metabo ASC 55 Li-ion Battery Charger Instruction Manual
- June 5, 2024
- metabo
Table of Contents
- metabo ASC 55 Li-ion Battery Charger
- DIAGRAMS
- Declaration of Conformity
- Specified Conditions of Use
- General Safety Information
- Special Safety Instructions
- Overview
- Initial Operation
- Use
- Faults
- Repairs
- Environmental Protection
- Technical Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
metabo ASC 55 Li-ion Battery Charger
DIAGRAMS
Declaration of Conformity
We, being solely responsible: Hereby declare that these chargers, identified by type and serial number 1), meet the requirements of all relevant directives 2) and standards 3). Technical documents for 4)
Specified Conditions of Use
Chargers are only suitable for charging Metabo and CAS (Cordless Alliance
System) battery packs. This device is not designed for use by persons
(including children) with physical, sensory or mental disabilities, or with
insufficient experience and/or knowledge, unless they are supervised by a
person responsible for their safety, or have received instructions on how to
use the device by this person.
ASC 30-36 is suitable for charging Li-ion battery packs (14.4 V – 36 V, 1.3 Ah
– 8.0 Ah, 4- 10 cells).
ASC 55 is suitable for charging Li-ion battery packs (12 V – 36 V, 1.3 Ah –
8.0 Ah, 3- 10 cells).
ASC 145 is suitable for charging Li-ion battery packs (12 V – 36 V, 1.3 Ah –
8.0 Ah, 3- 10 cells).
ASC ultra is suitable for charging Li-ion battery packs (corresponding to the
print on the tool, either 14.4 V – 36 V, 1.3 Ah – 8.0 Ah, 4- 10 cells, or 12 V
– 36 V, 1.3 Ah – 8.0 Ah, 3- 10 cells).
SC 60 Plus is suitable for charging Li-ion battery packs (14.4 V – 18 V, 1.3
Ah – 8.0 Ah, 4- 10 cells).
SC 30 is suitable for charging Li-ion battery packs (12 V – 18 V, 1.3 Ah – 8.0
Ah, 3- 10 cells).
ASC 55 is suited for charging NiCd battery packs (12V, 1.7Ah, 10 cells).
NOTE:
Never attempt to charge batteries that are not rechargeable. Danger of
explosion!
The user bears sole responsibility for any damage caused by inappropriate use. Generally accepted accident-prevention regulations and accompanying safety instructions should be observed.
General Safety Information
WARNING
- Read the operating instructions to reduce the risk of injury.
- Read all safety warnings and instructions
Failure to follow all safety warnings and instructions may result in electric shock, fire and/or serious injury. Keep all safety instructions and information for future reference. Before using the charger, carefully read through and familiarise yourself with all the enclosed safety information and the Operating Instructions. Keep all enclosed documentation for future reference, and pass on your charger only together with this documentation.
Special Safety Instructions
- If battery fluid leaks out and comes into contact with your skin, rinse immediately with plenty of water. If battery fluid leaks out and comes into contact with your eyes, wash them with clean water and seek medical attention immediately!
- Do not recharge a fully charged battery pack!
- Only for use in indoor rooms.
- Protect the charger from moisture.
- Never allow children to use the device.
- Children should be supervised to ensure that they do not play with the tool.
- Keep children away from the battery charger and the working area!
- Keep your battery charger out of reach of children!
- Pull out the mains plug immediately if the battery charger starts to smoke or flames emerge!
- Do not insert objects into the ventilation slots on the battery charger – there is a danger of electric shocks and short circuits!
- Do not use faulty battery packs.
- In areas with high metal dust exposure do not charge any battery packs with AIR COOLED chargers.
Overview
See page 2. The illustrations are regarded as exemplary for all devices.
- Battery pack (not in scope of delivery)
- Sliding seat
- Operation display
- Warning display
Initial Operation
Before commissioning, check that the rated mains voltage and mains frequency stated on the type plate match your power supply. Devices like these that generate direct current can influence simple earth leakage protection devices. Use a type F or better, with a release current of max. 30 mA. Before commissioning the charger, ensure that the air slots are free. The minimum distance to other objects is 5 cm!
Self-test
Plug in.
The warning display (4) and the operating indicator (3) light up one after the
other for approx. 1 second and the installed fan runs for approx. 5 seconds.
Use
Charging battery pack
Push the battery pack completely to the stop on the sliding seat (2). The
operating indicator (3) flashes.
Note: To have the charge level displayed on Li-ion battery packs, first take
the battery pack out of the charger and then press the button on the battery
pack.
Conservation charge
Once the charging process has finished, the battery charger automatically switches to conservation mode. The battery pack can remain in the battery charger and is therefore always ready for use. The operating display (3) lights up continuously.
Faults
Warning display (4) lights up continuously
Battery pack is not charged. Excessive/insufficient temperature. When the temperature of the battery pack is between 0 °C and 50 °C, the charging process begins automatically.
Warning display (4) flashes
- Battery pack is defective. Remove the battery pack immediately from the charger.
- The battery pack was not pushed correctly onto the sliding seat (2). See chapter 7.1.
Repairs
Repairs to the charger must only be carried out by qualified electricians. If the mains connection cable of this device is damaged, it must be replaced by the manufacturer or the Customer Service department of the manufacturer or a similarly qualified person to prevent endangering personnel and property. If you have Metabo charges that require repairs, please contact your Metabo service center. See www.metabo.com for addresses.
Environmental Protection
Observe national regulations on environmentally compatible disposal and on the recycling of disused machines, packaging and accessories. Only for EU countries: never dispose of power tools in your household waste! According to European Directive 2012/19/EU on Waste from Electric and Electronic Equipment and implementation in national law, used power tools must be collected separately and recycled in an environmentally-friendly manner.
Technical Specifications
- U = voltage ranges of the battery packs
- C = battery pack capacity
- IC = charging current
- t = charging time
Depending on the residual capacity and the temperature of the battery pack, real charging times may deviate from the specifications. Recommended ambient temperature when charging: 0 °C to 50 °C Changes due to technological progress reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>