LUTRON HKS-0-FM Starter Vive Wireless Hub Flush Mount Instruction Manual

June 5, 2024
Lutron

LUTRON-logo

LUTRON HKS-0-FM Starter Vive Wireless Hub Flush Mount

LUTRON-HKS-0-FM-
Starter-Vive-Wireless-Hub-Flush-Mount-product

Included Components

LUTRON-HKS-0-FM-Starter-Vive-Wireless-Hub-Flush-
Mount-fig-16

Important Notes

General

  1.  For installation by a qualified electrician in accordance with all local electrical codes.
  2.  Install the Vive hub where the button and terminal block/wires are not accessible to users in the space.
  3.  The primary branch circuit must be protected by a 10 A or 16 A breaker (as applicable).
  4.  The primary wiring must be 1.0 mm2 to 2.5 mm2 (18 AWG to 14 AWG) and rated for at least 75 ˚C.
  5.  If moisture or condensation is evident, allow the product to dry completely before installation.
  6.  Operate between 0 °C and 40 °C.
  7.  0% to 90% humidity, non-condensing.
  8.  For indoor use only.

Vive Hub

  1.  Lutron recommends that the Vive hub not be installed above ceiling tiles with a metal backing.
  2.  Clean the Vive hub with a soft damp cloth only. DO NOT use any chemical cleaners.
  3.  DO NOT paint the Vive hub.
  4.  The Vive hub is part of a system and cannot be used to control a load without a compatible system device. Please refer to the system device(s) instruction sheet or www.lutron.com for installation information.
  5.  HKS-1, HKS-2 support up to 700 Lutron Wireless devices. HKS-0 supports 75 Lutron Wireless devices. Devices must be located within 22 m of the Vive hub.
  6. Vive hub units should be mounted in the middle of a non-metal ceiling tile or drywall, visible from the inside of the space.
  7. Metal ceilings must have a ≥3 mm gap of non-metal material which extends the entire length of the tile on at least one edge. This is often achieved by foam spacers that are used to prevent tile-to tile rattling.
  8.  Metal ceilings which are continuous (with no gap) or those that are interlocked, must have a total surface area that is less than 81 m2 for each section. The overall space can be larger as long as there are non-metal sections bordering or intersecting the metal sections.
  9.  All wireless devices must be within 22 m of the Vive hub. This range applies to both Clear Connect devices and Wi-Fi.
  10.  A corporate Wi-Fi network can interfere with the Wi-Fi on the Vive hub. Where a corporate Wi-Fi network exists, it is recommended to connect the Vive hub to the corporate network using the Ethernet connection on the hub and disable the hub’s Wi-Fi.
  11.  Must be mounted a minimum of 3 m away from Wi-Fi router.

Typical Application

Product Overview

LUTRON-HKS-0-FM-Starter-Vive-Wireless-Hub-Flush-Mount-
fig-2

Installation

  • Turn OFF power at circuit breaker.
    WARNING! Shock Hazard. May result in serious injury or death. Turn off power at circuit breaker before installing the unit.

  • Installing the Mounting Adapter
    The Vive hub can be mounted on a variety of ceiling materials (thickness ranging from 6 mm to 32 mm) with the mounting bracket provided.

Flush-mount adapter

  1.  Cut a 153 mm diameter mounting hole in the ceiling to insert the mounting bracket. Please refer to the Vive Hub Flush-Mount Bracket Template.
  2.  Insert the flush-mount Adapter into the hole and rotate the three brackets outwards by turning screws.
  3.  Using a Phillips head screwdriver, hand-tighten the brackets, clamping the adapter to the ceiling. DO NOT overtighten.

Surface-mount adapter

  1.  Remove installed doors to access the optional conduit knockouts. The knockouts provide a connection point for conduits.
    Attach the surface-mount adapter to the wall or ceiling using the included screws or appropriate screws that will securely mount the device.

  2.  Alternate installation methods: Attach the surface-mount adapter to a Lutron-supplied US-style 101.6 mm x 101.6 mm junction box

Wiring

Power Supply

  1.  Ground the junction box in accordance with local codes.
  2.  Mount the power supply to a Lutron-supplied US-style 101.6 mm x 101.6 mm junction box The power supply must be mounted within 30 m of the Vive hub.
  3.  Make wiring connections as shown.
    Note: Maintain separation of the power supply PELV output wiring from all other conductors by a minimum of 6.4 mm or by a non-conductive sleeve or non- conductive barrier. LUTRON-HKS-0-FM-Starter-Vive-Wireless-Hub-Flush-Mount-
fig-10

Vive Hub

  1.  Run the low-voltage wiring from the power supply to the Vive hub. Most applications will require an additional length of wire to connect the junction box with the Vive hub. Wiring should be 0.2 mm2 to 2.5 mm2 (24 AWG to 12 AWG).

  2.  Wire the Vive hub terminal block. Contact Closure Input 1 (CCI1) is programmed by default to activate load shed. Closing this input will shed the lighting load by 20% for connected Vive compatible lighting devices.
    Note: Terminal blocks are removable for ease of wiring.
    Note: Contact Closure Input 2 (CCI2) is for future release functionality. LUTRON-HKS-0-FM-Starter-Vive-Wireless-Hub-Flush-Mount-
fig-11

  3. Connect the Ethernet cable to connect to Building Management Systems, wired networks, and other Vive hubs.

Attaching the Vive Hub to the Adapter

Note: Prior to installing the hub, record the Wi-Fi SSID printed on the label. Attach the Vive hub into the ceiling-mount adapter by inserting and twisting in a clockwise direction until the hub locks into place.

Flush-mount adapter
Twist Vive hub until ratcheted flush with ceiling.

Surface-mount adapter
Twist Vive hub until hub clicks into place.

Programming

The Vive hub can be set up easily with any Wi-Fi-enabled iOS or Android- compatible device.

  1.  Download the Lutron Vive app.
  2.  Open the app and follow the instructions.

LED Feedback

LUTRON-HKS-0-FM-Starter-Vive-Wireless-Hub-Flush-Mount-
fig-14

Troubleshooting

LUTRON-HKS-0-FM-Starter-Vive-Wireless-Hub-Flush-Mount-
fig-15

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals