SAFETY INSTRUCTIONS

WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with care for future reference It contains important information about the installation, usage and maintenance of the unit

  • Unpackand check carefully that there is no transportation damage before using the unit
  • Please read these instructions carefully and follow the instructions
  • Observe all safety warnings. Never remove safety warnings or other information from the equipment
  • Besurethat noventilation slots are blocked: otherwise the unit will overheated

CAUTION: Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the power values match. If the included power cord or power adapter does not fit in your wall outlet, contact your electrician

  • After connecting the unit, check all cables in order to prevent damage or accidents, eg, due to tripping hazards
  • Make sure that the power cord is never crimped or damaged. Check the device and the power cord from time to time
  • Always disconnect power from the mains, when device is not used or before cleaning! Only handle the power cord by the plug Never pul out the plug by tugging the power cord
  • Unplug the power cord and power adapter from the power outlet f there is a isk of a lightning strike or before extended periods of disuse
  • Donot switch the unit on and off in short intervals
  • Do not connect the unit to a dimmerpack
  • Install the unit in a well ventilated place.
  • Never place any material over the lens
  • Always allow free air space of at least 58 cm around the unit for ventilation
  • Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture
  • For mounting height >180 cm, always fix the fixture with an appropriate safety-rope. Fix the safety-rope at the correct fixation points only. The safety-rope must never be fixed at the transport handles!
  • Never look directly at the light beam. Please note that fast changes in lighting, e.g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
  • This unitis not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.

CAUTION: If the power cord of the device is equipped with an earthing contact, then it must be connectedto an outlet with a protective ground Never deactivate the protective ground of a power cord

  • Make sure that the unit is not exposed to extreme heat, moisture or dust.
  • Clean the unit using a dry cloth
  • Donot touch the fixture bare-handed during its operation (housing becomes very hot). Allow the fixture to cool for at least 5 minutes before handlin  This unitis designed exclusively for indoor use, do not use this equipment in the immediate vicinity of fluid (does not apply to special outdoor equipment – in this case, observe the special instructions noted below). Do not expose this unit to flammable materials, luids or gases o Ifthe unit has been exposed to drastic temperature fluctuation (eg after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
  • Never attempt to bypass the thermostatic switch or fuses.
  • Do not dismantle or modify the unit
  • For replacement use fuses/bulb of same type and rating only.
  • Repairs, servicing and electric connection must be carried out by a qualified technician The ambient temperature must always be between -5° C and +45° C
  • IF this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void
  • Plastic bags must be kept out of reach of children
  • Unit must be installed out of the reach of children Never leave the unit running unattended

**** This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be handed
over tothe applcable collection paint for the recyclng of electrical and electronic equipment By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service or the shop where you purchased the product

UNPACKING INSTRUCTION

CAUTION! Immediately upon receiving the product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandiing. Save the package and all packing materials.In the event that the product must be returned to the factory, itis important that the product be returned in the original factory box and packing
IF the device has been exposed to drastic temperature fluctuation (e g, after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature

POWER SUPPLY
On the label on the backside of the product isindicated on this type of power supply must be connected. Check that the mains voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The product must also be directly connected to the mains and may be used No dimmer or adjustable power supply.
**** Always connect the device to a protected circuit (circuit breaker or fuse). Make sure the device has an appropriate electrical ground to avoid the risk of electrocution o fire

RIGGING

The fixture may be set up on a stable and even surface. By means of the fixing Facilties of the baseplate, the unit can also be mounted upside down to a truss, see below picture. For fixing, certified clamps with correct save working load are required. According to  the figure, the quick lock bolts of the omega brackets are placed into the openings provided in the base plate and turned clockwise until they lock (to the stop). The mounting place must be of sufficient stability and be able to support a weight of 10 times of the nit’s weight Secure the fixture with a safety cable so that it cannot fall down When carrying out any installation, always comply European and national guidelines concerning rigging, truss and all other safety issues. Always let the installation checked out by an authorized dealer BeamZ Pro BTF-100Z Fresnel
Zoom Toneelspot 100W LED Warm - clamps

DMX512 CONTROL

IF you are using a standard DMX contraller, you can connect the DMX output of the controller directly to the DMX input of the first fixture in a DMX chain Always connect the output of one unit with the input of the next fixture untilal fixtures are connected.BeamZ Pro BTF-100Z Fresnel Zoom Toneelspot
100W LED Warm - Control Caution: At the last fixture, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor between signal (-) and signal (+) and connect it to the DMX output of the last fixture in the line.![BeamZ Pro BTF-100Z Fresnel Zoom Toneelspot 100W LED Warm

CLEANING

The buildup of dust, dirt and other airborne particles will reduce the fixture’s light output. It will also prevent the fixture from cooling correctly, and this will reduce the fixture’s ifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow from ventilation systems, etc. The fixture’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere willincrease the tendency for dirt to clog
To get the best performance and ifetime from the fixture, inspect it regularly and clean it s soon as you see signs of dirt buildup Assess the operating environment each time you begin to use the fixture. In dusty or smoky conditions, inspect the Fixture after a few hours and check it frequently the fixture may attract dirt faster than you expect Draw upa cleaning schedule that will make sure that dirtis removed before it can build up.
Use the following guidelines

  • Disconnect the fixture from power and allow it to cool completely before cleaning
  • Do not use solvents, abrasives or any other aggressive product to clean the fixture.
  • Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it
  • Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces
  • Dry the fixture with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.

REPLACING THE FUSE

IF the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.

Procedure
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver
Step 2: Remove the old fuse from the fuse holder
Step 3: Install the new fuse in the fuse holder
Step 4 Replace the fuse holder in the housing

TROUBLE SHOOTING

The checkit below may help you troubleshoot in the unlikely event that a problem occurs while using the product

Symptom Possible cause Suggested action
No response from fixture No power to fixture.
Fuse blown or internal fault. Check that power is turned on

Check cables and connections
Replace mean fuse or contact Beamz support or Beamz authorized service partner. Do not
remove base or yoke covers. Do not attempt to replace a fuse or carry out any repairs or service that are not described in this User Manual Unless you have both authorization from Beamz support or Beamz authorized service partner.
Fixture resets correctly but does not respond (or does not respond correctly) to the controller| The controller is not connected, Bad DMX-line.
DMX-ine has no endresistance. Incorrect fixture addressing
Afixtureis defective and is disturbing data
transmission on the DMX-line.
Pin2 and 3 are reversed in XLR connection| Connect controller
Inspect connections and cables. Correct poor connections. Repair or replace damaged cables
Insert DMX terminator plug in DMX output socket of last fixture on DMX-line.
Check fixture address and DMX mode settings.
Unplug DMX IN and OUT connectors and connect them directly together to bypass one fixture at a time until normal operationis regained. Have defective fixture serviced by an authorized technicianInspect connections and cables. Install a phase-
reversing cable between the fixtures or swap pin 2 and 3in the fixture, that behaves erratically.
Error after fixture reset.| Effect requires mechanical adjustment| Check fixture’s software version and error messages for more information. Contact Beamz
support or Beamz authorized service partner
Light output cuts out intermittently.| Fixture too hot.
LEDs damaged
The power supply settings do not match local AC voltage and frequency.| ‘Allow fixture to cool Reduce ambient temperature. Ensure free airflow around fixture. Clean fixture if necessary
Disconnect fixture and contact Beamz support or Beamz authorized service partner.
Disconnect fixture. Check settings and correct if necessary

CONTROL MENU

Menu Description
DMX Addr d001-d512
2CH Channel mode

3CH
4CH
5CH
| S01-s.20| Stobe with speed increasing
| u.000 – u.255| Dimmer
| F.000 – 255| Zoom function
| nod.0| Dimmer speed
nod.1
nod.2
nod.3
nod.4
| Id01 – Id66| ID address setting
| -25 -100| Fixture temperature
| | Firmware version
| Yes| Reset
No
| 12-24.0| PWM refresh rate adjustment (KHz)

