ELKOep RFDEL-71B-SL Universal Dimmer
WARNING
- Newly produced drivers work in the RFIO2 data protocol mode. These driv-ers are loaded in the actuators in a different way than before. Among other things, it eliminates the risk of inadvertently loading another randomly occur-ring controller within range.
- Drivers can still be switched to so-called compatibility mode, and loaded in a simpler (older way)
- The mode in which the controller is located is indicated after inserting the battery and after 5 seconds have passed, at which the LED is lit by subsequent different intervals of flashing of the LED.
RFIO2 mode
Double flash (flash, flash, gap, flash, flash) Compatibility mode = Flash fast (flash, flash, flash, flash, flash)
- If you do not want to change the function of the controller, you must not press any buttons during this time.
- If we need to change the operating mode of the controller, after inserting the battery, when the LED is permanently lit, we press at the same time:
- RF KEY-40/60 button 1 and 3
- RFWB-20/40 button 1 and 2
- RFGB-20/40 button 1 and 2
- RFIM 20/40 – the inputs 1 and 2 are activated simultaneously
you hold the buttons until the LED starts to signal the changed mode (double fl ash or fast fl ash). After that, the buttons must be released. The selected mode of the function is stored in memory and after replacing the battery, the controller continues to operate in the same mode.
NOTE: after each removal of the battery, we press one of the buttons several times to discharge the device and reinsert the battery
UPDATE THE CONTROLLER ACTUATORS IN RFIO2 MODE
If the controller is used in RFIO2 mode, then to update the controller
actuators, it is necessary to switch not only the actuator to the update mode
(according to the instructions for the actuator), but also the controller in
the following way: You remove the battery from the controller, press some of
the buttons several times to discharge the device, and reinsert the battery.
At the moment when the LED lights up, you press the 1 button and hold it down
until the controller starts signaling the updating mode with a short fl ashing
of the LED. Then you release the button and the controller now works in RFIO2
update mode. To end the update mode, you remove the battery, press one of the
buttons several times, and then reinsert the battery. Now you do not press any
button and the controller starts again in RFIO2 operating mode,
Characteristics
The universal built-in dimmer is used to regulate light sources:
-
R – classic lamps.
-
L – halogen lamps with wound transformer.
-
C – halogen lamps with electronic transformer. ESL – dimmable energy-efficient fluorescent lamps. LED – LED light sources (230V).
-
They can be combined with detectors, controllers, iNELS RF Control or system components.
-
The BOX design lets you mount it right in an installation box, a ceiling or light cover.
7 light functions – smooth starting up or running out with time setting 2 sec to 30 min + additional function SWITCH OFF -
Setting of minimum brightness eliminates blinking of LED and ESL light sources
-
Universal dimmer may be controlled by up to 25 channels
-
Control input “S” for connection of the existing wired pushbutton
-
Programming pushbutton on the element can also be used as manual control of the output
-
For the elements marked as iNELS RF Control2 (RFIO2), it is possible to set the function• For com-ponents labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.
-
Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
-
Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2).
Assembly
- mounting in an installation box (even under the existing button / switch)
- mounting into a light cover
- ceiling mounted
Connection
Radiofrequency signal penetration through various construction materials
For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures
Indication, manual control
- LED STATUS – an indication of the device status.
- Manual control is performed by pressing the PROG button for less than 1s.
- Programming is performed by pressing the PROG button for more than 1s.
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.
Compatibility
The device can be combined with all system components, controls and devices of
iNELS RF Control and iNELS RF Control2.
The detector can be assigned an iNELS RF Control2 (RFIO2) communication
protocol.
Programming with RF control units
The address listed on the front of the actuator is used for programming and controlling actuators by RF control units.
SETUP mode (load type selection and minimum brightness setting)
Load type setting and minimum brightness setting
-
Switching over to the SETUP mode can be carried out by quick fourfold click on the programming pushbutton.(4x PROG < 1s)
-
The choice of the load type is the fi rst function of the SETUP mode. In this mode, the output brightness changes automatically between 0% and 100% and the LED on the instrument indicates the actually chosen load type:
- – R, C mode – fourfold fl ash
- – L mode – double fl ash
The mode can be changed to the inverse mode by pressing the pushbutton on any controller that is already learned.
-
Setting of minimum brightness is the other function of the SETUP mode. This function can be chosen by short pressing the PROG pushbutton. This mode is indicated by the same blinking mode as the learning mode (LED blinking 1x per second). Minimum brightness can be set using any already learned control. Another short pressing the PROG push button closes the SETUP mode and the preset type of the load and minimum brightness are saved into memory.
