Congratulations on the purchase of this Beamz product. Please read this manual
thoroughly prior to using the product in order to benefit fully from all
features.
Read the manual prior to using the product. Follow the instructions in order
not to invalidate the warranty. Take all precautions to avoid fire and/or
electrical shock. Repairs must only be carried out by a qualified technician
in order to avoid electrical shock. Keep the manual for future reference.
– Prior to using the product, please ask for advice from a specialist. When
the unit is switched on for the first time, some smell may occur. This is
normal and will disappear after a while.
– The unit contains voltage carrying parts. Therefore do NOT open the housing.
– Do not place metal objects or pour liquids into the product. This may cause
electrical shock and malfunction.
– Do not place the product near heat sources such as radiators, etc. Do not
place the unit on a vibrating surface. Do not cover the ventilation holes.
– The product is not suitable for continuous use.
– Be careful with the mains lead and do not damage it. A faulty or damaged
mains lead can cause electrical shock and malfunction.
– When unplugging the product from a mains outlet, always pull the plug, never
the lead.
– Do not plug or unplug the unit with wet hands. – If the plug and/or the
mains lead are damaged, they need to be replaced by a qualified technician.
– If the product is damaged to such an extent that internal parts are visible,
do NOT plug the unit into a mains outlet and DO NOT switch the product on.
Contact your dealer. Do NOT connect the product to a rheostat or dimmer.
– To avoid fire and shock hazards, do not expose the product to rain and
moisture.
– All repairs should be carried out by a qualified technician only.
– Connect the product to an earthed mains outlet (220240Vac/50Hz) protected by
a 10-16A fuse.
– During a thunderstorm or if the product will not be used for a longer period
of time, unplug it from the mains. The rule is: Unplug it from the mains when
not in use.
– If the product has not been used for a longer period of time, condensation
may occur. Let the unit reach room temperature before you switch it on.
– Never use the product in humid rooms or outdoors.
– During operation, the housing becomes very hot. Do not touch it during
operation and immediately after.
– To prevent accidents in companies, you must follow the application
guidelines and follow the instructions.
– Secure the product with an extra safety chain if the unit is ceiling mount.
Use a truss system with clamps. Make sure nobody stands in the mounting area.
Mount the effect at least 50cm away from inflammable material and leave at
least 1-meter space on every side to ensure sufficient cooling.
– This product contains high-intensity LEDs. Do not look into the LED light to
prevent damage to your eyes.
– Do not repeatedly switch the product on and off. This shortens the lifetime.
– Keep the unit out of the reach of children. Do not leave the unit
unattended.
– Do not use cleaning sprays to clean switches. The residues of these sprays
cause deposits of dust and grease. In case of malfunction, always seek advice
from a specialist.
– Only operate the product with clean hands.
– Do not force the controls.
– If the product has fallen, always have it checked by a qualified technician
before you switch the product on again.
– Do not use chemicals to clean the unit. They damage the varnish. Only clean
the product with a dry cloth.
– Keep away from electronic equipment that may cause interference.
– Only use original spares for repairs, otherwise serious damage and/or
dangerous radiation may occur.
– Switch the product off prior to unplugging it from the mains and/or other
equipment. Unplug all leads and cables prior to moving the product.
– Make sure that the mains lead cannot be damaged when people walk on it.
Check the mains lead before every use for damages and faults!
– The mains voltage is 220-240Vac/50Hz. Check if the power outlet match. If
you travel, make sure that the mains voltage of the country is suitable for
this product.
– Keep the original packing material so that you can transport the product in
safe conditions
This mark attracts the attention of the user to high voltages that are
present inside the housing and that are of sufficient magnitude to cause a
shock hazard.
This mark attracts the attention of the user to important instructions
that are contained in the manual and that he should read and adhere to.
DO NOT LOOK DIRECTLY INTO THE LENS. This can damage your eyes. Persons
who are subject to epileptic attacks should be aware of the effects that this
light effect may have on them.
The product has been certified CE. It is prohibited to make any changes to the
product. They would invalidate the CE certificate and their guarantee!
NOTE: To make sure that the unit will function normally, it must be used
in rooms with a temperature between 5°C/41°F and 35°C/95°F.
Electric products must not be put into household waste. Please bring them to a
recycling centre. Ask your local authorities or your dealer about the way to
proceed. The specifications are typical. The actual values can slightly change
from one unit to the other. Specifications can be changed without prior
notice.
Do not attempt to make any repairs yourself. This would invalidate your
warranty. Do not make any changes to the product. This would also invalidate
your warranty. The warranty is not applicable in case of accidents or damages
caused by inappropriate use or disrespect of the warnings contained in this
manual. Beamz cannot be held responsible for personal injuries caused by the
disrespect of the safety recommendations and warnings. This is also applicable
to all damages in whatever form.
UNPACKING INSTRUCTION
CAUTION! Immediately upon receiving the product, carefully unpack the
carton, check the contents to ensure that all parts are present, and have been
received in good condition. Notify the shipper immediately and retain the
packing material for inspection if any parts appear damaged from shipping or
the package itself shows signs of mishandling. Save the package and all
packing materials. In the event that the product must be returned to the
factory, it is important that the product be returned to the original factory
box and packing.
If the device has been exposed to drastic temperature fluctuation (e.g. after
transportation), do not switch it on immediately. The arising condensation
water might damage your device. Leave the device switched off until it has
reached room temperature.
IP 65
This device is protected against dirt and spray water (IP65) and thus is
intended for professional applications outdoors.
WARNING: This unit is not intended for underwater use! Use only the
original cables both for the power supply and for the signal connections. Make
certain that the screw connections of the cable plugs are intact and always
closed firmly and that there are no foreign bodies such as dust or dirt in the
threads.
POWERSUPPLY
The label on the backside of the product is indicated on this type of power
supply must be connected. Check that the mains voltage corresponds to this,
all other voltages than specified, the light effect can be irreparably
damaged. The product must also be directly connected to the mains and may be
used. No dimmer or adjustable power supply.
**** Always connect the device to a protected circuit (circuit breaker or
fuse). Make sure the device has an appropriate electrical ground to avoid the
risk of electrocution or fire.
INSTALLATION
| CAUTION: Please consider the respective national norms during the
installation! The installation must only be carried out by an authorized
employee or dealer!|
---|---|---
Attention:
- The installation of the product has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harmful deformation.
- The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
- Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging, and servicing.
- The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before taking them into operation for the first time and after changes before taking them into operation another time.
- The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled person once a year.
- The fixture should be installed in the position where persons cannot reach and where persons may walk by or be seated.
| CAUTION: When installing the device, make sure there is no higher
inflammable material (decoration articles, etc.) in between a distance of min
20inch / 0.5 meter.|
---|---|---
DISPLAY
The control board offers several features: you can simply set the starting
address, run the pre-programmed program or make a reset. The main menu is
accessed by pressing the Mode button and browsing through the submenu by
pressing Up or Down.
Press the Enter button in order to select the desired menu.
You can change the selection by pressing Up or Down. Confirm every
selection by pressing the Enter button.
You can leave every mode by pressing the Mode button. The functions
provided are described later in this manual.
DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are connected. If you use a controller with 5 pin DMX connection you will need to use a 5-pin to 3-pin adapter.
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal (+) into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.
MASTER/SLAVE OPERATION
The master/slave operation enables several same units can be controlled by one
“master” unit.
Connect the first unit “DMX OUT” socket with the second unit “DMX IN”, using a
3pin DMX Cable. Repeat this process with the third, fourth, etc., or see the
above section “DMX-512 connection”. Choose the unit that will control all
others and set this in master mode via the display. The other units that must
react to the master, you must set in slave-mode. The “Slave” will
synchronously follow the “Master”.
Noted: Any unit can be the “Master” or “Slave”.
REMOTE CONTROLLER
BLACK OUT Mode
Press < BLACK OUT> off existing modes. Press < BLACK OUT> to return
the last modes.
AUTO Mode
Automatic mode will enable you to run the automatic programs on the product.
To turn on Automatic mode:
- Press < AUTO> on the remote controller.
- Press < +> or < –> to choose between the different auto programs.
STROBE Mode
To adjust the strobe speed of the automatic program
- Press < STROBE> on the remote controller.
- Press < +> or < –> to either increase or decrease the speed of the program.
- Press < STROBE> again to turn off the strobe.
SPEED Mode
To adjust the speed of the automatic program.
- Press < SPEED> on the remote controller.
- Press < +> or < –> to either increase or decrease the speed of the program.
DMX / % Mode
To enable DMX or disallow DMX on the product.
Press < DMX> on the remote controller, and the product work on the DMX
control modes.
MANUAL Mode
- Press < MANUAL> on the remote controller.
- Press < R>,
, or < W> (red, green, blue or white) to choose your colour. - Press again < R>,
, or < W > (red, green, blue or white) to close your colour. - Press < +> or < –> to either increase or decrease the percentage of each color.
FADE/UNIT Mode
To adjust the FADE speed of the automatic program and the manual mode.
- Press < FADE> on the remote controller.
- Press < FADE> again to turn off the Fade mode.
NUMBER 1~9
To adjust the brightness value of the automatic program and Manual Mode.
Press digit < 1> to < 9> to change different brightness on the device.
**** The remote control is supplied with a battery inserted. An insulating
foil between the battery and the battery contacts prevents the battery from
being discharged during storage. Prior to the first operation remove the foil
from the battery support on the rear side of the remote control. Otherwise,
the operation of the remote control is not possible.
If the range of the remote control decreases, replace the battery. For this purpose, on the rear side of the remote control press, the small bar with the groove to the right (1) and at the same time remove the battery support (2). For operation, one 3 V button cell type CR 2025 is required. When inserting, pay attention that the positive pole.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surroundings can cause a greater accumulation of dirt on the unit’s optics.
- Make sure the area below the installation place is free from unwanted persons during servicing.
- Housings, fixations, and installation spots( ceiling, truss, suspensions) should be totally free from any deformation.
- The main cables must be in impeccable condition and should be replaced immediately when even a small problem is detected.
- In order to protect the fixture from overheating the cooling fans (if any) and ventilation openings should be cleaned monthly.
- The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
- Clean with a soft cloth using normal glass cleaning fluid.
- Always dry the parts carefully.
- Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
ATTENTION: We strongly recommend internal cleaning be carried out by qualified workers!
MENU
Mode | Programming | Description | |
---|---|---|---|
DMX mode | Addr | 9CH | d001-d512 |
5CH
4CH
3CH
2CH
Static colors| Stat| S 01-24| Static colors
Auto| Auto| Au 1-2| Auto program
Speed| SPEE| SP 1-9| Speed
Edit color| Colo| r000-255| Red (0-100%)
g000-255| Green (0-100%)
b000-255| Blue (0-100%)
U000-255| White (0-100%)
Color temperature| tEMP| 2700| 2700K
3200| 3200K
4300| 4300K
5600| 5600K
6500| 6500K
8000| 8000K
Dimming| DIMM| dI1-dI9| Master dimming
Slave| SLAV| Slave| Slave
Infrared| info| on/oFF| Enable or Disenable IR remote
DMX CHANNELS
2 Channels
Channel | Function | Value | Description |
---|---|---|---|
1 | Master dimming | 000-255 | Master dimming (0-100%) |
2 | Colour macro | 000-009 | No function |
010-019 | Red | ||
020-029 | Green | ||
030-039 | Blue | ||
040-049 | White | ||
050-059 | Yellow | ||
060-069 | Magenta | ||
070-079 | Cyan | ||
080-089 | Dark orange | ||
090-099 | Green-yellow | ||
100-109 | Salmon | ||
110-119 | Turquoise | ||
120-129 | Light Green | ||
130-139 | Orange | ||
140-149 | Straw | ||
150-159 | Lavender | ||
160-169 | Light blue | ||
170-179 | Dark blue | ||
180-255 | Pink |
3 Channels
Channel | Function | Value | Description |
---|---|---|---|
1 | Colour | 000-255 | Red 0-100% |
2 | 000-255 | Green 0-100% | |
3 | 000-255 | Blue 0-100% |
4 Channels
Channel | Function | Value | Description |
---|---|---|---|
1 | Colour | 000-255 | Red 0-100% |
2 | 000-255 | Green 0-100% | |
3 | 000-255 | Blue 0-100% | |
4 | 000-255 | White 0-100% |
5 Channels
Channel | Function | Value | Description |
---|---|---|---|
1 | Master dimming | 000-255 | (0-100%) |
2 | Strobe | 000-255 | Stroboscope (Rate 0-100%) 0-20/ Second |
3 | Colour macro | 000-009 | No function |
010-019 | Red | ||
020-029 | Green | ||
030-039 | Blue | ||
040-049 | White | ||
050-059 | Yellow | ||
060-069 | Magenta | ||
070-079 | Cyan | ||
080-089 | Dark orange | ||
090-099 | Green-yellow | ||
100-109 | Salmon | ||
110-119 | Turquoise | ||
120-129 | Light Green | ||
130-139 | Orange | ||
140-149 | Straw | ||
150-159 | Lavender | ||
160-169 | Light blue | ||
170-179 | Dark blue | ||
180-255 | Pink | ||
4 | Program | 000-009 | No function |
010-129 | Color blending (rate) | ||
130-255 | Color change (rate) | ||
5 | Temp | 000-009 | No function |
010-049 | White2700k | ||
050-089 | White3200k | ||
090-129 | White4300k | ||
130-169 | White5600k | ||
170-209 | White6500k | ||
210-255 | White8000k |
9 Channels
Channel | Function | Value | Description |
---|---|---|---|
1 | Master dimming | 000-255 | Dimmer 0-100% |
2 | Strobe | 000-255 | Stroboscope (Rate 0-100%) 0-20/ Second |
3 | Red | 000-255 | Red 0-100% |
4 | Green | 000-255 | Green 0-100% |
5 | Blue | 000-255 | Blue 0-100% |
6 | White | 000-255 | White 0-100% |
7 | Colour macro | 000-009 | No function |
010-019 | Red | ||
020-029 | Green | ||
030-039 | Blue | ||
040-049 | White | ||
050-059 | Yellow | ||
060-069 | Magenta | ||
070-079 | Cyan | ||
080-089 | Dark orange | ||
090-099 | Green-yellow | ||
100-109 | Salmon | ||
110-119 | Turquoise | ||
120-129 | Light Green | ||
130-139 | Orange | ||
140-149 | Straw | ||
150-159 | Lavender | ||
160-169 | Light blue | ||
170-179 | Dark blue | ||
180-255 | Pink | ||
8 | Program | 000-009 | No function |
010-129 | Color blending (rate) | ||
130-255 | Color change (rate) | ||
9 | Temp | 000-009 | No function |
010-049 | White2700k | ||
050-089 | White3200k | ||
090-129 | White4300k | ||
130-169 | White5600k | ||
170-209 | White6500k | ||
210-255 | White8000k |
TECHNICAL SPECIFICATION
Rated voltage | AC100~240V 50/60Hz |
---|---|
Rated power | 160W |
LED | 18x12W RGBW 4-in-1 |
Fuse | T3A |
DMX Channels | 2 / 3 / 4 / 5 / 9 Channels |
Function | DMX, Auto, and Master-Slave. |
Dimensions per unit | 265 x 280 x 220mm |
Weight (per unit) | 4.85kg |
Design and product specifications are subject to change without prior notice.
The products referred to in this manual conform to the European Community
Directives to which they are subject:
- Low Voltage (LVD) 2014/35/EU
- Electromagnetic Compatibility (EMC) 2014/30/EU
- Restriction of Hazardous Substances (RoHS) 2011/65/EU
Specifications and design are subject to change without prior notice.
www.tronios.com
Copyright © 2021 by TRONIOS the Netherlands
References
- Samen zijn we open. Samen staan we sterk. - Stichting Open
- Samen zijn we open. Samen staan we sterk. - Stichting Open
- Sound & Light distributor - Tronios.com
- Homepage - Wecycle
- Homepage - Wecycle
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>