BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter Installation Guide

June 9, 2024
BLUE SEA SYSTEMS

BLUE SEA SYSTEMS logo M2 OLED
Digital Monitor
QuickStart Installation Guide
1832 DC Ammeter

Components Included

BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter

360 Panel Mounting Kit 1525 (sold separately)

BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter - fig

bluesea.com/products/1832

Connector Pin Assignment

USB Micro USB Port
8 Pin Connector* Function
1 Required Connection DC Negative
2 Required Connection DC Supply
3 Relay Output
4 Relay Supply
5 Shunt 1 –
6 Shunt 1 +
7 Shunt 2 –
8 Shunt 2 +

*The 8 pin low voltage connector supports wire sizes from 16-26 AWG

M2 Meter Navigation

Screen Menu Functions
Press any button to bring up the menu.

  1. After start-up, press any button to access the menu.
  2. Press the UP or DOWN arrow buttons to scroll through menu windows.
  3. To set alarms and for more detailed information, see the online manual at bluesea.com/products/1832

BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter - fig 1

System Overview

BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter - fig 2

For the online manual that includes other configurations, go to bluesea.com/products/1832

Installation Steps

  1. Choose meter mounting style and location.

  2. Prepare mounting hole using cutout templates.

  3. Using wiring diagram:
    • Install provided 500A/50mV Shunt.
    • Install busbar, if needed.
    • Make all connections to the meter’s connector.
    Do not put fuses into fuse holders at this time.

  4. Plug wired connector into the meter.

  5. Insert fuses into fuse holders, making the fuse to
    Pin 2 (DC Supply) Last.

Basic Meter Setup

  1. If using the included 8255 500A/50mV shunt, no setup is required.
  2. If you are only monitoring one shunt, you may want to shut off the other input.
  3. To do this, go to the Setup Menu.
  4. Scroll to the unused input (either DC1 or DC2)
  5. Set Enabled to OFF.
  6. For more detailed information or instructions regarding Alarm Setup, Relay Setup, or using a different sized shunt, see the full instructions found at bluesea.com/products/1832.

Mounting Options

Flat Mount

BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter - fig 3

Surface Mount

BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter - fig 4

Mounting Templates

BLUE SEA SYSTEMS 1832 DC Ammeter M2 DC Ammeter - fig 5

WARNING
The WARNING symbol refers to possible injury to the user or significant damage to the monitor if the user does not follow the procedures.
CAUTION
The CAUTION symbol refers to restrictions and rules with regard to preventing damage.

WARNING
If you are not knowledgeable about electrical systems, have an electrical professional install this unit. The diagrams in these instructions pertain to the installation of the unit  and not to the overall wiring of the vessel.
Verify that no other DC or AC sources are connected to the vessel’s wiring before installing the unit.

CAUTION
The back of the unit is not waterproof. Do not install where the back of the monitor is exposed to water.

Warranty
The M2 OLED Digital Meters come with a 5 year manufacturer’s warranty. This means the meter is warranted to be free from defects in materials or workmanship for 5  years from the date of first purchase. The warranty is limited solely to the cost of repair or replacement of the M2 Meter product. Costs associated with labor or shipping of  the defective parts are not covered. Blue Sea Systems cannot accept liability for damage due to the misuse of the M2 Meter.

Click here for more information at bluesea.com/products/1832