Magene P505 Dual-Protocol Spider Power Meter User Guide
- June 5, 2024
- Magene
Table of Contents
Magene
Dual-protocol
Spider Power Meter
Quick Start Guide
NOTE Please confirm that the original crank and chain ring fit the required specifications before installation. Do not force installation.
Quick Start Guide
Thank you for purchasing Magene Dual-protocol Spider Power Meter (Hereinafter
referred to as Magene Power Meter) For information regarding spider
installation and adjustment not covered this guide, please refer to your
bicycle dealer’s instruction manual.
If you have any questions about the power meter, please contact us.
E-mail: support@magene.cn ?
Phone: (+86) 400-662-8297
Website: www.magenefitness.com
https://magenefitness.com/topic/utility.html
Unpacking the Box
Take the Magene Power Meter and its parts out of the box and keep the original packaging for future storing and transporting.
The box should contain
- Spider power meter
- Quick start Guide
- Charging line
Connect and Activate the Power Meter
NOTE: Magee Power Meter is not activated and cannot be used normally; the
new product must be activated for the first time. Andriod users need to enter
the google store(iPhone users from the Appstore)to search for the”Magene
Utility”a pp and download it. Follow the prompts to activate your power meter.
NOTE: If activation fails, please click back to enter the device search
list,and recontact to activate.
► 04/ Connect the Power Meter Device
Magee Power Meter can be connected to the power device after activation. Magee
Power Meter is a Bluetooth and ANT+ dual-protocol power meter that is
compatible with ANT+ and Bluetooth devices that support the standardized power
meter protocol. Using this protocol the power meter’s measured data can be
viewed and recorded. Typically, most bike computers can search for and add
power meter equipment in the settings through the
setting>sensors>new>sensors>power meter. NOTE: When searching for the Magene
Power Meter, step on the pedal connected to the power meter crank so that the
power meter can detect the torque, therefore, waking up the power meter from
Sleep mode, start the Bluetooth or ANT+ signal broadcast, and wait for a
device to connect.
NOTE: If there are multiple power meters in the current environment you
need to identify your power meter by ANT-F ID.
► 05/ Calibrating The Power Meter
Zero offset calibration will calibrate the power meter to 0 power when at
rest. When calibrating, please turn the spider in a static state without
external force and use ANT-F Device or Magene Utility for calibration.
► 06/ Peripheral Paring and Functions
Magee Power Meter wirelessly transmits ride information to a bike computer or
receiver that supports ANT-F or Bluetooth. Magene Power Meter logs the
following information as you ride.
- Power 2, Cadence 3, Remaining Battery Capacity 4, Pedal Balance S. Pedal Smoothness This product transmits the following information wirelessly to cycle comput-ers or receivers that support ANT-F or Bluetooth BLE connections
Charging
When you find that the power meter is unable to search for a connection, the power meter may have run out of power. Please charge it as soon as possible. Charging procedure:
- Insert one end of the USB interface of the charging cable into the computer or charger, and a section of the magnetic suction head is slightly close to the power meter body to make it absorb naturally.
- Confirm that the red light of the power meter is always on, and the power meter is in normal charging state. When the battery is fully charged, the light will turn green. NOTE: Do not short circuit the magnetic suction end, and do not adsorb on the metal when it is electrified. Only the USB adapter with an output voltage of 5V can be used for charging.
| P505-51108| P505-51078
---|---|---
power accutacy| 2.%
weight| 128g| 110g
power supply| rechargeable battery
working life| 200h
wireless interface| ANT+ Bluetooth BLE
power range| 0-2500w
cadence range| 20-240rpm
external cadence sensor magnets| none
operating temperature| -10-50C
requires zero-point calibration| yes
Q &A
Please refer to the following if you have any questions in the process of
using Magene Power Meter.
Q: Undisplayed power
A:1. Check to see if activation has been performed
2. Check whether the bike computer or software has been connected
3.If the connection cannot be made, please charge your power meter Q: The
power has obvious deviation A: Do zero offset calibration by your bike
computer or Magene Utility Q: Zero point calibration failure A: Please place
the bicycle on the flat ground and turn around the power meter. Try again. If
none of the above is applicable or the problem is not solved, please consult
online customer service or dealers.
If none of the above is applicable or the problem is not solved, please
consult online customer service or dealers.
► 10/Upgrading the Power Meter’s Firmware
Use your smartphone to scan the QR code to download and install Magento
Utility. Use Magee Utility to connect the power meter to obtain the latest
firmware.
Warnings and Daily Check mornings:
1. Warnings:
- Do not spray the power meter module with high-pressure water when cleaning the bicycle.
- Please lock the crank screw and chain ring screw with the torque required by the manual provided by the original chain ring set manufacturer, otherwise, it may cause the risk of crank or chain ring falling off and affect the power accuracy.
- Do not put the battery into fire or heat, otherwise, it may cause a fire or explode.
- The power meter module is a splash-proof design.Do not soak the power meter module in water.
- Do not subject the power meter module to suffering a severe impact, as this may cause the power meter module to detach or malfunction.
- Use a neutral detergent when washing.The use of alkaline or acidic detergents or thinners may shorten the life of the sensor case.
- The power meter module uses the 2.4G, wireless communication band.The 2.4G signal environment surrounding the object or the surrounding area may cause interference to communications.
- If the signal connection is found to be unstable,try again in an open area. Strong electromagnetic waves are generated by surroundings.
- Do not try to remove the waterproof glue around the power meter module! This will compromise the waterproof performance of the power meter module.
- Performance deterioration caused by natural wear and aging and normal use is not covered by the warranty. 2. Daily Check Items Before Riding Please check the items listed below for riding.ln case of any abnormality,it is recommended to seek professional technicians for maintenance and debugging.
- Are the fastening sections fixed securely?
- Are the any abnormal noises?
- Is there sufficient charge remaining in the battery?
WARRANTY CARD
Warranty Clause product: Thank you for purchasing Magene Dual-Protocol Spider Power Meter. Please carefully read the Warranty Clause. Warranty Clause: This product has passed the strict quality inspection. Failure caused by product quality problem under normal use, we will give free warranty within the warranty period. The warranty period for Magene power meter is 720 days from the activation date. The warranty does not cover any problem that is caused by: conditions, malfunctions or damage not resulting from defects in material or workmanship. The fees of shipping back to us for repair shall not be reimbursed and no fees shall be charged for our shipping back to you. The following situations are not covered by warranty:
- Beyond the warranty period.
- No valid warranty certificate.
- Damage caused by improper use and maintenance.
- The product code on the warranty card does not match the product
- Unauthorized maintenance, modification, use of parts other than the product
- Damage is caused by irresistible factors.
- Damage caused by not using or installing the product in accordance with the instructions.
- Alter warranty card without authorization.
- Other failures and damages caused by non-product design, manufacturing, quality, etc
- Wear and dirt caused by normal operation, such as scratch, bump, etc After the warranty expires, we continue to provide maintenance service for which will be charged a related service fee. The company retains the rights to modify and explain the above-mentioned contents.
Spider Power Meter
Model| P505
| 601230 3.7V
| 180ma*h
| Sg
Manufacturer| Qingdao Magene Intelligence CO.,Ltd.
Address| No.2 AWS, Road, Licang District,
| Qingdao Shandong China
| WSJ Product LTD(for authorities only)
Eschborner LandstraBe 42-SO
60489 Frankfurt am Main,Hessen, Germany
FCC statements:
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE:
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications or changes to this equipment. Such modifications or
changes could void the user’s authority to operate the equipment. This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements, The device can be used in portable exposure conditions without restriction. Federal Communication Commission (FCC) Radiation Exposure Statement Power is so low that no RF exposure calculation is needed.
CE statements:
Declaration of Conformity Hereby, Qingdao Magene Intelligence Technology
Co.,Ltd declares that the radio equipment type P505 is in compliance with
directive 2014/53/EU.
RF exposure information: The device has been evaluated to meet general RF
exposure requirements. The device can be used in portable exposure conditions
without restriction. Radiation Exposure Statement Power is so low that no RF
exposure calculation is needed.
Bluetooth(2402-2480 MHz) Max EIRP is -1.3dBm.
ANT+(2457MHz) Max EIRP is -2.01dBm.
Warranty
Product Data
Customer Name:…………
Address:…………….
Purchase Date:……………….
Dealer (Signature):…………………………
Warranty Information
Maintenance Date | Failure and Solution |
---|
Documents / Resources
|
Magene P505 Dual-Protocol Spider Power
Meter
[pdf] User Guide
P505, 2ALZG-P505, 2ALZGP505, Dual-Protocol Spider Power Meter, P505 Dual-
Protocol Spider Power Meter
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>