Functions and programming with RF transmitters
Light scene function 1
Description of light scene 1
- By pressing the programmed button for less than 0.5s, the light illuminates; it goes out by pressing again.
- By pressing the programmed button for more than 0.5s, fl uid brightness regulation will occur. After releasing the button, the brightness level is saved in the memory, and pressing the button shortly later will switch the light on /off to this intensity.
- It is possible to readjust the change in intensity at any time by a long press of the programmed button.
- The actuator remembers the adjusted value even after disconnecting from the power supply.
Programming
- Press of programming but-ton on actuator RFDEL-71B-SL for 1 second will activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.
- A press of your selected button on the RF transmitter assigns the function light scene 1.
- Press of programming but-ton on actuator RFDEL-71B-SL shorter then 1 second will fi n-ish programming mode. The LED lights up according to the pre-set memory function.
Light scene function 2
Description of light scene 2
- By pressing the programmed button for less than 3s, the light illuminates; it goes out by pressing again.
- In order to limit undesirable control of brightness, fluid brightness control occurs only by pressing a programmed button for over 3s. After releasing the but-ton, the brightness level is saved in the memory, and pressing the button shortly later will switch the light on / off to this intensity.
- It is possible to readjust the change in intensity at any time by pressing the programmed button for over 3s.
- The actuator remembers the adjusted value even after disconnecting from the power supply.
Programming
- Press of programming but-ton on actuator RFDEL-71B-SL for 1 second will activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.
- Two presses of your selected button on the RF transmitter as-signs the function light scene 2 (must be a lapse of 1s between individual presses).
- Press of programming but-ton on actuator RFDEL-71B-SL shorter than 1 second will fi n-ish programming mode. The LED lights up according to the pre-set memory function.
Light scene function 4
Description of light scene
- By pressing the programmed button for less than 0.5s, the light illuminates. By pressing the button shortly again, the light will continuously switch off for 3 seconds (at 100% brightness).
- By pressing the programmed button for more than 0.5s, fluid brightness regulation will occur. After releasing the button, the brightness level is saved in the memory, and pressing the button shortly later will switch the light on/off to this intensity.
- It is possible to readjust the change in intensity at any time by a long press of the programmed button.
- The actuator remembers the adjusted value even after disconnecting from the power supply.
Programming
- Press of programming but-ton on actuator RFDEL-71B-SL for 1 second will activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.
- Four presses of your selected button on the RF transmitter as-signs the function light scene 4 (must be a lapse of 1s between individual presses).
- Press of programming but-ton on actuator RFDEL-71B-SL shorter then 1 second will fi n-ish programming mode. The LED lights up according to the pre-set memory function.
Function sunrise
Description of sunrise function
After pressing the programmed button, the light begins to illuminate in the pro-grammed time interval in a range of 2 seconds to 30 minutes.
Programming
- Press of programming but-ton on actuator RFDEL-71B-SL for 1 second will activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.
- Assignment of the sunrise function is performed by fi ve presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
- Press of programming button for longer than 5 seconds, will activate the actuator into timing mode. LED flashs 2x in each 1s interval. After releasing the button, the time of the sun-rise function begins to count down (period of complete illumination of the light).
- After the desired time has elapsed, the timing mode ends by pressing the button on the RF transmitter, to which the sunrise function is assigned. This stores the set time interval into the actuator memory.
- Press of programming but-ton on actuator RFDEL-71B-SL shorter than 1 second will finish programming mode. The LED lights up according to the pre-set memory function.
Function sunset
Description of sunset function
After pressing the programmed button, the light begins to dim in the pro- grammed time interval in a range of 2 seconds to 30 minutes.
Programming
- Press of programming but-ton on actuator RFDEL-71B-SL for 1 second will activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.
- Assignment of the sunset function is performed by six presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
- Press of programming button for longer than 5 seconds, will activate the actuator into timing mode. LED flashs 2x in each 1s interval. After releasing the button, the time of the sun-set function begins to count down (period of complete dimming of the light).
- After the desired time has elapsed, the timing mode ends by pressing the but-ton on the RF transmitter, to which the sunset function is assigned. This stores the set time interval into the actuator memory.
- Press of programming but-ton on actuator RFDEL-71B-SL shorter then 1 second will fi nish programming mode. The LED lights up according to the pre-set memory function.
Function ON/OFF
Description of ON/OFF
If the light is switched off , pressing the programmed button will switch it on. If the light is switched on, pressing the programmed button will switch it off .
Programming
- Press of programming but-ton on actuator RFDEL-71B-SL for 1 second will activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.
- Seven presses of your selected button on the RF transmitter assigns the function ON/OFF (must be a lapse of 1s between individual presses).
- Press of programming but-ton on actuator RFDEL-71B-SL shorter then 1 second will fi n-ish programming mode. The LED lights up according to the pre-set memory function.
Function switch off
Description of switch off
The dimmer output switches off by pressing the button.
Programming
- Press of programming but-ton on actuator RFDEL-71B-SL for 1 second will activate actuator RFDEL-71B-SL into programming mode. LED is fl ashing in 1s interval.
- Eight presses of the selected button on the RF transmitter as-signs the function OFF (must be a lapse of 1s between individual presses).
- Press of programming but-ton on actuator RFDEL-71B-SL shorter than 1 second will fi n-ish programming mode. The LED lights up according to the pre-set memory function.
Delete actuator
Deleting one position of the transmitter
- By pressing the programming button on the actuator for 5 seconds, the deletion of one transmitter activates. LED flashs 4x in each 1s interval.
- Pressing the required button on the transmitter deletes it from the actuator’s memory.
- To confi rm deletion, the LED will confi rm with a fl ash long and the component returns to the operating mode.
Deleting the entire memory
- By pressing the programming button on the actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED fl ashs 4x in each 1s interval.
- The actuator goes into the programming mode, the LED fl ashes in 0.5s intervals (max. 4 min.).
- You can return to the operating mode by pressing the Prog button for less than 1s. The LED lights up according to the pre-set memory function and the component returns to the operating mode.
Control with an external button
The function for the external “wired” pushbutton can be assigned in the same way as for the wireless pushbutton, i.e. by pressing the programming pushbutton on the actor and respec-tive number of control pushbutton pressings.
Additional information
- Do not mix more types of light sources!
- Do not try to use energy-saving bulbs that are not labeled as dimmable!
- Incorrect setting of the type of light source aff ects the extent and dimming (but no damage to the dimmer or load).
- Incorrect setting of the type of load can cause overheating of the dimmer.
- The maximum number of light sources depends on their internal structure.
Warning
The instruction manual is designated for mounting and also for the user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. The trouble-free function of the device also depends on transportation, storing, and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting the installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to the transmissivity of RF signal, observe the correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation in exteriors and humid spaces. They must not be installed into metal switchboards and into plastic switchboards with metal doors – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – the radiofrequency signal can be shielded by an obstruction, interfered, a battery of the transceiver can get fl at etc. and thus disable the remote control.
Technical parameters
Supply voltage: | 230 V AC |
---|---|
Supply voltage frequency: | 50-60 Hz |
Apparent power: | 5 VA / cos φ = 0.1 |
Dissipated power: | 0.5 W |
Supply voltage tolerance: | +10/ -15 % |
Connection: | 4 – wire, with NEUTRAL / 4-vodičové, s “NULOU“ |
Output | |
Dimmed load: | R, L, C, LED, ESL |
Contactless: | 2 x MOSFET |
Load capacity:* | max. 300 W* |
Control | |
Wireless: | up to / až 25 kanály |
Communicationprotocol: | RFIO2 |
Frequency: | 866-922 MHz |
Repeater function: | ano |
Range: | až 200 m |
Manualcontrol: | tlačítko PROG (ON/OFF) |
External button / switch: | yes / ano |
Other data | |
Operating temperature: | -15 až + 45 °C |
Working position: | any / libovolná |
Mounting: | free at lead-in wires / volné na přívodních vodičích |
Protection: | IP40 |
Overvoltage category: | III. |
Contamination degree: | 2 |
Connection: | screwless terminals / bezšroubové svorky |
Connecting conductor: | 0.2-1.5 mm2 solid/flexible |
Dimensions: | 43 x 44 x 22 mm |
Weight: | 30 g |
Related standards: | EN 60730, EN 63044, EN 300 220, EN 301 489 |
* loadability of power factor cos φ=1
Power factor of dimmable LED and ESL bulbs moves in the following range: cos φ
= 0.95 to 0.4. Approximate value of the maximal load is achieved by
multiplication of loadability of dimmer and power factor connected to a light
source.
Attention:
When you install an iNELS RF Control system, you have to keep a minimal
distance 1 cm between each unit. Between the individual commands must be an
interval of at least 1s.