Carrier 42TVAB010 Split Type Air Conditioner Owner’s Manual

June 5, 2024
Carrier

CARRIER LOGO

Carrier 42TVAB010 Split Type Air Conditioner

Carrier 42TVAB010 Split Type Air Conditioner PRODUCT
IMAGE

PRECAUTIONS FOR SAFETY

  • Read the precautions in this manual carefully before operating the unit.
  • This appliance is filled with R32.

Warning indications on the air conditioner unit.

Warning indication Description

CAUTION
BURST HAZARD Open the service valves before the operation, otherwise there might be the burst.| CAUTION
BURST HAZARD
Open the service valves before the operation, otherwise there might be the burst.

  • Keep this manual where the operator can easily find it.
  • Read the precautions in this manual carefully before operating the unit.
  • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • The precautions described herein are classified as DANGER, WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.

DANGER

  • Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. Ask the dealer or the specialist to do this.
  • Turning off the power supply will not prevent potential electric shock.
  • The appliance shall be installed in accordance with national wiring regulation.
  • Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring.
  • The appliance must be stored in a room without continuously operating ignition sources (for example, open flames, an operating gas appliance or an operating electric heater).
  • In order to avoid fire, explosion or injury, do not operate the unit when harmful gases (e.g. flammable or corrosive) are detected near the unit.

WARNING

  • Do not expose your body directly to cool or warm air for a long time.
  • Do not insert your finger or any article into the air inlet/outlet.
  • When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power supply or turn off the breaker.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • The air conditioner must be installed, maintained, repaired and removed by a qualified installer or qualified service person. When any of these jobs is to be done, ask a qualified installer or qualified service person to do them for you.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Do not use any refrigerant different from the one specified (R32) for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  •  Be aware that refrigerants may not contain an odour.
  •  Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flames, sparks, or other sources or ignition. Else, it may explode and cause injury or death.
  • Appliance and pipe-work shall be installed, operated and stored in a room with a floor area larger than Amin m2.
    How to get Amin m2 : Amin = (M / (2.5 x 0.22759 x h0))2
    M is the refrigerant charge amount in appliance in kg, h0 is the installation height of the appliance in m: 0.6 m for floor standing/1.8 m for wall
    mounted/1.0 m for window mounted/2.2 m for ceiling mounted.
    (For these units recommend installation height 2.5 m)

CAUTION

  • Do not wash the unit with water. It may cause an electric shock.
  • Do not use this air conditioner for other purposes such as preserving food, breeding animal, etc.
  • Do not step or put anything on the indoor/outdoor unit. It may cause an injury or damage the unit.
  • Do not touch aluminum fin because it may cause an injury.
  • Before cleaning the unit, turn off the main switch or the circuit breaker.
  • When the unit won’t be used for a long time, turn off the main switch or the circuit breaker.
  • It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time.
  • The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.

INDOOR UNIT DISPLAY

  1. Wi-Fi access
  2. ECO
  3.  PURE
  4. Timer
  5.  Operation mode

PREPARATION BEFORE USE Preparing Filters

Preparing Filters

  1. Open the air inlet grille and remove the air
  2. Attach the (see detail in the Installation Manual).

Loading Batteries (when use wireless operation.)

  1. Remove the slide
  2. Insert 2 new batteries (AAA type) following the (+) and (–) positions.

Remote Control Reset

  1. Remove the
  2. Press .
  3. Insert the

AIR FLOW DIRECTION

  1. Press : Move the louver in the desired vertical direction.

  2. Press : Move the louver in the desired horizontal direction.

  3. SWING operation can be selected from MENU button

    • Swing off
    • Vertical(Up-Down) Swing
    • Horizontal (Left-Right) Swing
    • Vertical and Horizontal Swing
    • HADA CAREFLOW
  • Vertical (Up-Down) swing

  • Horizontal (Left-Right) swing

  • HADA Care flow

Note:

  • Do not move the louver manually by others.
  • The louver may automation positioning by some operation mode.

REMOTE CONTROL

  1. Infrared signal emitter
  2. Start/Stop button
  3. Mode select button
  4. Temperature button
  5. Fan speed button
  6. Menu select button
  7. Set louver Up-Down button
  8. Set louver Left-Right button Check button
    Check button under battery cover

COOLING / FAN ONLY OPERATION

  1. Press Mode : Select Cool , or Fan only .

  2. Press Tem : Set the desired temperature. Min. 17°C, Max. 30°C.
    Fan Only: No temperature indication

  3.  Press Fan : Select AUTO, LOW , LOW+ , MED , MED+ , HIGH or Quiet.

AUTOMATIC OPERATION

To automatically select cooling, heating, or fan only operation

  1. Press : Select Auto A.
  2.  Press : Set the desired temperature. Min. 17°C, Max. 30°C.
  3.  Press : Select AUTO, LOW , LOW+ , MED , MED+ , HIGH or Quiet.

DRY OPERATION

For dehumidification, a moderate cooling performance is controlled
automatically.

  1. Press Mode : Select Dry .
  2.  Press Temp : Set the desired temperature. Min. 17°C, Max. 30°C.
    Note: DRY mode fan speed is set to Auto only

For select more setting of Air conditioner such as Louver select Hi Power, OFF Timer and other use MENU button.
LOUVER SWING and HADA CARE FLOW OPERATION
Comfortable air flow can select from feature.

Louver swing operation:
To distribute air flow in both vertical and horizontal by swing the louver automatically.

HADA care flow operation:
Air flow upward to the ceiling, provide Indirect air flow to body and homogenize room temperature.
Note: During HADA CARE FLOW mode, FIX button cannot active.

Louver Swing and HADA Care Flow Operation Setting

  1. Press MENU button for enter menu selection

During triangle mark blink can select menu by press TEMP. button.

  1. Enter Louver set by press MENU button again. triangle mark will stop blink and setting feature will be blink instead.

  2. Select Louver swing or HADA CARE FLOW by press TEMP. button.
    Select Louver swing or HADA CARE FLOW by press TEMP
button

  3. Confirm selected feature by press MENU button again.
    Confirm selected feature by press MENU button again. When feature had selected will return to menu selection display triangle mark will blink .

  4.  Leave from menu setting display by select exit and press menu button.
    Leave from menu setting to normal display (no triangle and feature blink).

SILENT OPERATION (Outdoor Unit)

Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in nighttime. By this feature, the cooling capacity will be optimized to deliver such silent experience. The silent operation can be selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2

Silent 1:

  • Though operating silently, the Cooling capacity is still prioritized to ensure having sufficient comfort inside the room.
  •  This setting is a perfect balance between the Cooling capacity and the Sound level of outdoor unit.

Silent 2:

  • Compromising the Cooling capacity to the Sound level in any circumstance where the outdoor unit’s sound level is highly prioritized.
  • This setting has a purpose to reduce the maximum sound level of outdoor unit.

Note: While activating of Silent operation, inadequate cooling capacity may occur.

Silent Operation Setting
  1. Press MENU button for enter menu selection.
    During triangle mark blink can select menu by press TEMP. button.

  2. Enter SILENT set by press MENU button.
    triangle mark will stop blink and setting feature will be blink instead.

  3. Select SILENT operation by press TEMP. button.

  4. Confirm selected feature by press MENU button again.
    Silent Operation Setting 05When feature had selected will return to menu selection display triangle mark will blink

  5.  Leave from menu setting display by select EXIT.

ECO OPERATION

To automatically control room temperature to save energy (except in DRY and FAN ONLY mode)

  1. Press MENU button for enter menu setting and press TEMP. button to select ECO.
    Hi POWER OPERATION 012. Confirm selected feature by press MENU button again.

3. Leave from menu setting display by select EXIT.
Hi POWER OPERATION 03
Note: Cooling operation; the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase)..

TIMER OFF OPERATION

To set the timer OFF when the air conditioner is operating.

  1. Press MENU button for enter menu setting and press TEMP. button to select TIMER OFF.
    TIMER OFF OPERATION 01

  2. Enter TIMER set by press MENU button.
    triangle mark will stop blink and setting feature will be blink instead.

  3. Select TIMER OFF by press TEMP. button.
    Can select TIMER OFF from 0.5 – 12hrs.

  4. Confirm TIMER OFF by press MENU button.TIMER OFF OPERATION 04

  5. Leave from menu setting display by select EXIT.
    Note:  The setting will be saved for the next same operation.

Cancel TIMER OFF
  1. During TIMER OFF already set (no.5) press MENU button and press TEMP. button to select TIMER OFF.
    Cancel TIMER OFF 01

  2. Press MENU button again will cancel TIMER OFF.
    Cancel TIMER OFF 02

  3. Leave from menu setting display by select EXIT.
    Cancel TIMER OFF 03

PLASMA ION OPERATION

Capture efficiency of floating impurities in the air is accelerated by plasma ion contaminates such as bacteria, odor, smoke, dust and virus are caught and deactivated by Plasma Ion.

  1. Press MENU button for enter menu setting and press TEMP. button to select PURE.
    PLASMA ION OPERATION 01

  2. Confirm selected feature by press MENU button again.
    PLASMA ION OPERATION 02

  3. Leave from menu setting display by select EXIT.

Note: Plasma Ion operation dose not remove harmful substances from cigarette smoke (carbon monoxide etc.). Open a window occasionally for ventilation.

POWER-SELECTION OPERATION

This function is used when the circuit breaker is shared with other electrical appliances. It limits the maximum current and power consumption to 100%, 75%, or 50% and can be implemented by POWER-SELECTION. The lower percentage, the higher saving and also longer compressor lifetime.

  • Due to the reason that POWER-SELECTION function limits the maximum current, inadequate cooling capacity may occur.
  1. Press MENU button for enter menu setting and press TEMP. button to select POWER-SEL
    POWER-SELECTION OPERATION 01

  2. Enter POWER-SEL setting by press MENU button again.
    POWER-SELECTION OPERATION 02

  3. Select POWER-SEL level by press TEMP. button.

  4. Confirm POWER-SEL level by press MENU button.

  5. Leave from menu setting display by select EXIT.

DISPLAY LAMP BRIGHTNESS ADJUSTMENT

To decrease the display lamp brightness or turn it off.

  1. Press and hold for 3 seconds until brightness level or is shown on remote control LCD then release the button.
  2. Press Rise or Decrease to adjust brightness in 4 levels.
    DISPLAY LAMP BRIGHTNESS ADJUSTMENT
  • In the examples of and , the lamp illuminates for 5 seconds before going off.

AUTO RESTART FUNCTION SETTING

This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure.

Information
The product is shipped with Auto Restart function in the ON position.
Turn it OFF if this function is not required.
How to turn OFF the Auto Restart Function

  • Press and hold the [OPERATION] button on the indoor unit for 3 seconds
    (3 beep sounds but OPERATION lamp does not blink).
    How to turn ON the Auto Restart Function

  • Press and hold the [OPERATION] button on the indoor unit for 3 seconds
    (3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
    Notes :

  •  In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does not activate.

SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)

To protect bad smell caused by the humidity in the indoor unit.

  1. If the button is pressed once during “Cool” or “Dry” mode, the fan will continue to run for other 30 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit.
  2. To stop the unit immediately, press the more 2 times within 30 seconds.

TEMPORARY OPERATION

In case of the misplaced or discharged remote control

  • Pressing the RESET button, the unit can start or stop without using the remote control.
  • Operation mode is set on AUTOMATIC operation, preset temperature is 24°C and fan operation is automatic speed

OPERATION AND PERFORMANCE

  1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON.
  2. Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/
    contraction of plastic.

Air conditioner operating conditions

Temp.
Operation| **Outdoor Temperature| ****Room Temperature**
---|---|---
Cooling| ‒10°C ~ 46°C| 21°C ~ 32°C
Dry| ‒10°C ~ 46°C| 17°C ~ 32°C

MAINTENANCE

Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control

  • Clean the indoor unit and the remote control with a wet cloth when needed.
  •  No benzine, thinner, polishing powder or chemically-treated duster.

Air filters
Clean every 2 weeks.

  1. Open the air inlet grille.
  2. Remove the air filters.
  3. Vacuum or wash and then dry them.
  4. Reinstall the air filters and close the air inlet grille.

TROUBLESHOOTING (CHECK POINT)

The unit does not operate. Cooling or Heating is abnormally low.
  • The power main switch is turned off.
  • The circuit breaker is activated to cut off the power supply.
  •  Stoppage of electric current
  • ON timer is set.

|

  • The filters are blocked with dust.
  • The temperature has been set improperly.
  • The windows or doors are opened.
  • The air inlet or outlet of the outdoor unit is blocked.
  • The fan speed is too low.
  • The operation mode is FAN or DRY.
  • POWER SELECTION function is set 75% or 50%(This function is depend on remote controller).

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals