HRSTAR G2E140-AG02-05 New Authentic German Ebmpapst Fan Instruction Manual
- June 13, 2024
- HRSTAR
Table of Contents
G2E140-AG02-05
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2
D-74673 Mulfingen
Phone +49 (0) 7938 81-0
Fax +49 (0) 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
SAFETY REGULATIONS AND INFORMATION
Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or danger to
persons.
These operating instructions are to be regarded as part of the device. The
device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform about
potential dangers and their prevention.
1.1 Hazard levels for warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified actions are
not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can lead to
property damage.
1.2 Staff qualifications
The device may only be transported, unpacked, installed, operated, maintained
and otherwise used by suitably qualified, trained and authorized technical
staff.
Only authorized specialists are permitted to install the device, to carry out
a test run and to perform work on the electrical installation.
1.3 Basic safety rules
The safety hazards associated with the device must be assessed again following
installation in the final product.
The locally applicable industrial safety regulations are always to be observed
when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area increases the
risk of accidents.
Note the following when working on the device:
⇒ Do not perform any modifications, additions or conversions on the device
without the approval of ebm-papst.
1.4 Voltage
⇒ Check the device’s electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
⇒ Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a rubber mat.
CAUTION
Electric charge on capacitor after device is switched off Electric shock, risk
of injury
→ Discharge the capacitors before working on the device.
WARNING
Live terminals and connections even with device switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles before
opening the device.
CAUTION
In the event of a fault, the rotor and the impeller will be energized
The rotor and the impeller have basic insulation.
→ Do not touch the rotor and impeller once installed.
CAUTION
The motor restarts automatically when operating voltage is applied, e.g. after
a power failure.
Risk of injury
→ Keep out of the device’s danger zone.
→ When working on the device, switch off the line voltage and ensure that it
cannot be switched back on.
→ Wait until the device comes to a stop.
1.5 Safety and protective features
DANGER
Guard missing and guard not functioning
Without a guard, hands may become caught up in the device during operation for
example, resulting in serious injury. Loose parts or items of clothing could
be drawn in.
→ The device is a built-in component. As the owner, you are responsible for
ensuring that the device is adequately safeguarded.# Operate the device only
with a fixed protective device and guard grill.
→ Stop the device immediately if a protective device is found to be missing or
ineffective.
1.6 Mechanical movement
DANGER
Rotating device
Risk of injury to body parts coming into contact with the rotor or the
impeller.
→ Secure the device against accidental contact.
→ Before working on the system/machine, wait until all parts have come to a
standstill.
WARNING
Rotating device
Long hair and dangling items of clothing, jewelry and the like can become
entangled and be pulled into the device. Injuries can result.
→ Do not wear any loose-fitting or dangling clothing or jewelry while working
on rotating parts.
→ Protect long hair with a cap.
1.7 Emissions
WARNING
Depending on the installation and operating conditions, the sound pressure
level may exceed 70 dB(A).
Risk of noise-induced hearing loss
→ Take appropriate technical safety measures.
→ Protect operating personnel with appropriate safety equipment such as
hearing protection.
→ Also observe the requirements of local agencies.
1.8 Hot surface
CAUTION
High temperature on motor housing
Risk of burns
→ Ensure sufficient protection against accidental contact.
1.9 Transport
NOTE
Transporting the device
→ Transport the device in its original packaging only.
→ Secure the device so it cannot slip, e.g. by using a lashing strip.
1.10 Storage
⇒ Store the device, partially or fully assembled, in a dry place, protected
against the weather and free from vibration, in the original packaging in a
clean environment.
⇒ Protect the device against environmental effects and dirt until final
installation.
⇒ We recommend storing the device for no longer than one year in order to
guarantee trouble-free operation and the longest possible service life.
⇒ Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.
⇒ Maintain the storage temperature, see Chapter 3.5 Transport and storage
conditions.
INTENDED USE
The device is exclusively designed as a built-in device for conveying air
according to its technical data.
Any other usage above and beyond this does not conform with the intended
purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical and thermal
stresses that can arise from this product. This applies for the entire service
life of the equipment in which this product is installed.
Intended use also includes
- Conveying air at an ambient air pressure between 800 mbar and 1050 mbar.
- Using the device within the permitted ambient temperature range; see Chapter 3.5 Transport and storage conditions and Chapter 3.2 Nominal data.
- Operating the device with all protective devices.
- Following the operating instructions.
Improper use
In particular, operating the device in the following ways is prohibited and
could be hazardous:
- Operating the device in an unbalanced state, e.g. due to dirt deposits or ice formation.
- Resonant operation, operation with severe vibration. This also includes vibration transmitted to the fan from the customer installation.
- Operation in medical equipment with a life-sustaining or life-support function.
- Conveying solids in the flow medium.
- Painting the device
- Connections (e.g. screws) coming loose during operation.
- Conveying air that contains abrasive particles.
- Conveying highly corrosive air, e.g. salt spray. Exception: devices designed for salt spray and correspondingly protected.
- Conveying air with high dust content, e.g. suctioning off sawdust.
- Operating the device close to flammable materials or components.
- Operating the device in an explosive atmosphere.
- Using the device as a safety component or to perform safety-related functions.
- Operation with completely or partially disassembled or manipulated protective devices.
- In addition, all applications not listed among the intended uses.
TECHNICAL DATA
3.1 Product drawing
All dimensions in mm.
- brown + capacitor
- N (black + capacitor)
- L (blue)
- Flat plug 6.3 x 0.8 (PE)
3.2 Nominal data
Motor | M2E068-DF |
---|---|
Phase | 1~ |
Nominal voltage / VAC | 230 |
Frequency / Hz | 50 |
Method of obtaining data | ml |
Valid for approval/ standard | CE |
Speed (rpm) / min-1 | 2000 |
Power consumption / W | 200 |
Current draw / A | 0.88 |
Capacitor / µF | 4 |
Capacitor voltage / VDB | 400 |
Capacitor standard | S2 (CE) |
Min. back pressure / Pa | 100 |
Min. ambient temperature / °C | -25 |
Max. ambient temperature / °C | 50 |
Starting current / A | 1.2 |
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment Subject to change
3.3 Technical description
Weight | 3.65 kg |
---|---|
Size | 140 mm |
Motor size | 68 |
Rotor surface | Painted black |
Impeller material | Sheet aluminum |
Housing material | Die-cast aluminum |
Direction of rotation | Counterclockwise, viewed toward rotor |
Degree of protection | IP20 |
Insulation class | “F” |
Moisture (F) / Environmental (H) protection class | HO – dry environment |
Installation position | Any |
Condensation drainage holes | None, open rotor |
Mode | 51 |
Motor bearing | Ball bearing |
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) |
<0.75 mA
Electrical hookup| Terminal strip; Via terminals, capacitor connected
Motor protection| Thermal overload protector (TOP) internally connected
Protection class| I (with customer connection of protective earth)
Motor capacitor according to EN 602521 in safety protection class| S2
Conformity with standards| EN 60335-1; CE; UKCA
Approval| CCC; EAC
With regard to cyclic speed loads, note that the rotating parts of the device
are designed for a maximum of one million load cycles. If you have special
questions, consult ebm-papst for
support.
⇒ Use the device in accordance with its degree of protection.
Information on surface quality
The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over the
course of time. The product is to be protected against UV radiation to prevent
the formation of patches and fading. Changes in color are not a reason for
complaint and are not covered by the warranty. UV radiation in the frequency
range and the intensity of natural solar radiation has no effect on the
technical properties of the products.
3.4 Mounting data
Further mounting data can be taken from the product drawing or Chapter
4.1 Mechanical connection as required.
Strength class of screws | 8.8 |
---|
For screw clearance, see Chapter 3.1 Product drawing
⇒ Secure the screws against unintentional loosening (e.g. use selflocking
screws).
3.5 Transport and storage conditions
Max. permitted ambient temp. for motor (transport/ storage) | + 80 °C |
---|---|
Min. permitted ambient temp. for motor (transport/ storage) | – 40 °C |
CONNECTION AND STARTUP
4.1 Mechanical connection
CAUTION
Cutting and crushing hazard when removing blower from packaging
→ Carefully remove the blower from its packaging, touching only the housing.
Strictly avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
NOTE
Damage to the device from vibration
Bearing damage, shorter service life
→ The fan must not be subjected to force or excessive vibration from sections
of the installation.
→ If the fan is connected to air ducts, the connection should be isolated from
vibration, e.g. using compensators or similar elements.
→ Ensure stress-free attachment of the fan to the substructure.
⇒ Check the device for transport damage. Damaged devices are not to be
installed.
⇒ Install the undamaged device in accordance with your application.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of installation
until all fastening screws have been tightened.
- The fan must not be strained on fastening.
4.2 Electrical connection
DANGER
Voltage on the device
Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.
DANGER
Faulty insulation
Risk of fatal injury from electric shock
→ Use only cables that meet the specified installation regulations for
voltage, current, insulation material, capacity, etc.
→ Route cables so that they cannot be touched by any rotating parts.
CAUTION
Voltage
The device is a built-in component and has no disconnecting switch.
→ Only connect the device to circuits that can be switched off with an all-
pole disconnection switch.
→ When working on the device, secure the system/ machine in which the device
is installed so as to prevent it from being switched back on.
CAUTION
Electric shock
Voltage on metal part
→ Use the device only with the cable guard and terminal box intended for it.
NOTE
Water ingress into wires or cables
Water ingress at the customer end of the cable can damage the device.
→ Make sure the end of the cable is connected in a dry environment.
Only connect the device to circuits that can be switched off with an all-pole
disconnection switch.
4.2.1 Requirements
⇒ Check whether the information on the nameplate matches the connection data.
⇒ If the motor run capacitor was not installed by ebm-papst, check whether the
information on the motor run capacitor matches the information on the
nameplate.
⇒ Before connecting the device, make sure the power supply matches the device
voltage.
⇒ Only use cables designed for the current level indicated on the nameplate.
For determining the cross-section, note the sizing criteria according to EN
61800-5-1. The protective earth must have a cross-section equal to or greater
than that of the phase conductor. We recommend the use of 105 °C cables.
Ensure that the minimum cable cross-section is at least AWG 26 / 0.13 mm².
Protective earth contact resistance according to EN 60335
Compliance with the resistance specifications according to EN 60335 for the
protective earth connection circuit must be verified in the end application.
Depending on the installation situation, it may be necessary to connect an
additional protective earth conductor by way of the extra protective earth
terminal provided on the device.
4.2.2 Voltage control
NOTE
Current overshoots may occur if speed control is implemented by transformers
or electronic voltage regulators (e.g. phase control). Depending on the type
of installation of the device,
noise and vibration may also occur in the case of phase control. Vibration can
lead to bearing damage and thus premature failure.
Heating-up of the motor when using voltage control must be checked by the
customer following installation in the end device.
4.2.3 Variable frequency drive
Please use a variable frequency drive only after consultation with ebmpapst.
For operation with variable frequency drives, install sinusoidal filters that
work on all poles (phase-phase and phase-ground) between the drive and the
motor.
During operation with variable frequency drives, an all-pole sine filter
protects the motor against high-voltage transients that can destroy the coil
insulation system, and against harmful bearing currents.
Heating-up of the motor when using a variable frequency drive must be checked
by the customer following installation in the end device.
4.3 Plug connection
4.3.1 Making supply connections
⇒ Check your connector’s pin assignment.
⇒ Connect the built-in connector with the mating connector.
⇒ Ensure that the connector is properly engaged.
