SUNSUN CEF-16000 High-Performance Pond Pump User Manual

June 5, 2024
SUNSUN

SUNSUN CEF-16000 High-Performance Pond Pump LOGO

SUNSUN CEF-16000 High-Performance Pond Pump

SUNSUN CEF-16000 High-Performance Pond Pump product

Please read and follow the operating instructions and safety information prior to initial operation.
Technical changes reserved!
Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further developments.
The information contained in this document may alter at any time without prior notice. No part of this document may be copied or otherwise duplicated without prior written consent. All rights reserved. WilTec Wildanger Technik GmbH cannot be held liable for any possible mistakes in this operating manual, nor in the diagrams and illustrations shown.
Although WilTec Wildanger Technik GmbH has made every possible effort to ensure that this operating manual is complete, accurate, and up-to-date, errors cannot be ruled out entirely.
If you have found an error or wish to suggest an improvement, we look forward to hearing from you.
Send us an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in several languages can be found in our online shop:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler Germany
Do you wish to collect your goods? Our address for collection is:
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler Germany
In order to shorten the waiting time and to allow for an easy on-site processing, we kindly ask you to contact us briefly beforehand or to place your order via the webs hop.
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
To return your goods for exchange, repair, or other purposes, please use the following address. Atten-tion! To allow for a trouble-free complaint or return, it is important to contact our customer service team before returning your goods.
Retourenabteilung
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler Germany
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

Introduction

Thank you for choosing to purchase this quality product. To minimize the risk of injury, we ask you to always take some basic safety precautions when using this product. Please read this operating manual carefully and make sure that you understand it.
Keep these operation instructions in a safe place.
CAUTION:

  • In and near standing water, garden ponds, and swimming ponds, the use of this device is only allowed with a fault current protection switch with a triggering nominal current up to 30 mA (according to VDE 0100 Article 702 and 738).
  • The device is not suitable for use in swimming pools, paddling pools of any kind, or bodies of water in which people or animals may stay during operation. Operation of the device with people being in the danger area is not permitted. Ask an electrician, if necessary.
  • The device is not intended for use by persons (including children) with impaired or limited physical, sensory, and mental abilities or lack of experience and/or real knowledge, unless they are supervised by a person responsible for their safety or follow the instructions made by this person on how to correctly use the device.
  • Children should be supervised to ensure that they do not play with the device.

ATTENTION :

  • Perform a visual inspection of the device before every use. Do not use the device if the safety appliances are damaged or worn out. Never override safety regulations.
  • Only use the device accordingly to the intended purpose stated in this manual.
  • You are responsible for the safety of the working zone.
  • If the cable or the plug is damaged due to external influences, the cable must not be repaired. It must be replaced with a new one. This work may only be carried out by a qualified electrician.
  • The voltage of 230 V AC indicated on the type plate of the device must match the existent mains voltage.
  • Never lift, carry, or fix the device by using the power cable.
  • Make sure that the electric plug connections are protected from flood and humidity.
  • Always unplug the appliance before working on it.
  • The user is responsible for complying with local safety and mounting regulations. Ask an elec-trician, if necessary.
  • The user must take appropriate measures (e.g., installation of an alarm system, a reserve pump, etc.) to prevent damage caused by the flooding in case of device malfunctioning.
  • In case of device failure, repairs can only be carried out by an electrician.
  • The device must never run dry or be operated with its suction line fully closed.
  • Do not use this device to operate swimming pools.
  • This device must not be integrated into any kind of domestic water circuit meant for potable water.

WARNING :
Read all safety precautions and instructions. Failure to obey the safety precautions and instructions might cause an electric shock, a fire, and/or severe injuries. Keep all safety precautions and instructions for future use.

Resistance
  • The maximum temperature of the pumped liquid should not exceed +35 ℃ in continuous operation.
  • The transport of aggressive fluids (acids, bases, etc.) as well as of abrasive substances (e.g., sand) must be avoided.
Electrical connection
  • The electrical connection is made to an earthed socket 230 V ~ 50 Hz. Fuse min. 6 A.
  • The motor is protected from overcharge and blockage with the help of the built-in thermal motor protection. When overheated, the pump motor is automatically switched off by the thermal pro-tection; after cooling down, the pump automatically restarts.
Mains connection

The pond pump that you have purchased is already equipped with a protection plug. The pump is meant to be connected to a 220/230 V~50 Hz safety socket. Make sure that the socket is sufficiently protected (min. 6 A) and fully functional. Plug in the plug, the pump is operational.

Commissioning
  1. Do not fail to familiarise yourself with the safety regulations before commissioning.
  2. The existing mains’ voltage (V) and frequency (Hz) must match the indications of the nameplate of the device.
  3. Make sure to connect all hoses properly. This is the only way the water can flow properly.
  4. Place the pump horizontally onto a solid surface, at least 20 cm beneath the water surface. Respect the max. immersion depth: 1.5 m.
  5. Do not place the pump directly into the mud of the bottom of the pond; place it on a raised surface.
  6. Place the cable in a secure manner so that it cannot be damaged.
  7. Connect the pump to the power supply.

Important instructions:

  • Never operate the pump without a filter basket; a filter basket protects the pump against any coarse dirt that would obstruct the pump.
  • The pump must not run dry; the pump shaft would otherwise be damaged.
  • The pump must regularly be cleaned, especially with the water pumped containing a lot of dirt or suspended particles; otherwise, it will not be able to work properly.

Maintenance/cleaning

  • When maintaining and cleaning the pump, the safety instructions must always be followed.
  • Use a soft brush and flowing water to clean the filter housing monthly or in case the pumping power diminishes.
  • The frequency of use of the pump must be irrelevant for the cleaning. Even used seldom, the pump must be cleaned regularly.
Cleaning
  1. Disconnect the pump from the power supply.
  2. Disassemble the pump housing and keep in mind the order of the individual components.
  3. Clean the pump with a soft brush and under running water.
  4. Remove dirt and rotten particles.
  5. Reassemble the pump in the reversed order.
Storage during winter
  1. Disconnect the pump from the power supply and take it out of the water.
  2. Clean the pump thoroughly according to the cleaning instructions.
  3. Check the device for possible damage.
  4. Store the pump under frost-free condition and, if possible, in a container with water.

Caution : Never immerse the power plug into the water.

Technical specifications

Item number

|

50954

|

50955

|

50956

|

50957

---|---|---|---|---

Model

|

CEF-16000

| CEF-22000| CEF-26000|

CEF-30000

Power supply

|

230–250 V (alternating current) / 50 Hz

Power consumption (W)|

75

| 95| 135|

200

Max. flow rate (ℓ⁄h)|

16,000

| 22,000| 26,000|

30,000

Max. lifting height (m)|

2

| 2.6| 3.5|

4

Hose connection (㎜)|

75

| 75| 110|

110

Length of cable (m)|

10

| 10| 10|

10

Exploded view and parts list

SUNSUN CEF-16000 High-Performance Pond Pump 01

Name
1 Elbow pipe
2 Straight pipe
3 Pump housing
4 Self-tapping screw
5 M6×60 screw
6 Motor
7 Rotor
8 Gasket
9 Impeller casing
10 Filter casing
11 M6×16 screw

Regulations for waste disposal

  • The Waste Electrical and Electronic Equipment Directive (WEEE Directive, 2012/19/EU) of the EU was implemented in the German law related to electrical and electronic equipment and appliances.
  • All WilTec electric devices that fall under the WEEE directive are labelled with the symbol of a crossed-out wheeled rubbish bin. This symbol indicates that this electric device must not be disposed of with the domestic waste.
  • WilTec Technik GmbH is registered with the German registration authority EAR (Stiftung ElektroAltgeräte Register) under the WEEE-registration number DE45283704.
  • Disposal of used electrical and electronic devices (in-tended for use in the countries of the European Union and other European countries with a separate waste collection system for these devices).
  • The symbol on the packaging or the product itself indicates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste. By disposing of this product correctly, you contribute to the protection of the environment and the health of your fellow people. Inappropriate disposal threatens the environment and health.
  • Material recycling helps to reduce the consumption of raw materials.
  • Additional information about the recycling of this product can be provided by your local commune, the municipal waste disposal facilities, or the store where you purchased the product.

Important Note:
Reproduction and any commercial use (of parts) of this operating manual, requires a written permission of WilTec Wildanger Technik GmbH.

© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals