Remote Controller Specifications

Model RG10A1(D2S)/BGEF
Rated Voltage 3.0V( Dry batteries R03/LRO3x2)
Signal Receiving Range 8m
Environment -5°C–60°C(23°F–140°F)

Quick Start Guideinventor ΝUVI 09WF Air Conditioning Systems Remote
Controller - fig

NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.

SPECIAL NOTE

  • Button designs on your unit may differ slightly from the example shown.
  • If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
  • When there are wide differences between “Remote controller Manual” and “USER’S MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.

Handling the Remote Controller

Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use.

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.
    inventor ΝUVI 09WF Air Conditioning Systems Remote Controller -
battery

BATTERY NOTES
For optimum product performance:

  • Do not mix old and new batteries or batteries of different types.
  • Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.

BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.

TIPS FOR USING REMOTE CONTROL

  • The remote control must be used within 8 meters of the unit.
  • The unit will beep when a remote signal is received.
  • Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
  • Remove batteries if the remote will not be used for more than 2 months.

NOTES FOR USING REMOTE CONTROL
The device could comply with the local national regulations.

  • In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
  • In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
  • Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.

Model: RG10A1(D2S)/BGEF

Remote Screen Indicators

Information are displayed when the remote controller is powered up.

Note: All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation, only the relative function signs are shown on the display window.

How to Use Basic Functions

ATTENTION
Before the operation, please ensure the unit is plugged in and power is available.
AUTO Mode![inventor ΝUVI 09WF Air Conditioning Systems Remote Controller

NOTE:

  1.  In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature.
  2. In AUTO mode, fan speed can not be set.

COOL or HEAT Modeinventor ΝUVI 09WF Air Conditioning Systems Remote
Controller - temperature

DRY Modeinventor ΝUVI 09WF Air Conditioning Systems Remote Controller -
temperature 1

NOTE: In DRY mode, fan speed can not be set since it has already been automatically controlled.
FAN Modeinventor ΝUVI 09WF Air Conditioning Systems Remote Controller -
fig 3

NOTE: In FAN mode, you can’t set the temperature. As a result, no temperature is displayed in the remote screen.
Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.
TIMER ON settinginventor ΝUVI 09WF Air Conditioning Systems Remote
Controller - fig 4

TIMER OFF settinginventor ΝUVI 09WF Air Conditioning Systems Remote
Controller - fig 5

NOTE:

  1. When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1-hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
  2. Cancel either function by setting its timer to 0.0h.

TIMER ON & OFF setting (example)
Keep in mind that the time periods you set for both functions refer to hours after the current time.

How to Use Advanced Functions
Swing function
Press Swing button

The horizontal louver will swing up and down automatically when pressing Swing button. Press again to make it stop.
Airflow direction

Keep pressing this button for more than 2 seconds, the vertical louver swing function is activated. (Model dependent)
If continue to press the SWING button, five different airflow directions can be set. The louver can be moved at a certain range each time you press the button. Press the button until the direction you prefer is reached.
NOTE: When the unit is off, press and hold the MODE and SWING buttons together for one second, the louver will open for a certain angle, which makes it very convenient for cleaning. Press and hold the MODE and SWING buttons together for one second to reset the louver(Model dependent).
LED DISPLAY Press this button to turn on and turn off the display on the indoor unit.

| Press this button for more than 5 seconds(some units)
---|---

Keep pressing this button for more than 5 seconds, the indoor unit will display the actual room temperature. Press more than 5 seconds again will revert back to display the set temperature.
ECO/GEAR function

| Press this button to enter the energy-efficient mode in a sequence of following:
ECO GEAR(75%) GEAR(50%) Previous setting mode ECO……
Note: This function is only available under COOL mode.
---|---

ECO operation:
Under cooling mode, press this button, the remote controller will adjust the temperature automatically to 24 C/75 F, fan speed of Auto to save energy (only when the set temperature is less than 24 C/75 F). If the set temperature is above 24 C/75 F, press the ECO button, the fan speed will change to Auto, the set temperature will remain unchanged.
NOTE:
Pressing the ECO/GEAR button, or modifying the mode or adjusting the set temperature to less than 24 C/75 F will stop ECO operation.
Under ECO operation, the set temperature should be 24 C/75 F or above, it may result in insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.
GEAR operation:
Press the ECO/GEAR button to enter the GEAR operation as follows:  75%(up to 75% electrical energy consumption)

50%(up to 50% electrical energy consumption)

Previous setting mode.
Under GEAR operation, the display on the remote controller will alternate between electrical energy consumption and set temperature.
Silence function

| Keep pressing the Fan button for more than 2 seconds to activate/disable the Silence function.
Due to the low-frequency operation of the compressor, it may result in insufficient cooling and heating capacity. Pressing ON/OFF, Mode, Sleep, Turbo or Clean buttons while operating will cancel the silence function.
---|---

FP function
Press this button 2 times for one second under HEAT Mode and set the temperature of 16 C/60 F or 20 C/68 F.

| The unit will operate at high fan speed (while the compressor on) with the temperature automatically set to 8 C/46 F.
---|---

Pressing On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel this function.
LOCK function

| Press together the Clean button and Turbo button at the same time for more than 5 seconds to activate Lock function. All buttons will not respond except pressing these two buttons for two seconds again to disable locking.
---|---

SET function

  • inventor ΝUVI 09WF Air Conditioning Systems Remote Controller - fig 19 Press the SET button to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm.
  • To cancel the selected function, just perform the same procedures as above.
  • Press the SET button to scroll through operation functions as follows: Breeze Away ( ) Fresh ( ) Sleep( ) Follow Me( ) AP mode( )
    [ *]: If your remote controller has a Breeze Away button, Fresh button or Sleep button, you can not use the SET button to select the Breeze Away, Fresh or Sleep feature.

Sleep function ( ) :
The SLEEP function is used to decrease energy use while you sleep (and don t need the same temperature settings to stay comfortable). This function can only be activated via remote control. , For the detail, see sleep operation in,
USER S MANUAL.
Note: The SLEEP function is not available in FAN or DRY mode.
FRESH ( ): When the FRESH function is initiated, the UV-C lamp and the ion generator are energized and will help to purify the air in the room.
Breeze Away function ( ):
This feature avoids direct airflow blowing on the body and makes you feel like indulging in silky coolness.
NOTE: This feature is available under Cool, Fan, and Dry mode only.
Follow me function ( ):
The FOLLOW ME function enables the remote control to measure the temperature at its current location and send this signal to the air conditioner every 3 minutes interval.
When using AUTO, COOL or HEAT modes, measuring ambient temperature from the remote control(instead of from the indoor unit itself) will enable the air conditioner to optimize the temperature around you and ensure maximum comfort.
NOTE: Press and hold the Turbo button for seven seconds to start/stop the memory feature of Follow Me function. If the memory feature is activated, On displays for 3 seconds on the screen. “ ” If the memory feature is stopped, OF displays for 3 seconds on the screen.  While the memory feature is activated, press the ON/OFF button, shift the motor power failure will not cancel the Follow me function.  “ ”
AP function ( ) :
Choose AP mode to do wireless network configuration. For some units, it doesn’t work by pressing the SET button. To enter the AP mode, continuously press the button seven times in 10 seconds.
All the pictures in the manual are for explanatory purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same. The company may not be held responsible for any misprinted information. The design and the specifications of the product for reasons, such as product improvement, are subject tochange without any prior notice.
Please consult with the manufacturer at +30 211 300 3300 or with the Sales agency for further details. Any future updates to the manual will be uploaded to the service website, and it is advised to always check for the latest version.

inventor ΝUVI 09WF Air Conditioning Systems Remote Controller -
QRhttps://www.inventorairconditioner.com/media-library
Scan here to download the latest version of this manual.
www.inventorairconditioner.com/media- library

inventor ΝUVI 09WF Air Conditioning Systems Remote Controller - icon
6NOTES…………..
AIR CONDITIONING SYSTEMS REMOTE CONTROLLER


V:1.1.022022

Manufacturer: INVENTOR A.G. S.A.
24th km National Road Athens – Lamia & 2 Thoukididou Str.,
Ag.Stefanos, 14565
Tel.: +30 211 300 3300, Fax: +30 211 300 3333 –www.inventor.ac

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

inventor User Manuals

Related Manuals