SATCO S9932 15T8U6/LED/22.5-840/BP LED T8 U Bend Bulb Instruction Manual

June 5, 2024
SATCO

SATCO S9932 15T8U6/LED/22.5-840/BP LED T8 U Bend

BulbSATCO-S9932-15T8U6-LED-22-5-840-BP-LED-T-U-Bend-Bulb-
PRODUCT

Product Features

  • c-UL-us Classified and Recognized
  • Full glass housing: No Aging, Yellowing, Bending

Product Applications

Widely used in residential buldings, offices, shopping malls, supermarkets, hospitals, assembly lines, warehouses, etc. for energy-saving illumination.

Installation Instructions

Please completely comply with these instructions and notes, to ensure that the product is operated in a safe condition.

Safety Precautions

For your and others’ safety. please read the precaution carefully before installation:

  1. Product should be installed by qualified electrician.
  2. Switch off the power supply before commencing work, make sure correct connection before power on.
  3. Do not apply uncertified LED driver with the product.
  4. NOT FOR EMERGENCY LIGHTING.
  5. Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control. Only operate with specific dimmer MEX G1 NA 45W manufactured by Jiaxing Super lighting

Operation Instruction

By Pass/Line Voltage

  • Product Name: LED T8U-Bend
  • Input Voltage: AC 120-277V
  • Product Model:15T8U6/LED/22.5-8XX/BP
  • Product Models Included:
    S9930 15T8U6/LED/22.5-830/BP
    s9931 15T8U6/LED/22.5-835/BP
    s9932 15T8U6/LED/22.5-840/BP
    s9933 15T8U6/LED/22.5-850/BP

Wiring Instruction

SATCO-S9932-15T8U6-LED-22-5-840-BP-LED-T-U-Bend-Bulb-
FIG-1

WARNINGS

  • Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
  • To avoid potential fire or shock hazards, do not use this retrofit kit in luminaires employing shunted bi-pin lamp holders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself or may be combined with the marking for the lamps with which the ballast is intended to be used, for example, F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.
  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead, installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
  • Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for the installation of an LED retrofit kit. Check for enclosed wiring and components.
  • THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE cOMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
  • Type B LAMP – intended for operation in luminaires with traditional fluorescent-type lamp holders wired directly to the branch circuit. This includes both factory-wired luminaries as well as those converted for this purpose under a retrofit program.