Safety Precautions

  • Please read all instructions carefully for safe and proper use.
  • Use only as directed.
  • Immediately discontinue use if any malfunction or unusual reaction to treatment occurs.
  • Precautions listed in the instruction manual are very important. For your safety, please follow them carefully.
  •  Precautions are classified as DANGER, WARNING, or CAUTION in order to clearly specify the level of danger and possible injury or damage that may occur if the device is misused.

DANGER| Improper use of this device poses a severe and likely risk of death or serious injury.
---|---
WARNING| Improper use of this device may pose a risk of death or serious injury.
CAUTION| Improper use of this device may result in fire, injury, or property damage .

YAMAN-HRF-10-Portable-RF-Beauty-Instrument-fig1

DANGER

  • Do not use under any of the following conditions as this may cause malfunction of medical devices.
  • Do not use in conjunction with any medical electronic equipment such as a pacemaker, oxygenator, electrocardiograph, etc.

WARNING

To avoid accident or injury to your skin or body, do not use under the following conditions:

  • While pregnant or nursing or during menstruation
  •  While growing or during adolescence
  •  If you suffer from atopic dermatitis or have unusually sensitive skin
  •  If you have skin allergies or bleeding diathesis
  •  If you have skin irritation or redness caused by sunburn
  •  There is suppuration or inflammation of the skin
  • You experience skin irritation caused by cosmetics
  •  Have itchy pigmentation or pathologic pigmentation
  •  Have viral warts or melanoderma
  •  Have abnormal blood pressure
  •  Have weak skin sensibility
  •  If you are sick or feeling unwell
  •  If you have capillary dilatation due to long term use of steroid hormonal drugs or a disorder of liver function
  •  If you are under a doctor’s care

Do not use if you suffer from any of the following conditions, or on body areas listed below as this may cause injury:

  • Acute disorder, febrile disorder, contagion, fissures, feeling unwell, extremely exhausted, tuberculosis, abnormal blood pressure, malignancy, heart disease, or if you have consumed alcohol or medication that causes drowsiness.
  • Do not use inside the mouth or around the pubic area, mucous membranes, on eyelids or eyeballs, or around the eyes (except in COOL mode). Do not use over broken bones, over the Adam’s apple or acne, or on areas where you have had plastic surgery.
  • If you are not sure, consult your doctor before use.
  •  RF LED Mode can be used over eyelids and around the eyes; Close your eyes and hold the machine 5cm away from the eyes.

Do not apply over the same area continuously. Always move the device over the skin while treating to avoid possible skin burns.
Do not place the device near fire or flame, or dispose of in a fire.
Do not use, charge, or store in a high temperature area or if the device is hot.

WARNING

  • Do not use near flammable substances such as thinner, benzene, nail polish remover, or hair spray as this may cause fire, electri cal shock hazard, or injury.
  • Use only with the supplied AC adapter. When using the AC adapter, plug it di rectly into the wall socket. Do not use an extension cord as this may cause an electrical shock hazard, short circuit, or fire.
  • Do not use on children or allow children to use the device. Keep out of reach of children . Do not allow disabled persons to use the device unattended.
  • Avoid use on persons with sensitive skin or on those who cannot express their intentions as this may cause injury.
  • If any problem occurs during use, including abnormal odor, smoke, or excess heat, turn off the power and unplug the AC ad apter immedi ately. Discontinue use if there is smoke or an unusual noise or odor.
  • Use only as directed in this instruction manual. Improper use may cause injury or malfunction.
  • Do not damage, break, modify, bend by force, pull, twist, or bundle the cord. Do not place heavy objects on the cord or allow it to get pinched in between other objects as this may damage the cord and cause a fire or electrical shock hazard.
  • Do not use if the AC adapter is damaged or the wall socket is loose. This may cause an electrical shock hazard, short circuit, or fire.
  • Do not allow the main unit, AC adapter, or cord to get w e t
  • Avoid use near water as this may cause an electrical shock hazard, short circuit, or fire.
  • Do not disassemble, attempt to repair, or modify this device in any way as this may cause a fire, electrical shock hazard, or injury.
  • Consult your local agent if repair is needed.
  • Warranty applies only to use within country of purchase. Warranty repair for foreign customers is not available.
  • Before charging the unit, check that the plug and socket are not wet as this may cause an electrical shock, short circuit, or fire hazard.
  • Be sure to turn off the power when not in use or when cleaning the unit to avoid a potential electric shock, short circuit, or fire hazard.
  • Discontinue use if there is an unusual odor or if the device overheats to avoid potential damage or fire.
  • Unplug AC adapter from the wall socket when not in use. Do not handle with wet hands as this may cause an electrical shock, short circuit, or fire hazard.
  • To avoid accident, injury, or malfunction:
    •  Do not use if you have any unusual skin condition such as a rash, irritation or itching.
    •  Do not use if the device is damaged, has been dropped, or subjected to impact.
    •  Do not use this device for professional treatments and avoid continuous or excessive use.
  • Use only AC100-240V to avoid a potential fire or electrical shock hazard.
  • Hold the head of the plug instead of the cord when unplugging the adapter from the wall socket.
  • Damage to the cord may cause an electrical shock, short circuit, or fire hazard.
  • Do not use or store near fire, under direct sunlight, or in humid places such as the bathroom.
  • Do not place near heating equipment as this may cause a fire or explosion hazard.
  • Choose a lower Intensity Level to allow your skin to accommodate to the stimulation if you have teeth fillings or are having any dental treatment.

CAUTION

  • Do not look directly at the LED light.
    •  RF LED Mode can be used over eyelids and around the eyes; Close your eyes and hold the machine 5cm away from your eyes.
  • Do not use Cool Mode successively:
    •  If used for successive treatments, the head will not fully cool.
    •  Allow at least a 30 minutes interval before next use.
  • Do not wipe the main unit with alcohol, thinner, benzene, nail polish remover, or any solvents which could damage the device.
  • Do not put the electrode head in contact with metals. This may cause a malfunction or injury.
  • Do not apply to pets or animals as this may cause injury.
  • Do not place or use on an unstable surface. Avoid dropping or subjecting the device to impact as this may cause injury or malfunction.
  • Follow the precautions below to avoid accidents, injury, or malfunction:
    •  Do not apply over the same area continuously. Always move the device over the skin while treating.
    •  Apply treatment according to your particular skin type and condition.
    •  Avoid use if you are sunburned or in conjunction with peeling, face mask, or mud mask treatments.
    •  Always turn off the power after use.
  • Always begin treatment with the intensity set at Level 1 to allow your skin to accommodate to the stimulation.
    • Starting at too high an intensity level may cause injury.
  • Discontinue use if you feel discomfort to your face or body during use. If you see an abnormal skin reaction during or after use, stop using and consult a doctor.
  • Use at AC100-240V only to avoid a potential fire or electrical shock hazard.
  • Be sure to check the plug shape and the voltage before using. Using this device with an improper plug or at the incorrect voltage may cause overheating, fire, or malfunction.

NOTE: This product can be operated with 100-240V. If the plug of the supplied AC adapter does not match the plug of your location, use a plug adapter (not provided).

  • The plug configuration and voltage varies depending on the region and the type of accommodation. Always be sure to check for compatibility before using the device.
  • For information about plug adapters, consult a travel agency or a consumer electronics retailer.

Features

This product is a home use beauty device that integrates RF (radio frequency) deep warming with Ion Cleansing / lontophoresis, Vibration, LED Photo, and EMS technology. It can be used to suit your personal skin condition and to achieve your objective by combining the following available treatment modes:

  • RF
    RF warms up deep tissue* to prepare the skin and enhance the benefit of the treatment that follows. Unlike typical heaters, this mode can instantly heat deep inside the skin tissue.

  • Ion Cleansing
    Ion treatment helps to thoroughly cleanse the skin by attracting stubborn dirt and oil that cannot be removed by normal cleansing.

  • Ion Moisture
    Moisturizes the skin by improving the penetration of skincare products deep into the skin*.

  • EMS
    Stimulates the muscles using gentle electrical current.

  • Vibration
    Treats your skin with gentle vibration.

  • LED Photo
    Treats your skin with LED Photo (light) therapy.

  • Cooling
    Helps tighten your skin with cooling action

Product Description

YAMAN-HRF-10-Portable-RF-Beauty-Instrument-
fig2

Cotton Stopper (Silver Ring)

  • Cotton Stopper is attached to electrode head when purchased.
  • Use this Stopper to apply cotton to the head.

AC Adapter

  • Design and specifications of the main unit and accessories are subject to change for improvements without prior notice.

Before Use

Indicator Panel
  • Panel / Buttons
  • Press and hold the POWER/MODE button to turn the power on.The treatment will automatically start with RF Cleansing mode.
  • Treatment mode can be changed by pressing the POWER/MODE button any time during operation.
  • Level can be selected when using RF Cleansing, RF Moisture, and RF EMS UP modes. Each mode has 5 intensity levels adjusted with the LEVEL button.
  • Press and hold the POWER/MODE button to turn the power off
  • RF thermal temperature cannot be changed.

MODE Indicator
Each time you press the POWER/MODE button, the treatment mode will be selected in this order: RF Cleansing – RF Moisture – RF EMS UP -RF LED -+ COOL -+ RF Cleansing (repeat).YAMAN-HRF-10-Portable-RF-Beauty-Instrument-
fig6

The RF symbol RF alternates during RF Cleansing, RF Moisture, and RF EMS modes. RF is applied when you hear a short beep sound and the RF symbol RF appears. When you hear two short beeps, Ion or EMS modes are applied and RF symbol (§ does not appear.

LEVEL Indicator

In RF Cleansing mode or RF Moisture mode, the intensity level of ion treatment can be adjusted by pressing the Level button. In RF EMS UP mode, the intensity level of EMS can be adjusted by the Level button.
There are 5 levels of treatment. Choose a level that you find comfortable.
Each time the Level button is pressed, the level will change in this order:
Level 1 – Level 2 – Level 3 – Level 4 – Level 5 – Level 1 (repeat).

  • Thermal temperature of RF is fixed and cannot be changed.
  • Always start from Level 1 if it’s your first treatment or until you become accustomed to the operation and treatment. YAMAN-HRF-10-Portable-RF-Beauty-Instrument-fig8

Charging Indicator The Charging indicator will appear on the indicator panel and will flash while the unit is charging. When charging has completed, the charging indicator will turn solid.

  • Charging indicator will not appear during use.

Standby / Auto-off (Automatic Power Off)

2 minutes after finishing the RF Cleansing, RF Moisture mode, RF EMS UP, or RF LED mode, the next mode will flash on the panel and the POWER/MODE button will flash, indicating that the unit is in standby (not treating).
Press the POWER/MODE button to start the next mode which is waiting in standby.
The power will turn off automatically after 2 minutes in standby.
Power will turn off automatically immediately after Cool mode is complete.

Charging the Battery

The product is rechargeable and can be used without being connected to the AC adapter. Be sure to use the device after charging.
Before using for the first time, or if you have not used the device for an !JXtended period, fully charge the battery and make sure that the Charge Indicator has turned from flashing to solid, indicating a full charge.

Charging Time

Charge Time Operating Time
2.5 Hours 40 Minutes
  •  Ambient temperature of 25°C.
  •  Operating time is how long it can be used immediately after a full charge.
  •  Operating time may differ depending on the operation mode, intensity level, and environment.
  •  Charging time may differ depending on the remaining battery and environment.

How to Charge

  1. insert the AC adapter plug into the adapter socket of the main unit.
  2.  Plug the AC adapter into the wall socket.
    •  Use only with the supplied AC adapter.
    •  When using the AC adapter, plug it directly into the wall socket. Do not use an extension cord.
    •  When charging had started, the Charge Indicator will flash. When charging is complete, the Charge Indicator will turn solid.
  3. When charging is complete, unplug the AC adapter from the  wall socket and then remove the adapter plug from the main unit.

About the Treatment Modes

__

Mode

| RF Cleansing [CLEAN]| RF Moisture [MOISTURE]| RF EMS UP [EMS UP]| RF LED [RF LED]| Cool [COOL]
---|---|---|---|---|---
__

__

__

__

__

__

Features

| Warms up the tissue from inside. Ion cleanses skin by attracting stubborn dirt and oil that can’t be removed with normal cleansing.| Warms up the tissue from inside. Ion moisture helps deliver skincare ingredients deep into skin* and also moisturizes.

