmation.
Auto dehumidifying mode
If the humidity in the room is above 5 % of the set humidity, the compressor
and fan start. If the humidity in the room is less than 5 % of the set
humidity, the compressor stops and the fan runs again at the preset speed.
When the humidity decreases or increases, the compressor and fan start and
stop alternately. The preset humidity is 50 %.
Cloth dry mode
Under this mode, the unit will work regardless of the room humidity,
compressor works, and fan will work from high speed, fan speed is adjustable.
Drainage manually
- When water tank is full, water-full indicator is on, the unit will stop working, and buzzer will sound 10 times till water is pour off.
- Take out water tank, pour away water.
- Replace the water tank, dehumidifier restarts working. Please install the water tank as the following photo.
Note: Before putting in the water tank, please ensure the float is flexible.
Continuous drainage (optional)
- To connect a water pipe in the back, (inner diameter is 9 mm) water can be drained continuously.
- Please check if the pipe is stably connected with the drainage mouth, or water will flow out.
Note: Water pipe cannot be too long (usually 0.6m), the height cannot surpass the height of drainage mouth, or there will be water leakage.
Anti-frost function
This function will be activated when the ambient temperature falls below 16
°C. The display will show „P1“. It will be activated for a period of 8 minutes
every 38 minutes between 2-12 °C. It will also be activated for a period of 5
minutes every 60 minutes between 12-16 °C.
CARE AND CLEANING
- Turn off this appliance and pull out plug before maintaining or repairing.
- Pull out plug if dehumidifier is not used for long time
- Please do not use benzene, alcohol, gasoline or other chemical reagents to clean unit.
TROUBLESHOOTING
Problem | Possible Cause | Suggested Solution |
---|---|---|
Unit doesn’t work. | Is the power plug connected? | Put the plug in the socket. |
Water tank is full or water tank
is not assembled well.
| Pour away the water in water- tank, and put water tank into the unit.
Operation temperature is too low or too high| Use this dehumidifier under the
environment 5-32 °C.
No outlet air.| Operation temperature or
humidity is too low.
| Under dry environment, dehumidifying effect will be not so obvious.
Is air outlet or air inlet blocked?| Clean the air outlet or air inlet.
No outlet air.| Is filter blocked?| Clean the filters.
Water leakage.| Drainage pipe is not tightly
connected.
| Check the drainage pipe.
Pipe is blocked.| Clean the debris in pipe.
DISPOSAL CONSIDERATIONS
If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service.
MANUFACTURER & IMPORTER (UK)
Manufacturer:
Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.
Importer for Great Britain:
Chal-Tec UK limited
Unit 6 Riverside Business Centre
Brighton Road
Shoreham-by-Sea
BN43 6RE
United Kingdom
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>