VAPOAIR OPAL
10032895

Dear Customer,
Congratulations on purchasing this equipment. Please readthis manual carefully and take care of the following hints toavoid damages. Any failure caused by ignoring the items andcautions mentioned in the instruction manual is not coveredby our warranty and any liability. Scan the QR code to getaccess to the latest user mannual and other information aboutthe product.

KLARSTEIN 10032895 VapoAir Opal Humidifier - QR code

https://use.berlin/10032895

TECHNICAL DATA

Item Number 10032895
Power supply 220-240 V ~ 50/60 Hz
Power 110 W
Water tank capacity 5 L
Evaporation Rate ≥ 300 ml/Stunde

SAFETY INSTRUCTIONS

  • Children over 8 years of age, mentally and physically handicapped persons may only use the device if they have been familiarized in detail with the functions and safety precautions by a supervisor responsible for them. Do not allow children to play with the device. Children from 8 years of age may only clean the device under supervision.
  • Check the voltage on the device plate before use. Only connect the device to sockets that correspond to the voltage of the device.
  • Place the unit on a stable, level surface. Do not place the redness in direct sunlight or near heat sources such as ovens or radiators. Doing so may cause the unit to malfunction.
  • Do not touch the plug with wet hands.
  • If the power cord or plug is damaged, it must be replaced by the manufacturer, an authorized service center or a similarly qualified person.
  • Do not open the housing. The device contains parts that are not accessible to the user. Repairs may only be carried out by qualified specialists.
  • Fill the tank with fresh, distilled or demineralized water. Do not switch on the unit if there is no water in the tank.
  • Do not shake or tilt the unit. Otherwise, the water from the tank may overflow and penetrate inside the unit.
  • If water drips on the unit or penetrates into the unit, immediately unplug the unit and contact a specialist dealer.
  • Never touch the water or components while the unit is running.
  • If there is an unusual smell, turn the unit off, unplug it and have it checked by a specialist dealer.
  • Do not pour water warmer than 40 °C into the tank.
  • Disconnect the plug before cleaning the unit or removing the tank.
  • Never immerse the device and the power cord in water or other liquids.
  • The unit must be cleaned regularly. Please observe the cleaning instructions in this manual.
  • If you are not going to use the unit for a long time, unplug it.
  • Never use this device in rooms where sprays are used or where oxygen is administered.
  • Do not place clothes or towels on the machine.
  • When you move the unit, lift it at the base and not at the water tank.
  • The humidifier is intended for indoor and domestic use only.

Note: Do not use the humidifier if the air in the room is already sufficiently humid (relative humidity of at least 50%). The ideal relative humidity is between 45% and 60%. Excess moisture can be seen in the form of condensation on cold surfaces or cold walls in the room. To measure humidity correctly, use a hygrometer that is available in specialist shops and DIY stores.

PRODUCT OVERVIEW

DISPLAY

KLARSTEIN 10032895 VapoAir Opal Humidifier - Fig 3

Note: The unit can be operated using the control panel buttons on the unit or the buttons on the remote control.

BUTTON FUNCTIONS

Remote control (batteries are not included)

**** Power on/off

Turn on/off NIGHT mode
Turn on/off AUTO mode
Turn on/off BABY mode
Turn on/off HEALTH mode
Turn on/off water tank light
Set timer
Control HEATING and IONIZER function
Set humidity
Control the mist level

Bedienfeld-Tasten

KLARSTEIN 10032895 VapoAir Opal Humidifier - Fig 5

Taste Funktion
ON/OFF Power on/off
MODES To select the different modes
NIGHT Night mode on/off
HUMIDITY Set humidity
TIMER Set timer
DEGERMING Control HEATING and PLASMA function.

OPERATION AND MODES

Note: If no button or symbol is pressed within 15 seconds, the display will turn off automatically. Press any button to turn it back on.

Before first Use

  • For first Operation, put unit in the room temperature for half of an hour before running.
  • Use clear water not over 40 degree C
  • Check the water basin, make sure it is clear.

Getting Started

  1. Place the unit on a flat surface.

  2. When you remove the water tank, you must switch on the child safety lock.

  3. Fill the water into the water tank and then attach the tank cap.

  4. Place the water tank on the base.

  5. Plug the plug into the power outlet.

  6. Press the POWER button, the display turns on and the unit starts in AUTO mode.
    The AUTO mode symbol lights up on the display and the current temperature and humidity is shown. After 15 seconds without further input, the display turns off again.
    Press any button to turn it back on.

  7. Press the MODES button on the unit to select one of the modes.

How to insert the remote control batteries (The batteries are not included in the scope of delivery.)

  1. Flip the remote on its side.
  2. Press the battery release on the bottom edge of the remote.
  3. Grasp the battery socket and pull the battery out.
  4. Insert a lithium battery type CR2025.

KLARSTEIN 10032895 VapoAir Opal Humidifier - Fig 6

Auto Mode
The device determines the optimal humidity by the formula and starts to achieve it at maximum power. WhJen the current humidity less than the table showed humidity, it is in  high speed operation. When the humidity arrived, the machine will be in low speed operation. The device checks the accordance of the temperature level and the humidity level every 1 minute.

Sir temperature in °C Humidity in %
≤19 65
20 60
21 58
22 57
23 55
24 53
25 50
26 48
27 45
28 43
29 40
30 38
31 36
32 35
33 34
34 32
35 31
36 30
37 nd higher 25

Health Mode

  • Press the Health mode button on the remote control. The symbol for warm fog is on. The device runs at high speed and tries to reach an air humidity of 60%.
  • As soon as an air humidity of 60% has been reached, the device runs only at low speed.
  • In Health mode, only the timer function can be used. Humidity and temperature are fixed.
  • The unit checks the humidity every minute.

Baby Mode

  • In this mode, the warm fog and ionizer functions are also activated. The baby mode icon, the warm fog icon and the inonizer icon will appear on the display.
    The device runs at high speed and tries to reach an air humidity of 55%.

  • As soon as an air humidity of 55% has been reached, the device runs only at low speed.

  • In Health mode, only the timer function can be used. Humidity and temperature are fixed.

  • The unit checks the humidity every minute.

Night Mode
Press the night mode button on the remote control. The indicator light on the water tank goes out. After 5 seconds without operation, the display turns off, only the symbol for
the post-mode remains on. Press any button to turn the display back on. Press the night mode button again to turn off the night mode.
Note: If they are in a mode other than night mode, press and hold the night mode button for 3 seconds to turn the water tank light on and off.

Setting the timer
Press the TIMER button, the LED display shows the timer. There are 12 timer settings: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 hours. The timer displays the remaining running time in 1 hour steps. For example, if the timer is set to 12 hours, the LED display shows[11] after one hour. The display shows the current temperature and the rest time alternately at 30-second intervals. To know what time has been set, simply press the timer button. Press the button again to reset the timer.

Heating and ionizer function
Press the button for the heating and plasma function. Warm fog emerges after 10~15 minutes.
The warm fog symbol  appears on the display Press the button again to start the ionizer. The ionizer symbol  appears on the display. Press the button again to stop the warm fog.
After 5~10 minutes cold fog appears again. Press the button again to stop the ionizer.

Setting the fog quantity and display brightness
Stroke the bottom bar to set the mist level from 1-7. When you are in Auto, Baby or Health mode, stroke the bar to exit and switch to manual mode. Brush to the left to reduce the amount of mist and the display brightness. Brush to the right to increase the amount of mist and the display brightness.

Low water warning
If the amount of water in the tank is too low to keep the machine running, the machine stops automatically. The display shows the symbol for low water . Top up the water and the unit starts again after 5 seconds. If you do not top up water within 5 minutes, the unit switches off automatically.

RELATIVE HUMIDITY

The percentage of water mist in a given space with a given air temperature is named as relative humidity, usually marked as %RH, i.e. 45%RH. The air contains water mist more or less. The proportion of water mist to the air varies according to different air temperatures. The higher the temperature, the more water mist inhaled in the air. In the winter, the cold air outside enters the room and becomes warmer by the higher temperature in the room. As a result, the relative humidity decreases. If you want to keep the healthy environmental humidity, we need to increase the mist volume in the air. The humidifier can do that for us. Relative humidity in different environments suitable for people:

  • Bedroom, living room: 45-65%RH
  • Patient’s room: 40-55%RH
  • Room with computer, experiment equipment: 45-60%RH
  • Room with piano: 40-60%RH
  • Museum, exhibition hall, and library: 40-60%RH

CLEANING AND CARE

Note: Always switch off and unplug the unit before cleaning.

  • Use cold boiled water or distilled water.
  • Clean the transducer, water tank and basin unit every week.
  • Change the water in water tank more often to keep it fresh.
  • Make sure to pull out the water from the water tank and dry the water basin before you store the unit unused for a long period of time.
  • Clean the whole unit and make sure that all parts of the unit are dried completely before unused for longer period of time.

How to clean the transducer:

  • Put 5-10 drops of cleaning abluent on the surface of the transducer, wait for 2-5 minutes.
  • Brush off the scale from the surface.
  • Rinse the transducer with clean water.
  • Never use sharp or solid objects for cleaning the transducer

How to clean the Basin unit:

  • Clean the water basin with soft cloth .if there is excess film on the surfaces, then soak the cloth with vinegar and repeat the process.
  • If there is a film in any of the depressions along the basin ,drop a bit of vinegar into depression and clean it out with a brush.
  • Rinse the water basin with clean water.

How to clean the Ceramic Filter System:

  • Clean and activate the ceramic balls after use of 1000 L water regularly.
  • Remove the filter from the tank cover.
  • Put some white vinegar into a glass, soak the filter in the vinegar for about 10 minutes.
  • Remove the filter from the glass and shake it several times.
  • Clean and rinse the filter once again with fresh water.

If you don’t plan to use the humidifier for a long time, remove the filter from the water tank and let it dry thoroughly, then wrap it in protective packaging and keep it next to the humidifier in a cool, dry and dark storage space.

Storage

  • If you are not going to use the humidifier for a long time, make sure that all its parts are dry, including the operating chamber of the sprayer.
  • Do not store the unit with water in the water tank and in the operating chamber of the sprayer.
  • Clean and dry the filter-cartridge before taking it away for storage. Keep the filtercartridge in a cool darkened place.
  • Keep the humidifier away from children in a dry cool place.

TROUBLESHOOTING

Problem Possible Cause Suggested Solution
Power lamp off or does not work Humidifier is not plugged into the power
outlet or loose. Connect power cord to electrical outlet and press power

button
Power lamp is on but no mist| No water in water tank| Fill water into water tank
The mist has a strange odour| A New unit| Take out water tank, open cover, let it stay 12 hours
in cool position
It either has dirty water or the water has been stagnant too long| Clean water tank, fill with clear water
Power light is on, but the machine doesn’t work.| Too much water in the water basin| Remove the water tank. Take a small cup and remove some of the water from the machine’s water basin. Reinsert the water tank and make sure that it sits properly
The volume of spray mist is too low| Too much mineral scale in the water basin| Clean transducer
Water is too dirty or water kept too long in the tank| Clean water tank and refill with clean water
Abnormal noise| Vibration in the water tank because the water level too low| Fill the water tank
Machine is on and unstable surface| Move the unit to a stable flat surface
Spray mist is coming out of the area around the jets.| There are gaps between the nozzle and water tank| Dip the nozzle in water for a while, clean it with a damp cloth and put it back to the tank.

The following is not considered faulty operation:

  • If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to clean the filter more often or use softer water.
  • If you stand very close to the humidifier, you will hear the gurgling sound of water, this is normal.
  • The machine operate very quietly but it is not completely silent. Noise levels less than 35 dB is considered normal.

DISPOSAL CONSIDERATIONS

If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service.
This product contains batteries. If there is a legal regulation for the disposal of batteries in your country, the batteries must not be disposed of with household waste. Find out about local regulations for disposing of batteries. By disposing of them in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences.

MANUFACTURER & IMPORTER (UK)

Manufacturer:
Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.

Importer for Great Britain:
Chal-Tec UK limited
Unit 6 Riverside Business Centre
Brighton Road
Shoreham-by-Sea
BN43 6RE
United Kingdom