*** T o s tr a tum**

| Warms up the tissue from inside.

EMS

stimulates the muscles for firmed skin.

*Can also be used on neck and

shoulders.

| Warms up the tissue from inside and applies LED Photo treatment at the same time.| Improves skin elasticity and skin texture

with cooling treatment.

 |  | co rn e um|  |  |
__

Function

| RF

Ion Cleansing Vibration

| RF

Ion Moisture Vibration

| RF EMS| __

RF LED

| __

Cooling

Uses Cotton| YES| YES| NO| YES| NO| NO
Skincare Product| __

Thick Lotion

| Thick Lotion| Facial Mask| Thick Lotion or Gel| Thick Lotion or Gel|
Time| 3 minutes| 3 minutes| 3 minutes| 3 minutes| 3 minutes
Level| Ion: 5 levels| Ion: 5 levels| EMS: 5 levels| N/A| N/A
Frequency| 2 – 3 times a week| Daily

Always move the treatment head over the skin while treating, except when using the COOL mode.

  1. Only use water soluble skincare products. Oils, scrubs, creams, and emulsions cannot be used.
  2. The device may get hot after using the COOL mode. Do not apply successively in this mode. Allow the device to rest (with power off) at least half an hour after use.
  3.  RF Moisture mode helps deliver skincare ingredients to the stratum corneum.

Treatment

Attaching Cotton to the Head
  1. Remove the cotton stopper from the treatment
  2. Mount circular the treatment cotton head. on head top of and the press the cotton stopper down over the cotton.
    • Do not use cotton in layers.
    • If the cotton stopper does not fit properly on the treatment head, use thinner cotton.
    • If the cotton is too thick, the thermal action of RF treatment may be adversely affected and you will feel less heat.
  3. Soak your preferred moisturizing lotion or gel into the cotton attached to the treatment head.
    • Make sure that the lotion or gel coats the entire surface of the treatment head.
    • If you use thin lotions, the thermal action (heating) of RF treatment may be reduced. Recommended thick lotion: Only Minerals Extra Serum (OM14021 Ask your local distributor for details).
    • This device is not water-proof so be sure to thoroughly wipe off any lotion or gel left on the device with a dry cloth after each use. Do not wash with water or other liquids.
How to Use (General Instructions)
  • Precautions when using
  • Always move the device over the skin during use. Do not hold on a fixed area as this may cause burns.
  • The temperature of RF may feel different depending upon the condition of your skin.
  • Do not use on eyelids or around the eyes except in COOL mode or in RF LED mode as specified below.
  • RF LED mode can be used on eyelids and around the eyes; Close your eyes and hold the machine 5cm from your eyes.
  • Never look directly at the LED light.
  • Always hold the device so that you are touching the hand electrode on the rear of the device.
  • Recommended ambient temperature is 15°C ~ 30°C.

How to Apply Treatment

  1. Remove makeup and gently cleanse your face.

    • Remove oil and dirt from your skin so that it is in a clean condition prior to treatment.
    • COOL mode can be used over makeup
  2. Attach cotton if necessary and apply lotion onto the cotton.

  3. Press and hold the POWER/ MODE button to turn power on.

    • Choose a treatment by pressing the POWER/ MODE button again.

    • Choose an intensity level by pressing the LEVEL button.
      NOTE: RF thermal temperature is fixed and cannot be changed.

    • Always start from Level 1 if it’s your first treatment or until you become accustomed to the operation and treatment.

  4. Hold the device so that you are touching the hand electrode on the rear of the device

  5. Gently apply the treatment head to your skin and move the head over the area being treated. (Refer to p.15-16 for more details)

    • When the mode is finished, the device will go into standby for 2 min. After using the COOL mode, the device will automatically turn off.
    • Press POWER/ MODE button to start the next mode or press and hold POWER/ MODE to turn off the power.
  6. After treatment, condition your skin as necessary.

    • Condition your skin using lotion, facial mask, skin milk, skin cream, etc.
  7. the residue of skincare lotion or gel remaining on the electrode head or cotton stopper.

    • This device is not water-proof so be sure to thoroughly wipe off any lotion or gel left on the device with a dry cloth after each use. Do not ash with water or other liquids.

How to Apply Treatment

  • Recommended speed for moving the head over skin: 2cm per second.
  • If the temperature feels too hot, move the head more quickly.
  • Make sure the entire surface of the treatment head touches the skin during use.
  • Always move the device over the skin during use. Do not hold on a fixed area as this may cause burns.
  • Do not place the treatment head in contact with eyelids or eye area.

[RF Cleansing / RF Moisture / RF LED Mode ]
Move treatment head over the skin in the direction of arrows shown below.

  • RF LED mode can be applied over eyelids and around the eyes.
  • Close your eyes and hold the electrode head 5cm away from your eyes.

YAMAN-HRF-10-Portable-RF-Beauty-Instrument-fig10

[RF EMS UP Mode ]
Move treatment head over the skin in the direction of arrows shown below. YAMAN-HRF-10-Portable-RF-Beauty-Instrument-fig11

  • Make sure the entire surface of the treatment head touches the skin during use.
  • Always move the device over the skin during use. Do not hold on a fixed area as this may cause burns.
  • Do not use on eyelids or around the eyes.

After Treatment

Clean the device after each use for sanitary reasons.

Care and Storage after Use

  1. nsure the power is off and unplug the AC adapter from the  main unit.
  2. Wipe any dirt off the surface of the treatment head or on the cotton stopper with a well wrung towel.
    • Remove the cotton stopper from the head when cleaning.
    • Never use detergents, alcohol, or solvents such as thinner.
    • Do not store or leave the device with lotion or gel adhering to themain unit.
  3. Wipe off any dirt from areas other than the head and cotton stopper with a dry cloth.
  4. Allow the unit to dry in a well-ventilated place and then4 Allow the unit to dry in a well-ventilated place and then store.
    • When not using the device, turn off the power, unplug the AC adapter from the main unit and the wall socket, and store in a clean, dry place.
    • Never place the unit near fire or flame, under direct sunlight, or in humid areas such as the bathroom. Store only in a clean, well-ventilated place.
    • Store the unit out of the reach of children.

After Service

About the rechargeable battery

  • The rechargeable battery is a consumable item (not covered under warranty).
  • If the battery only powers the device for an extremely short period after charging, it may be at the end of its useful life. With typical use, the battery can be charged approximately 300 times.
  • If you need a battery replacement, contact your local distributor. The battery is not user-replaceable.

About Disposal

  • Follow your local government rules for proper disposal of this product.
  • This product uses a lithium ion battery.

Troubleshooting

Checklist for Possible ProblemsYAMAN-HRF-10-Portable-RF-Beauty-
Instrument-fig12 YAMAN-HRF-10-Portable-RF-Beauty-
Instrument-fig13 YAMAN-HRF-10-Portable-RF-Beauty-
Instrument-fig14**FAQ (Frequently Asked Questions)**

Q A

How much lotion or gel should I use for each treatment?

| This device is designed to achieve better effects with sufficient use of lotions and/or gel. Apply lotion or gel on cotton so that the whole surface of the electrode head is wet. Add more when you feel it is not enough.

Can I use this device in the bathroom?

| This product is not waterproof. You should not use it in the bathroom or in humid areas where it may get wet.

Why does my skin blush after use?

| This is due to using RF for deep heating. If it bothers you, use the COOL mode or apply blue ice to cool down your skin.

Why do I feel a tingly sensation on my face and hands?

| This is electrical stimulation from Ion Cleansing, Ion Moisture, or EMS and is normal.

You can adjust to a comfortable intensity level using the LEVEL button.

Always start at Level 1 for your first treatment or until you get used to the operation or treatment.

Why do I not feel warmth when  using RF cleansing, RF moisture, RF EMS UP, or RF LED mode?

| Move the treatment head more slowly or press harder against the skin surface.

It’s also possible that the cotton is too dry, so you can add more lotion or gel to moisten the cotton. RF repeats, turning on and off during treatment.

When the RF symbol I§ appears, RF is on.

Why can’t I see dirt on the cotton?

| Dirt is removed even though it may not be visible on the cotton. The amount of visible dirt on the cotton can vary between individuals.
Why does the head not get warm in RF?| RF is designed to electrically warm the skin tissue, not the treatment head itself.