PRODUCT

PARALLEL BARS WITH PLATFORM: 260208
It is imperative to follow the instructions below to assure correct assembly, installation as well as correct use of the parallel bars 260208. Obligation to anchor to the floor, according to din en 12182.SPORT TEC-23510-Parallel-
Bars-Exclusive-Beam-Length-User-Manual-FIG-1

Read the instructions and use the product as directed according to its function.

TOOLS REQUIRED

SPORT TEC-23510-Parallel-Bars-Exclusive-Beam-Length-User-
Manual-FIG-3

OVERVIEW

SPORT TEC-23510-Parallel-Bars-Exclusive-Beam-Length-User-
Manual-FIG-4

Included in the box

SPORT TEC-23510-Parallel-Bars-Exclusive-Beam-Length-User-Manual-
FIG-5

INSERT THE WHITE CYLINDRICAL SUPPORT TUBE INTO THE DESIGNATED FITTING ON THE BASE

SPORT TEC-23510-Parallel-Bars-Exclus

NOTE

****TO ENSURE CORRECT ASSEMBLY OF THE ITEM IT IS NECESSARY TO START AT THE BOTTOM HOLE AND PROCEED FROM THERE UPWARDS

  • NSERT THE SCREW WITH ITS CONCAVE WASHER INTO THE BOTTOM HOLE (A)
  •  FASTEN THE NUT WELL SO THAT THE CONCAVE WASHER SITS TIGHTLY ON THE SURFACE OF THE TUBE
  • UNSCREW THE NUT AGAIN
  • FIT ANOTHER CONCAVE WASHER TO THE OPPOSITE SIDE
  • PUT THE NUT ON THE SCREW AGAIN AND TIGHTEN AS FAR AS IT WILL GO
  • REPEAT THE PROCEDURE FOR THE UPPER SCREWS
  • TO FINISH, FIT THE WHITE COVERINGS INCLUDED IN DELIVERY
  • PROCEED AS DESCRIBED ABOVE TO ANCHOR ALL OTHER WHITE SUPPORT TUBES
  • FIT ONE BOLT LEVER TO THE SIDE OF EACH SUPPORT TUBE
  • OPEN / CLOSED POSITIONS OF THE BOLT LEVER
  • CORRECT POSITION OF THE BOLT LEVER TO LOCK THE SKID PIPE IN PLACE
  • REMOVE THE PACKAGING MATERIAL FROM THE HANDRAILS
  • FIX BOTH HANDRAILS IN THE INTENDED POSITION USING THE NUTS INCLUDED IN DELIVERY

ASSEMBLY OF PARALLEL BARS

  • THE ASSEMBLED PARTS (B) PROVIDE FOR THE FIXATION OF THE HANDRAIL TO ITS SUPPORTING STAND.
  • SCREW-NUT (B1) HAS TO BE TIGHTENED WITHOUT IMPEDING THE ROTATION OF THE HANDRAIL, TO ALLOW FOR ITS ADJUSTMENT IN BREADTH.
  • FOR ADJUSTMENT IN BREADTH, RELEASE LEVER (C) AND GENTLY PUSH AND TURN (TO THE LEFT/RIGHT) CHROMED SUPPORT (D).

INSTALLATION BARRES PARALLELES

THE HEIGHT OF THE PARALLEL BARS IS CORRECTLY AND SECURELY ADJUSTED, ONCE THE FASTENER TIGHTLY SITS IN ONE OF THE SPECIFICALLY DESIGNED NOTCHES. THE NOTCH POSITIONING FOR HEIGHT ADJUSTMENT IS: WRONG. REFER TO FIGURE 3 FOR CORRECT ALIGNMENT.

THE NOTCH POSITIONING FOR HEIGHT ADJUSTMENT IS: CORRECT. IN THIS ALIGNMENT THE FASTENER (A) IS CORRECTLY POSITIONED TO SNAP IN THE DESIGNATED NOTCH.

  • TO FINISH THE INSTALLATION OF THE PARALLEL BARS, ASSEMBLE THE OPPOSITE HANDRAIL BY REPEATING THE ABOVE PROCEDURE
  • VIEW OF THE PARALLEL BARS WITH THE HANDRAILS CORRECTLY INSTALLED

IDENTIFICATION LABEL

SPORT TEC-23510-Parallel-Bars-Exclusive-Beam-Length-User-Manual-
FIG-26

WARNINGS

CLASSIFICATION AND USE OF PARALLEL BARS WITH PLATFORM: 260208

Read the instructions and use the product as directed according to its function. Do not use the product in a way other than its intended purpose.

INTENDED USE
Parallel bars with base for continuous use in a manned hospital environment. Immobilized patients with simple fractures or residents in aged-care facilities, who require firm support, adjustable in height and width for a greater feeling of security.

TYPE OF PATIENT
Adults need to learn how to walk again or simply to move around safely inside a room and along a path.

PLACE OF USE
Hospitals, specialized clinics, aged-care facilities

OPERATORS QUALIFIED TO USE THE PRODUCT
All healthcare professionals, physiotherapists, and related industries. The instructions were given to the patient by the healthcare professional.

CONTRAINDICATIONS
Follow the safety instructions in the user manual. Not suitable for sports use.

OTHER INDICATIONS
The device does not have essential levels of performance. Report all serious incidents that occur due to the device. Report the incident to the manufacturer and the competent authority At the end of its life, the product must be disposed of in accordance with local regulations and taken to specific waste collection facilities.

DATA SHEET

PARALLEL BARS WITH PLATFORM: 260208

  • Dimensions: 250 X 36 ∆ 87 X 78 ∆ 104 cm
  • Weight: 57,5 kg
  • Storage: dry, dark place, -20°+60°
  • Cleaning: it is generally recommended to clean the device after each use and to carry out the disinfection cycle periodically. To clean the device, wipe its parts with a cloth moistened with warm water. Do not use any agents that could damage the surface of the device through abrasion or overly aggressive treatment.
  • Operating temperature: 0° / +40°
  • Expected lifetime: it is estimated that the device can be used for 10 years.
  • It is mandatory for the user and the patient to use disposable gloves and shoes with clean rubber soles with disposable overshoes

CARRYING CAPACITY OF THE DEVICE

  • Stabilimento e sede legale:via del Lavoro Z.I.
  • 31013 Codogné (TV) Italia
  • Tel. +39 0438 777099 – 778370 Fax +39 0438 777091