Whale GP0650 V-Pump Mk 6 Hand-Operated Galley Water Pump Instruction Manual

June 3, 2024
Whale

GP0650 V-Pump Mk 6
Hand-Operated Galley Water Pump
Instruction Manual

GP0650 V-Pump Mk 6 Hand-Operated Galley Water Pump

Read carefully before installation and use.
To the fitter: Check that the product is suitable for the intended application, follow installation instructions, and ensure operating instructions are passed onto the end user.
To the User: Read the following instructions carefully.

Application

This product is designed for use as a domestic freshwater & saltwater hand pump in caravans and boats. Use for any other purpose or with any other liquid, is not recommended and is entirely at the user`s risk.
This pump may also be used in conjunction with an in-line pump, or as a backup to a submersible pump.Whale GP0650 V-Pump Mk 6 Hand-Operated Galley Water
Pump

Installation

Choose an installation where the pump can be operated comfortably. Note: The maximum reach of the outlet spout is 115mm (4½”) Once you have found your location, drill a 25mm (1″) hole, fit the pump, position the base, and secure using the two wood screws.
Hose connection
If using Whale Water System 15 pipework WX1504 equal straight will fit directly onto the pump, if using System12 use WX1504 & WS1215 stem reducer 15mm12mm alternatively you can use 13mm (½”) flexible tubing.
The height of the pump may be adjusted by loosening the screw (A).

Operation

To operate the pump the handle is up and down, water will be discharged on both strokes.

Maintenance

Regular inspection of valves and seals is recommended with cleaning and replacement of components as necessary.
To dismantle the pump:
Unscrew the head and spout from Barrel, and pull the plunger and head from the barrel. Unscrew the plunger cup seat from the plunger rod and pull the head and spout from
plunger rod. To remove the packing seal from the head, carefully ease cap (B) off using a flat screwdriver, and replace the packing seal making sure to fit the new seal the same way round as the old seal (U facing down).
Note : Replacing O-Ring (C) may prove difficult to remove and we recommend that it is not replaced unless a leak is observed under the head.
Replace the cup washer, O-Ring (D), and buffer on the plunger cup seat.
Reassemble making sure that the cap is securely pushed back into position To replace the bottom valve (E) unscrew the base from the barrel of the pump. A service kit AK0618 is available from dealers.
Contact Whale for MK5 Vpump drawing or instruction.
NOTE : For winter storage, ensure that the pump is drained completely to avoid frost damage.

*Note: contained in Service Kit AK0618**

Whale GP0650 V-Pump Mk 6 Hand-Operated Galley Water Pump - Whale V Pump
Mk6

Helpful Hints

(a) If the pump is slow to prime, the cup washer may be worn or the valves are not seating properly.
(b) If the pump won`t pump:

  • Check that the suction line is in the water.
  • Check that the hose connections are secure and there are no air leaks.
  • Check the washers in the pump, they may need to be replaced.

Warranty

This Whale product is covered by 1 years warranty.
Please see the enclosed document for details of our statement of limited warranty.

Munster Simms Engineering Ltd.
2 Enterprise Road, Bangor, Co Down, N Ireland, BT19 7TA
Tel: +44 (0)28 9127 0531 Fax: +44 (0)28 9146 6421
Web:www.whalepumps.com Email: info@whalepumps.com
Ref: 180.30_v6_0617

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals