Nedis ACMB1WT9 | ACMB1WT12 Local Air Conditioner User Manual
- June 5, 2024
- nedis
Table of Contents
ACMB1WT9 | ACMB1WT12 Local Air Conditioner
User Manual
Preface
Thank you for purchasing the Nedis ACMB1WT9 | ACMB1WT12.
This document is the user manual and contains all the information for correct, efficient and safe use of the product.
This user manual is addressed to the end user. Read this information carefully before installing or using the product.
Always store this information with the product for use in the future.
Product description
Intended use
The Nedis ACMB1WT9 | ACMB1WT12 is a local air conditioner used for cooling and dehumidifying rooms.
The product is exclusively intended as a local air conditioner for domestic, indoor use.
The product is not intended for professional use.
This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the product in a safe way and understand the hazards involved. Children shall not play with the product. Cleaning and user maintenance shall not be done by children without supervision.
This product is intended for use in household environments for typical housekeeping functions that may also be used by non-expert users for typical housekeeping functions, such as: shops, offices other similar working environments, farm houses, by clients in hotels, motels and other residential type environments and/or in bed and breakfast type environments.
Any modification of the product may have consequences for safety, warranty and proper functioning.
Specifications
Product
|
Local Air Conditioner
---|---
Article number
|
ACMB1WT9
|
ACMB1WT12
Dimensions (l x w x h)
|
42 x 72 x 36 cm
Weight
|
27.5 kg
Input voltage
|
220 – 240 VAC ; 50 / 60 Hz
Required power
|
1010 W
|
1357 W
Energy class
|
A
Energy efficiency ratio (EER)
|
2.6
Noise level
|
< 65 dB
Cooling capacity
|
9000 BTU
|
12000 BTU
Room size capacity *
|
18 – 27 m²
|
24 – 36 m²
Air circulation
|
400 m3/h
Dehumidification
|
24 l/day
Refrigerant
|
R290 / 230 g
Power plug
|
Schuko CEE 7/7
- The performance of the air conditioner is subjected to many factors like floor space, ceiling height, level of isolation and number of windows. The data mentioned is based on a space with low heat loads.
Main parts (image A)
A
1. Remote control holder
2. Continuous drainage outlet
3. Air outlet
4. Power cable storage
5. Air intake
6. Manual drainage outlet
7. Power cable
8. Exhaust hose
9. Exhaust nozzle
10. Exhaust hose connector
11. Window kit
12. Control panel
13. Swing louvers
14. Remote control
15. Window kit fasteners
16. Exhaust nozzle screw
Safety instructions
WARNING
|
Contains one or more (extremely/highly) flammable components.
---|---
|
Contains one or more (extremely/highly) flammable components.
---|---
- Ensure you have fully read and understood the instructions in this document before you install or use the product. Keep the packaging and this document for future reference.
- Only use the product as described in this manual.
- This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the product in a safe way and understand the hazards involved. Children shall not play with the product. Cleaning and user maintenance shall not be done by children without supervision.
- Close supervision is necessary when the product is used by or near children, animals or infirm persons. Do not allow children to play with it or touch it.
- Keep the product out of reach from children.
- Do not use a damaged or defective product, but return it for repair or replacement.
- Do not expose the product to water, rain, moisture or high humidity.
- If the product is immersed in water, do not touch the product or the water.
- Shut off the main power grid and carefully remove the plug from the power outlet.
- After the product has been immersed or covered in water or other liquids, do not use the product again.
- Keep the product away from heat sources. Do not place the product on hot surfaces or near open flames.
- Do not use the product near explosive or flammable materials.
- Do not insert any objects into the product.
- Do not obstruct or cover the product’s air inlet or outlet grid.
- The appliance shall be installed in accordance with national wiring.
- Always disconnect the product from the power outlet when cleaning or moving the product.
- Do not pull the power cable to move the product.
- Unplug the product from the power source and other equipment if problems occur.
- Do not unplug the product by pulling on the cable. Always grasp the plug and pull.
- Switch off the main power switch before unplugging the power cord.
- Do not use the product when the cord or plug is damaged.
- Make sure that the electrical supply in your area matches a voltage of 220 – 240 VAC and a frequency of 50 Hz.
- Connect to a grounded socket only.
- If necessary, use an earthed extension cable of a suitable diameter.
- Fully extend the power cord and make sure the power cord does not contact the product.
- When using an extension cord, use one which is as short as possible and fully extended.
- Do not use external timers or remote control systems to switch the product on or off.
- Ensure people do not trip over the cord.
- Make sure that the power cable cannot become entangled and does not hang over the edge of a worktop.
- Do not leave the product unattended when switched on.
- R290 is a refrigerant gas that complies with the European directives on the environment.
- Be aware that refrigerants can be odorless.
- Place the product in an area without any continuous sources of ignition (for example: open flames, gas or electrical appliances in operation).
- Only install, operate and store the product in a room with a floor area above 11 m2.
- Only store the product in a well-ventilated area.
- Store the product in such a way as to prevent mechanical failure.
- When the product is installed, operated or stored in a non-ventilated area, make sure the room is designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
- Only persons with a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification, can work on or break into a refrigerant circuit.
- Servicing can only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel can only be carried out under the supervision of the person competent in the use of flammable refrigerants.
- When defrosting and cleaning the product, do not use any means other than those recommended by the manufacturing company.
- Do not puncture or heat any part of the refrigerant circuit.
- This product may only be serviced by a qualified technician for maintenance to reduce the risk of electric shock.
Explanation of the safety symbols on the product
Icon
|
Description
---|---
|
Indication to explain that the product:
Contains one or more (extremely/highly) flammable components.
Installation
Check the contents of the package
Check that all parts are present and that no damage is visible on the parts. If parts are missing or damaged, contact the Nedis B.V. service desk via the website: www.nedis.com.
Installing the product
- Place the product on a stable and flat surface.
- Leave a minimum of 0.5 m space around the air inlet and outlet to allow a good circulation of airflow.
- Only move the product in an upright position.
- If the product has been tilted, allow it to stand upright for 2 hours before plugging it in.
Assembling the exhaust (image B )
|
---|---
B
- Only use the provided exhaust hose.
- Do not block the exhaust hose, this may cause overheating.
-
Assemble the window kit A11 with the fasteners A15.
-
Install A11 in the window opening.
-
Tighten A15.
-
Assemble the exhaust hose A8, the exhaust nozzle A9 and the exhaust hose connector A10.
-
Connect A10 the air outlet A3.
-
xtend A8 up to 1500 mm.
– Do not twist the exhaust hose.
– Ensure that the exhaust hose does not kink. -
Snap A9 into A11 and fasten with the exhaust nozzle screw A16.
Place the product on a flat and dry surface.
Assembling the continuous drainage (optional)
1. Open the continuous drainage outlet A2.
2. Connect A2 to a water container or drainage system (not included).
Use
Using the control panel (image C )
C
C7
|
Switch the product on or off.
---|---
C6
|
Switch between cooling, dehumidifying and fan mode.
C2
|
Switch between high, middle and low fan speed. In dehumidifying mode, pressing C2 switches the fan to low speed.
C1
|
Press C1 and use C3 and C5 to set the duration of cooling.
The timer can be set to a maximum of 24 hours.
C4
|
Display
C8
|
Indicates that cooling mode is active.
C9
|
Indicates that dehumidifying mode is active.
C10
|
Indicates that fan mode is active.
C11
|
Indicates that the water reservoir needs drainage.
C12
|
Indicates that the temperature is set in Celsius (°C).
C13
|
Indicates that the temperature is set in Fahrenheit (°F).
C14
|
Indicates that timer mode is active.
C15
|
Indicates that the product is in sleep mode.
This function is only available in cooling mode.
C16
|
Blinks to indicate that the product has been reset.
C2,3
|
Press C2 and C3 simultaneously in cooling mode to switch to sleep mode.
After one hour the set temperature increases 1 °C and again after 2 hours.
C3,5
|
Press C3 and C5 in cooling mode to set the desired temperature. Press C3 and C5 simultaneously to switch between Celsius (°C) and Fahrenheit (°F).
Using the remote control (image D )
D
D1
|
Display
---|---
D2
|
Switch the product on or off.
D3
|
Activate timer mode.
D4
|
Activate oscillation.
D5
|
Activate sleep mode. Only works in cooling mode. After one hour the set temperature increases 1 °C and again after 2 hours.
D6
|
Increase and decrease values.
D7
|
Switch operating mode.
D8
|
Switch fan speed.
D9
|
Switch between Celsius and Fahrenheit.
Manual drainage
- C11 flashes and the product emits an alarm sound to indicate that the water reservoir is full.
- Switch off the product using C7
- Unplug A7.
- Place a water container underneath A6.
- Unscrew the manual drainage cap.
- Remove the water plug.
- Slightly tilt the product backwards to ensure all water leaves the reservoir.
- Put back the plug and screw the drainage cap back on.
Maintenance
E
Clean the product regularly as follows:
- Switch off and unplug the product when not in use or before maintenance.
- Remove E3 by pulling the handle.
- Unscrew the EVA-filter screen E2.
- Clean E2 in warm water (about 40 °C) with a neutral detergent.
- Rinse and dry E2 in the shade.
- Put back E2 and the screws E1.
- Clean the filter screen E4 once every 2 weeks.
- Clean the outside of the product with a soft, clean, lightly damp cloth.
- Avoid abrasives that can damage the surface.
- Do not use aggressive chemical cleaning agents such as ammonia, acid, acetone or gasoline when cleaning the product.
Store the product as follows:
- Drain the product.
- Use C2 to switch on the product.
- Press C7 to switch to low fan speed operation.
- Wait until A6 is dry.
- Put back the plug and screw the drainage cap back on.
- Switch off the product.
- Unplug the product.
- Remove the batteries from At during long periods of disuse to avoid possible leakage.
- Store the product in a dry place away from sunlight and protect it against excessive dust and dirt.
Warranty
Any changes and/or modifications to the product will void the warranty. We accept no liability for damage caused by improper use of the product.
This product is designed for private use (normal domestic use) only. Nedis is not responsible for wear, defect and/or damages caused by commercial use of the product.
Disclaimer
Designs and specifications are subject to change without notice. All logos, brands and product names are trademarks or registered trademarks of their respective owners and are hereby recognized as such.
Disposal
|
This symbol indicates that this product should not be thrown away with other household waste throughout the EU. To prevent possible harm to the environment or human health by uncontrolled waste disposal, you are responsible for recycling it so that it can promote the sustainable reuse of raw materials. To return your used product, you can use the regular return and collection systems or contact the store where the product was purchased. They can recycle this product for the environment.
---|---
Read User Manual Online (PDF format)