4.4 Connection via terminal strip
4.4.1 Connecting wires to terminals
WARNING
Live terminals and connections even with device switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles before
opening the device.
⇒ Insert the wires into the terminals, see Chapter 4.5 Connection diagram.
4.5 Connection diagram
L blue
N black
4.6 Checking connections
⇒ Ensure isolation from supply (all phases).
⇒ Make sure a restart is impossible
⇒ Check the cables for proper fit.
4.7 Switching on the device
The device may only be switched on if it has been installed properly and in
accordance with its intended use, including the required safety mechanisms and
professional electrical hookup. This also applies for devices which have
already been equipped with plugs and terminals or similar connectors by the
customer.
WARNING
Hot motor housing
Risk of fire
→ Ensure that no combustible or flammable materials are located close to the
blower.
⇒ Before switching on, check the device for visible external damage and make
sure the protective devices are functional.
⇒ Check the fan’s air flow paths for foreign matter and remove any foreign
matter found.
⇒ Apply the nominal supply voltage.
NOTE
Damage to the device from vibration
Bearing damage, shorter service life
→ Low-vibration operation of the fan must be ensured over the entire speed
control range.
→ Severe vibration can arise for instance from inexpert handling,
transportation damage and resultant imbalance or be caused by component or
structural resonance.
→ Speed ranges with excessively high vibration levels and possibly resonant
frequencies must be determined in the course of fan commissioning.
→ Either run through the resonant range as quickly as possible with speed
control or find another remedy.
→ Operation with excessively high vibration levels can lead to premature
failure.
4.8 Switching off the device
⇒ Disconnect the device from the power supply at the supply line’s main
switch.
MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES
Do not perform any repairs on your device. Send the device to ebmpapst for repair or replacement.
WARNING
Live terminals and connections even with device switched off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles before
opening the device.
CAUTION
Electric charge on capacitor after device is switched off Electric shock, risk
of injury
→ Discharge the capacitors before working on the device.
CAUTION
The motor restarts automatically when operating voltage is applied, e.g. after
a power failure.
Risk of injury
→ Keep out of the device’s danger zone.
→ When working on the device, switch off the line voltage and ensure that it
cannot be switched back on.
→ Wait until the device comes to a stop.
If the device is out of use for some time, e.g. when in storage, we recommend
switching it on for at least two hours to allow any condensation to evaporate
and to move the bearings.
Malfunction/fault | Possible cause | Possible remedy |
---|---|---|
Impeller not running smoothly | Imbalance in rotating parts | Clean the device; |
replace it if imbalance persists after cleaning. Make sure no weight clips are
removed during cleaning.
Motor not turning| Mechanical blockage| Switch off, isolate from supply and
remove mechanical blockage.
| Line voltage faulty| Check line voltage, restore power supply.
| Faulty connection| Isolate from supply, correct connection; see connection
diagram.
| Thermal overload protector activated| Allow motor to cool off, locate and
rectify cause of error,
release restart lockout if necessary
| Impermissible point of operation| Check point of operation
Motor overtemperature| Ambient temperature too high| Reduce ambient
temperature if possible
| Deficient cooling| Improve cooling
In the event of further malfunctions, contact ebm-papst.
5.1 Cleaning
To ensure a long service life, check the fans regularly for proper operation
and soiling. The frequency of checking is to be adapted accordingly depending
on the degree of soiling.
DANGER
Risk of injury from rotating fan.
→ Only clean when not in motion. Interrupt the power supply, secure against
renewed switch-on. Secure against start-up, prevent air flow.
⇒ Dirt deposits on the motor housing can cause overheating of the motor.
⇒ Soiling of the impeller can cause vibration that will shorten the service
life of the fan.
⇒ Severe vibration can destroy the fan.
⇒ In such cases, switch off the fan immediately and clean it.
⇒ The preferred method of cleaning is dry cleaning, e.g. using compressed air.
⇒ Do not use aggressive cleaning agents!
NOTE
Damage to the device during cleaning
Malfunction possible
→ Do not clean the device using a water jet or high-pressure cleaner.
→ Do not use any acid, alkali or solvent-basedcleaning agents.
→ Do not use any pointed or sharp-edged objects for cleaning
⇒ Completely remove any cleaning agents used.
⇒ If severe corrosion is visible on load-bearing or rotating parts, switch off
the device immediately and replace it.
⇒ Repair of load-bearing or rotating parts is not permitted!
⇒ Operate the fan for 2 hours at maximum speed so that any water that has
ingressed can evaporate.
⇒ If cleaning does not eliminate vibrations, the fan may need to be
rebalanced. To have it rebalanced, contact ebm-papst.
⇒ The fan is equipped with maintenance-free ball bearings. The lifetime
lubrication of the ball bearings is designed for a service life of 40,000
hours.
⇒ If bearing replacement is necessary after that period, contact ebmpapst.
⇒ Adapt the maintenance intervals to the actual level of dust exposure.
5.2 Safety inspection
What to check | How to check | How often | What action? |
---|---|---|---|
Contact protection cover for intactness or damage | Visual inspection | At least | |
every 6 months | Repair or replacement of |
device
Device for damage to blades and housing| Visual inspection| At least every 6
months| Replacement of device
Fastening the cables| Visual inspection| At least every 6 months| Fasten
Insulation of cables for
damage| Visual inspection| At least every 6 months| Replace cables
Abnormal bearing noise| acoustic| At least every 6 months| Replace device
5.3 Disposal
For ebm-papst, environmental protection and resource preservation are top
priority corporate goals.
ebm-papst operates an environmental management system which is certified in
accordance with ISO 14001 and rigorously implemented around the world on the
basis of German standards.
Right from the development stage, ecological design, technical safety and
health protection are fixed criteria.
The following section contains recommendations for ecological disposal of the
product and its components.
5.3.1 Country-specific legal requirements
NOTE
Country-specific legal requirements
Always observe the applicable country-specific legal regulations with regard
to the disposal of products or waste occurring in the various phases of the
life cycle. The corresponding disposal standards are also to be heeded.
5.3.2 Disassembly
Disassembly of the product must be performed or supervised by qualified
personnel with the appropriate technical knowledge.
The product is to be disassembled into suitable components for disposal
employing standard procedures for motors.
WARNING
Heavy parts of the product may drop off. Some of the product components are
heavy. These components could drop off during disassembly.
This can result in fatal or serious injury and material damage.
→ Secure components before unfastening to stop them falling.
5.3.3 Component disposal
The products are mostly made of steel, copper, aluminum and plastic.
Metallic materials are generally considered to be fully recyclable.
Separate the components for recycling into the following categories:
- Steel and iron
- Aluminum
- Non-ferrous metal, e.g. motor windings
- Plastics, particularly with brominated flame retardants, in accordance with marking
- Insulating materials
- Cables and wires
- Electronic scrap, e.g. circuit boards
Only ferrite magnets and not rare earth magnets are used in external rotor
motors from ebm-papst Mulfingen GmbH & Co. KG.
⇒ Ferrite magnets can be disposed of in the same way as normal iron and steel.
Electrical insulating materials on the product, in cables and wires are made
of similar materials and are therefore to be treated in the same manner.
The materials concerned are as follows:
- Miscellaneous insulators used in the terminal box
- Power cables
- Cables for internal wiring
- Electrolytic capacitors
Dispose of electronic components employing the proper procedures for
electronic scrap.
→ Please contact ebm-papst for any other questions on disposal.
Item no. 11283-5-9970 · ENU · Change 260699
Approved 2022-06-23 · Page 11 / 11
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 ·
D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 ·
info1@de.ebmpapst.com ·
www.ebmpapst.com
Downloaded from Arrow.com.
References
- ebm-papst – energy-saving fans and motors from the world market leader – engineering a better life
- ebm-papst – energy-saving fans and motors from the world market leader – engineering a better life
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>