Installation
IMPORTANT:
To the installer: Installation of these units should be carried out by a
competent person and the appropriate codes of practice adhered to, thus
ensuring safe installation. Pass to the user: Do not discard this document. It
contains important guidelines on Operation, Loading, Cleaning and Maintenance
and should be kept for reference.
DISPOSAL REQUIREMENTS
If not disposed of properly all refrigerators have components that can be
harmful to the environment. All old refrigerators must be disposed of by
appropriately registered and licensed waste contractors, and in accordance
with National laws and regulations.
Positioning/unpacking
Important: Ensure a minimum clearance of 25mm above and beside the cabinet for ventilation and efficient operation. Where possible, ensure the cabinet is not adjacent to a heat source.
Remove the shrinkwrapping, cardboard corner protectors, cardboard lid and packaging from the door opening surround making sure that any sharp instrument used does not cause damage, plus remove any Quality labels. Documentation is inserted into a clear pocket located inside the cabinet. To remove from pallet, cut the cable ties situated through the base plate slot that hold the cabinet to the pallet.
Feet
Models are supplied with adjustable levelling feet already fitted.
Shelf Supports
The HR140, LR140 / HR150 / HR200, LR200 / HR360, LR360 / HR 410, are supplied
with slotted removable shelf supports allowing flexible shelf partitions.
The rear supports have an inbuilt ‘slot’ to prevent the shelf from damaging
the rear air duct.
The LR150 / LR 410 is supplied with fixed freezer shelves.
Shelf supports for models
HRB120, LRB120 / HR120, LR120 / HR240, LR240
Defrosting
The HR150 / HR 410 is fitted with an automatic defrost function ensuring the
cooling plate remains free from ice. The condensate water is automatically
dispersed using the heat from the refrigeration unit.
The LR150 / LR 410, being static freezer shelves, requires manual defrosting.
All the stored product should be removed and placed in a separate freezer
storage cabinet. Switch off at the mains electric supply. Leave the door open
and place bowls inside to catch the water as the freezer shelves defrost.Once
fully defrosted dry the inside of the cabinet and switch on again. Do not
replace the frozen food until the cabinet has reached its normal operating
temperature.
WARNING: Do not use any sharp instruments or heat to remove the ice from the freezer shelf as this may cause damage.
start up & operation
Switching On
If the cabinet has been laid on its back at any time DO NOT switch on immediately but leave in the upright position for at least 60 minutes.
user operation guidelines
Initial Start Up
Insert the fused mains plug into the wall socket and switch on at the mains. The cabinet will start automatically and display the actual internal temperature, as the operating temperature has been pre-set. Allow the cabinet to reach its normal operating temperature before loading.
To Change Temperature Setting
It will not normally be neccessary to change the setting however should this be neccessary:
-
Check storage temperature setting Press button 1 and hold
Display Shows: Temperature Setting -
Increase storage temperature Press button 1 and hold
Display Shows: Temperature Setting (flashing) Press button 2 to increase Temperature Setting Release both buttons. -
Lower storage temperature Press button 1 and hold
Display Shows: Temperature Setting
Press button 3 to decrease Temperature Setting Release both buttons.
Door Lock
To lock the door, insert the key and turn straight through 90˚.
Internal Light (Where fitted)
The ON/OFF switch is located on the front of the light fitting.
loading
Airflow
When loaded, ensure that air can circulate around / through stored products.
Load Distribution
Evenly distribute the load (max 25kg per shelf or maximum load 50kg whichever is the highest).
Food
Cover all foods and separate raw and cooked foods.
cleaning/maintenance
N.B. Before internal cleaning, un-plug the cabinet from the mains supply.
Cleaning Instructions
IMPORTANT:
Cared for correctly the cabinet will retain its appearance for many years.
White Exterior: wipe with a warm damp soapy cloth followed by a clean damp
cloth and thoroughly dry. Stainless Steel Exterior: use a proprietary
stainless steel cleaner following the manufacturers instructions.
Aluminium Interior: to be washed with soapy water, rinsed and dried
thoroughly.
WARNING:
High alkaline cleaning agent or those containing bleaches, acids and chlorines
are very harmful to stainless steel. Corrosion and pitting may result from
their accidental or deliberate application. If any of these liquids should
come into contact with the cabinet during general kitchen cleaning, wipe down
the affected area immediately with clean water and rub dry. Never use wire
wool or scouring powders on any surface. After cleaning allow the cabinet to
reach its normal operating temperature before reloading with product. During
usage all spills should be wiped clean immediately but care should be taken
not to touch the interior of the freezer cabinet as warm skin can ‘freeze’ to
metal.
CONDENSER:
Clean the condenser, located in the unit compartment, when it becomes dirty.
Important: Disconnect the mains electrical supply to the machine prior to
cleaning the condenser.
Clean the condenser using a soft brush or vacuum cleaner. NOTE: if there are
any stubborn grease deposits etc left on or through the condenser call your
Foster Authorised Service Company to carry out a full service.
Once the condenser has been cleaned switch the unit on.
Failure to carry out this action may invalidate the warranty of the condensing
unit. Any service calls due to lack of maintenance may be chargeable.
Door Gaskets
These should be inspected on a regular basis and replaced if damaged. To
clean, wipe with a warm damp soapy cloth followed by a clean damp cloth
and finally thoroughly dry before closing the door.
Shelf Supports & Shelves – All Models
Remove the shelves and shelf support (by removing fixing screw). The shelves
are dishwasher safe, however wash the vertical supports with
warm soapy water, rinse and thoroughly dry before replacing.
Operational failure
Problem Diagnosis
Checks must be carried out by a competent person.
Before calling a Foster Authorised Service Company check the following:
a) Power failure (may be off at source)
b) Damaged mains lead plug.
When requesting service assistance always quote the following:
a) cabinet serial number (E……….)
b) cabinet model number
Both taken from the serial plate located inside the cabinet.