DMX CHANNELS
2 Channels

Channel Function Valve Description
1 Dimmer 000-255 Intensity 0-100%
2 Zoom 000-255  Motorised zoom, from 25° to 65°

3 Channels

Channel Function Valve Description
1 Dimmer 000-255 Intensity 0-100%
2 Strobe 000-255  Strobe speed, slow to fast
3 Zoom 000-255  Motorised zoom, from 25° to 65°

4 Channels

Channel Function Valve Description
1 Dimmer 000-255 Intensity 0-100%
2 Strobe 000-255  Strobe speed, slow to fast
3 Zoom 000-255  Motorised zoom, from 25° to 65°
4 Dimmer mode 000-005  Nofunction
006-055  Dimmer mode 0, no delay
056-105 Dimmer mode 1
106-155 Dimmer mode 2
156-205 Dimmer mode 3
206-255  Dimmer mode 4

5 Channels

Channel Function Valve Description
1 Dimmer 000-255 Intensity 0-100%
2 Strobe 000-255  Strobe speed, slow to fast
3 Zoom 000-255  Motorised zoom, from 25° to 65°
4 Dimmer mode 000-005 No function
006-055  Dimmer mode 0, no delay
056-105 Dimmer mode
106-155 Dimmer mode 2
156-205 Dimmer mode 3
206-255  Dimmer mode 4
5 ID address 000-003  AIlIDIDItoID
010-019 1Dt
020-629 D2
030-633 D3
…………………………………….. See table later in this manual

Detailed ID Addressing by DMX channel 5 in mode “5 Channels”.

Value Description
000-009 AIl ID1-ID66
010-019 ID1
020-029 ID2
030-039 ID3
040-049 ID4
050-059 ID5
060-069 ID6
070-079 ID7
080-089 ID8
090-099 ID9
100-109 ID10
110-119 ID11
120-129 ID12
130-139 ID13
140-149 1014
150-159 ID15
160-169 ID16
170-179 ID17
180-189 ID18
190-199 ID9
200-209 ID20
210 ID21
211 ID22
212 ID23
213 ID24
214 ID25
215 ID26
216 ID27
217 ID28
218 ID29
219 ID30
220 ID1
221 ID32
222 ID33
223 ID34
224 1035
225 ID36
226 ID37
227 ID38
228 ID39
229 ID40
230 ID41
231 ID42
232 ID43
233 ID44
232 ID43
233 ID44
234 ID45
235 ID46
236 ID47
237 ID48
238 ID49
239 ID50
240 ID51
241 ID52
242 ID53
243 ID54
244 ID55
245 ID56
246 ID57
247 ID58
248 ID59
249 ID60
250 ID61
251 ID62
252 ID63
253 ID64
254 ID65
255 ID66
253 ID64
254 ID65
255 ID66

TECHNICAL SPECIFICATIONS

Rated voltage 100-240VAC, 50-60Hz,12.-0.6A
LED 100Watt
Colour temperature 3200K
Beam angle 25°-85°
llluminance 34.300Ix
Flash rate 1-19Hz
DMX channels 2,3,4and 5via 3-pin XLR
Dimensions per unit 331x 210 x 245mm
Weight (per unit) 71kg

BeamZ Pro BTF-100Z Fresnel Zoom Toneelspot 100W LED Warm -
changeDesign and product specifications are subject to change without prior notice.
European Union
Tronios BV,
Bedrijvenpark Twente Noord 18,
7602KR Almelo, The Netherlands
2014/35/EU
2014/30/EU
2011/65/EC ****

United Kingdom
Tronios Ltd.,
130 Harley Street,
London W1G 7JU, United Kingdom
S1.2016101
5120161091
5120123032 offers a wide range of high performance lighting equipment and related accessories for the rental, entertainment and architectural lighting markets. BeamZ Pro stands for performance, innovation and value pricing!

BEAMZLIGHTING.COM

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals