YAMAN SEYE 1 Home Beauty Device Bloom EYE User Manual

June 5, 2024
YAMAN

YAMAN SEYE 1 Home Beauty Device Bloom EYE

YAMAN-SEYE-Home-Beauty-
Device-Bloom-EYE-PRODUCTIntroduction

Thank you for purchasing the YA-MAN product.

  • Please read this User’s Manual carefully for information on how to use the device properly and safely.
  • After reading the contents hereof, be sure to keep this User’s Manual in an accessible location.
  • Make sure to include this User’s Manual if you are transferring ownership of the device to another person.

Safety Precautions

  • Read these Safety Precautions carefully before using the device in order to use it correctly.
  • Use the device sensibly in accordance with the prescribed steps.
  • Immediately discontinue use and arrange to have the device repaired if any abnormality occurs.
  • Do not use the device in a defective state, as doing so could cause physical harm to the user.
  • The precautions listed in the User’s Manual are very important. For your safety, please follow them carefully.
  • Precautions are classified as DANGER, WARNING, or ATTENTION in order to clearly specify the level of danger and possible injury or damage that may occur if the device is misused.

Classifications of Precautions

Improper use of this device poses a severe and likely risk of death or serious injury.
Improper use of this device may pose a risk of death or serious injury.
Improper use of this device may result in injury or property damage*.

  • ‘Property damage’ refers to damage affecting a dwelling, household belongings, or domestic animals and pets.

Symbols (the following are examples of the symbols

  • This symbol shows you what you must not do.
  • This symbol shows you what you must do.
  • This symbol shows you what you must be careful with.
DANGER (regarding use and storage)
  • The following individuals should not use the device.
    The use of the device could cause electronic medical devices to malfunction.

  • Do not use in conjunction with any medical electronic equipment, including:
    pacemakers or other implanted electronic medical devices; artificial heart-lung machines or other electronic life-support medical devices, and electrocardiographs or other worn electronic medical devices.

WARNING (Use and storage)
  • Do not use it under the following conditions:
    Failure to comply may cause an accident or other problems.

    • If you are under a doctor’s care • If you are a child or adolescent • If you have an acute disease • If you have tuberculosis • If you have a fever
    • If you are suffering from hypertension • If you have an infectious disease • If you have a malignant tumor • If you have a blood disease • If you have a visceral disease
    • If you have a skin disease • If you have an allergic constitution • If you have atopic dermatitis • If you have skin problems • If you have sensitive skin
    • If you have unhealthy skin blemishes caused by physical irritation • If you are experiencing skin irritation or redness due to sunburn • If you are severely fatigued
    • If you are physically unwell • If you are under the influence of alcohol • If you are pregnant, menstruating, or lactating • If you take medication that induces drowsiness
    • If you have capillary dilatation due to long-term use of steroid hormonal drugs or a liver disorder; • If you have excessive myopia (-6D or higher)
    • If you have had an eye or face operation • If you have diseases of the eyes or face or you are under treatment;
  • Do not use the device on the areas indicated below or outside of specified areas.
    Failure to comply may cause an accident or other problems.

    • Cuts • Sites where plastic surgery was performed • Sites where cosmetic surgery was performed
    • Anywhere inside the mouth, around the pubic region, or any mucous membrane • Acne • Sites where skin suffers from purulent inflammation
    • Sites with itchiness or a hot sensation • Bulging moles • Viral warts • The Adam’s apple • Above implants • Eyeballs • Eyelids, eye sockets
  • If you are uncertain as to whether it is safe to use the device, consult a physician prior to use.

    • Do not use it continuously in the same area. Be sure to move the device across the skin while it is in use. Do not use on areas that cannot be reached by the entire electrode head surface.
      Failure to comply may cause burn injuries.

    • Do not overuse the device. For usage time and frequency, follow the instructions in the User’s Manual.
      Failure to comply may cause physical injury.

    • Do not use the device continuously for an overly long period (for example, through commercial use).
      Failure to comply may cause an accident, a failure of the device, or an injury.

    • Do not use the device for a long time over sites where the skin is thin or sites above bones.
      Failure to comply may cause skin problems or physical ailments.

    • Do not use the device near a flammable substance (such as alcohol, thinner, benzene, nail polish remover, or spray). Doing so may cause the device to explode or catch fire.

    • Do not use the device in the bathroom or near a bathtub, shower, sink, or other vessels filled with water.
      Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.

    • Do not splash water on the device (main body, etc.) or immerse it in water. Do not use the device in a high-humidity location or where it may be splashed with water
      Failure to comply may lead to a fire, electric shock, or malfunction.

    • Do not use the device for any purpose other than those stated in the User’s Manual.
      Failure to comply may cause a failure of the device or an injury.

    • Use by unattended children or individuals with physical disabilities should be avoided. Minors should use the device only under the supervision of a guardian who has given their consent.
      Failure to comply may cause an accident or an injury.

    • Do not use the device on individuals who are unable to express their will or who have reduced skin sensitivity. Failure to comply may cause an accident or an injury.

    • Keep the device and generic AC adapter away from children and do not allow them to use either. Do not allow children to play with the device.
      Failure to comply may cause an accident or an injury.

    • Do not place the device in an unstable location. Do not drop or bump the device (either the main body or attachments).
      Failure to comply may cause a failure of the device. An injury may also be caused if the device is dropped on a foot or other exposed body part.

    • Do not place heavy items on the device, drop the device (especially during use), or otherwise subject the device to a strong impact.
      Failure to comply may cause an injury or a failure of the device.

    • Do not disassemble, attempt to repair, or modify this device in any way.
      Failure to comply may cause a fire, electric shock or other injuries. Contact your local distributor for advice on repairing the device.

    • If any problem occurs during use, including the presence of an abnormal odor or excess heat, stop using the device. Failure to comply may cause the device to become damaged or catch fire.

    • Do not leave the device in hot or humid places, such as near flames, in bright sunlight, or in a bathroom. Do not bring the device close to a heater.
      Failure to comply may lead to the generation of heat, a fire, or an explosion.

    • Do not place the device near fire or flames, and do not dispose of the device in a fire. Do not use, charge, or store in a high-temperature area or if the device is hot. The device features a built-in rechargeable battery.
      Failure to comply may lead to the generation of heat, a fire, or an explosion.

    • Be sure to check the plug configuration and the voltage of the power outlet before use.
      Failure to comply may cause the generation of heat, a fire, or a malfunction of the device.

    • Do not put the device into a microwave or pressure vessel. Failure to comply may lead to the generation of heat, a fire, or explosion.

    • If water or foreign matter gets into the device, immediately stop using it and request an inspection.
      Failure to comply may lead to a fire or electric shock.

    • If you are currently undergoing dental treatment or have teeth fillings, choose a lower intensity level and apply the device on a different area.
      You may feel strong irritation or discomfort by EMS on your cheeks or chin. If you feel strong discomfort, consult a physician.

    • If you sense an earthquake or see lightning, turn the power off or disconnect the AC adapter while the device is charging.
      Failure to comply may lead to a fire or electric shock.

    • Do not use or store the device in the following locations:
      Failure to comply may lead to a fire, electric shock, malfunction, failure of the device, or other accidents.

      • A high-humidity location such as a bathroom
      • Dusty areas
      • A location where there is exposure to direct sunlight
      • A location where water or other liquids may splash on the device
      • A tilted location, or a location where there is vibration or shocks
      • An outdoor location
      • A location where there are strong radio waves or magnetism
      • Locations that are accessible to children
      • A location where there is exposure to oil smoke or steam
      • A location that may become hot, such as near a heating device (for example, a heater)
      • A location with drastic temperature changes (for example, near an air conditioner or heater)
    • If the device is dropped or damaged, turn off the power immediately and request a repair/inspection.ailure to comply may lead to a fire or electric shock.

    • Do not leave the device unattended while it is turned on.
      Doing so may cause the device to catch fire or may lead to an accident.

ATTENTION (Use and storage)
  • Before use, check to make sure the electrode head is not cracked, deformed, or broken. Do not use the device if it is damaged or malfunctioning.
    Failure to comply may cause your skin to suffer an injury or other problems, or lead to the worsening of existing conditions.

  • Do not use continuously on the same area for more than five minutes.
    Failure to comply may cause skin problems.

  • Do not press the device strongly or use it intensively on a single spot.
    Pressing the device stronger than necessary or using it intensively on a single spot may damage the skin.

  • Do not allow the device to come into contact with another beauty device or electronic appliance while the power is on. Do not use with other electronic products (electric blankets/bed sheets, heated tables, etc.) at the same time.
    Failure to comply may lead to an accident due to malfunction.

  • Do not wipe the device with solvents such as alcohol, thinner, benzene, nail polish remover, kerosene, chemicals, or polishing powder.
    Failure to comply may cause damage to the surface of the device.

  • Avoid allowing the electrode head to come into contact with any other metal surfaces.
    Failure to comply may cause a failure of the device or an injury.

  • Do not use the device on pets.
    Failure to comply may cause injuries.

  • Do not use the device above clothes.

  • Do not use the device outdoors.
    Failure to comply may cause a failure of the device.

  • Be sure to remove makeup before using the device on your face.
    If you use the device over makeup, the foundation may cause dark staining of the skin.

  • Be sure to comply with the following items.
    Failure to comply may cause an accident, injury, or failure of the device.

    • Use the device appropriately based on your skin condition.
    • Do not use the device after sunbathing, or in combination with peelings, skin packs, or other treatments.
    • Be sure to turn the device off after use.
  • During treatment, carefully check that your skin is not showing any abnormalities.
    Discontinue use immediately if you start to feel pain or fatigue or if you see any skin reaction during use.
    Stop using the device immediately if the treatment does not agree with your skin. If symptoms persist the following day and beyond, consult a physician.

  • Use only Level 1 upon first use and until you are accustomed to use.
    Failure to comply may cause an accident or injury.

  • When you have not used the device for a long period of time, check to see that it is functioning normally before re-starting use.
    Failure to comply may lead to an accident or malfunctions.

  • Remove all metal accessories (watches, necklaces, rings, earrings, etc.) when using the device.
    Failure to comply may cause an accident or an injury. Accessories may also become entangled in the device.

  • Reapply skin-care products or water during treatment to ensure that there is always some liquid between the electrode head and the skin.
    If there is an insufficient amount of skin-care products or water, the stimulation will weaken, causing skin problems.

  • If you feel an unpleasant tingling on your skin, reduce the intensity level or move to another area. Alternatively, moisturize your skin with the included skin-care products before use.
    Failure to comply may cause skin damage.

  • When using on the same area again, be sure to leave an interval of 24 or more hours between treatments. Excessive use may damage the skin. The above recommendations are guidelines only; please observe your skin condition and use the device accordingly.

  • After each use, remove the dirt, cosmetics, and other particles that have adhered to the device according to ‘After Treatment.’
    Failure to comply may cause a failure of the device or skin problems.

  • When cleaning the device, be sure to turn off the power, disconnect the USB cable from the device, and follow the instructions in the User’s Manual.
    Failure to comply may lead to an accident or malfunctions.

WARNING (The power supply)
  • Use the USB cable included with this product.
    Plug the AC adapter directly into a wall power outlet and do not overload the electric circuit.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.

  • Do not damage, modify, bundle, or otherwise apply undue force to the USB cable.
    Failure to comply may cause the cable to break, resulting in a fire or electric shock.

  • Do not wrap the USB cable around the device when storing the device.
    Placing a load on the USB cable may cause a disconnection, resulting in electric shock, or a short circuit.

  • Do not use the device if the USB cable is damaged, or if the wall socket is loose.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.
    Contact your local distributor for advice on repairing the device.

  • Do not soak into, spill over or wash USB cable with water. Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.

  • When disconnecting the USB cable from the device or generic AC adapter, be sure to hold the cable at the front as you pull (do not touch the metal part).
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.

  • Unplug the USB cable when not in use.
    Do not insert or disconnect the plug with wet hands. Failure to comply may cause an electric shock, short circuit, or fire.

  • In the unlikely event that an abnormality occurs, immediately unplug the USB cable.
    Do not use the device if smoke, abnormal noises, or an odor is detected, or if it is otherwise operating in an abnormal state.

  • Before charging the device, check to ensure the charging terminal and USB cable are not wet. Failure to comply may cause an electric shock, short circuit, or fire.

  • Do not pull the USB cable when moving or lifting the device.
    Failure to comply may cause an electric shock, short circuit, fire, or failure of the device.

  • Be sure to use only with a 5 V USB power supply.
    Make sure that the USB cable is fully inserted into the USB port.
    Failure to comply may cause a fire, electric shock, or other accident.

When Using Outside of Japan

WARNING

  • Be sure to use only with a 5 V USB power supply.
    Failure to comply may cause a fire, electric shock, or a failure of the device.

  • Be sure to check the plug configuration and the voltage of the power outlet before use. Failure to comply may cause the generation of heat, a fire, or a malfunction of the device.

    • The plug configuration and voltage may vary depending on the region and the type of accommodation. Always be sure to check for compatibility before using the device.
    • For information about plug adapters, consult a travel agency or a consumer electronics retailer.

Names and Functions of Components

Main Body

Front view   RearYAMAN-SEYE-Home-Beauty-Device-Bloom-
EYE-4

Accessories

  • USB cable (USB Type-C™)
  • Flawless Serum Moisture 20G Flawless Serum Smooth 20G
  • User’s Manual
    The design and specifications of the device and attached accessories are subject to change for improvement purposes without notice.
    USB Type-C™ and USB-C™ are trademarks of the USB Implementers Forum.

Functions

Safety functions
  • Current sensor
    Measures the output current value and controls the output.

  • Temperature sensor
    The output will be reduced automatically for safety reasons when the temperature on the skin or the electrode head rises.
    If the temperature becomes too high, the power will be turned off for safety. (When this happens, the electrode head flashes and beeps five times)
    If this happens, let the device rest for about 30 minutes.

  • Motion sensor
    The motion sensor detects movement of the device and pauses output for safety reasons when the electrode head has been used on the same area continuously. When movement of the device slows, the motion sensor may reduce the level of warmth.

Auto Power Off / Standby

The treatment duration on the entire face is about five minutes. After approximately 2.5 minutes, a long beep will sound and the device will enter Standby mode.
Standby lasts for approximately 5 minutes and the Level lamp flashes (all outputs pause). Press the Power button ( ) to start the second half, which lasts approximately 2.5 minutes. The device will automatically switch off after the second half, which lasts approximately 2.5 minutes (two short beeps).
The device will automatically switch off (Auto-Off function) after being left in Standby mode for approximately five minutes without any operations (two short beeps).

Charging Guide Display

When you turn the power on, the color of the Charging Lamp ( ) (either white or red) will indicate the remaining battery level. If the lamp lights red, recharge the battery  before using the device again. The remaining battery level display will differ according to the condition of the battery and the usage environment.

Before Use

Charge the device

Using a household power outletYAMAN-SEYE-Home-Beauty-Device-Bloom-
EYE-5

You can check the remaining battery level through the Charging lamp.

Charging Lamp ( ) Display Charging Guide Display
White lighting The battery is sufficiently charged.
Red lighting Low battery.
Red flashing Charge the battery.
  • While charging, the Charge lamp will blink in white.
  • When charging is complete, the Charge lamp will light white for approximately five seconds and then turn off. Remove the USB cable.
  • At an indoor temperature of approximately 25°C, it will take about three hours to reach a full charge, at which point the device can operate for about 40 minutes. Actual charging time and operating time will differ depending upon the remaining battery level and the charging environment.
  • If charging does not begin after approximately 10 seconds, check whether the USB cable connection is loose.
    • If there is any moisture on or around the main body or charging terminal, be sure to wipe it dry. Charging the device while it is moist could cause damage to the battery.
    • Fully charge the battery before using the device for the first time after purchasing.
    • When using the device for the first time or when the device has not been used for an extended period of time, it is possible that you will be unable to use the device for very long even with a full charge displayed. In such a case, recharge the device before using it.
    • Use only the included USB cable.

Pre-testing on Skin

When using the device for the first time, always test for compatibility.

ATTENTION

  • Be sure to perform a pre-test in order to prevent skin problems from occurring.
  • If a rash, reddening, itchiness, stinging sensation, or other abnormality occurs at the pre-testing site, immediately stop the pre-test.
  • Check carefully to make sure there are no skin abnormalities before using the device. Stop using the device immediately if the treatment does not agree with your skin.
  1. Wash the inner side of your arm with soap and water, then wipe dry with a towel.

  2. Apply the skin-care product (about one pearl-sized drop) evenly to the test site on your arm, turn the power on, and then use the device for about 2.5 minutes while moving it across the skin (page 13).
    Be sure to test at Level 1.

  3. Rub the skin-care products remaining on your skin into the skin and check for any abnormalities.
    Continue to use the product only if you experience no reddening or burning sensation on your skin within 24 hours.YAMAN-SEYE-Home-Beauty-Device-Bloom-
EYE-6

How to Use

Basic method of use

Be sure to remove makeup and wash your face before using the device.

  1. Turn on the device
    The Charging lamp and Level 1 lamp will be lit, and the radio frequency (RF), EMS, and micro-current will be output.

  2. Select the level
    Each time the Level button is pressed, levels can be adjusted. You can check the treatment level from the level lamp. Personal memory function
    The device remembers the level being used when last treatment ended, and returns to the same settings the next time it is switched on.
    ATTENTION Use only Level 1 upon first use and until you are accustomed to using.

  3. Apply the included skin-care product evenly on the site to be treated and then move the device so that the entire surface of the electrode head comes in contact with your skin
    Treat one eye at a time (pages 15-16).YAMAN-SEYE-Home-Beauty-Device-Bloom-
EYE-9Apply one pearl-sized drop of the skin-care product around the eye for each eye.

  4. Care for the skin after the treatment
    After treatment is complete, rub the remaining skin-care product into the skin and then use your usual basic skin-care products to condition the skin.

ATTENTION

  • If the device does not move smoothly, apply more of the included skin-care product.
  • Use in a position in which the entire surface of the electrode head comes in contact with your skin.
  • Be sure to move the device on your skin while using it.
  • If it feels too hot, move it a little more quickly or lower the level.
  • Try to use five times a week (once daily, up to five minutes).
    Areas you should not treat: Upper eyelids and the Adam’s apple
  • The device can be used around the eyes (lower eyelids, outer corner of the eye)

How to move the device

Repeat the movements ① to ② within the specified time for a total of five sets as shown below.

  1. STEP1:
    Gently move from under the eyes to the temples, then move slowly in a circle.

  2. STEP2:
    Gently move in circles between the eyebrows, then slowly pull upward along the bone above the eyes. * If you want to focus on the under-eye area, use only step 1 for 2.5 minutes

Left side

  • Recommended speed for moving the device: 1 to 2 cm/second
  • Recommended duration of use: approximately 2.5 minutes per eye for a total of  5 minutes (the entire area around both eyes)
  • If you want to stop the treatment during use, press the Power button for at least one second to turn off the power.
  • After approximately 2.5 minutes, a long beep will sound and the device will enter Standby mode. To restart, press the power button.
  1. STEP1:
    Gently move from under the eyes to the temples, then move slowly in a circle .YAMAN-SEYE-Home-Beauty-Device-Bloom-EYE-14

  2. STEP2:
    Gently move in circles between the eyebrows, then slowly pull upward along the bone above the eyes.

  • If you want to focus on the under-eye area, use only step 1 for 2.5 minutes.
Right side

ATTENTION

  • Do not use it continuously in the same area for more than five minutes. Failure to comply may cause skin problems.

After Treatment

How To Clean

Clean the device after each use for hygienic reasons.

WARNING

  • When cleaning the device, be sure to turn it off and disconnect the USB cable from the main body.
    Failure to comply may cause an electric shock, short circuit, or fire.

  • Do not wash the device in water. This device is not waterproof. Doing so may cause a failure of the device.

Wipe off any dirt using a well-wrung soft cloth or similar material.

  • For stubborn stains, wipe gently with a cloth soaked in a diluted neutral detergent.
  • Remove any skin-care products remaining between the electrode ring of the electrode head with a cotton bud or cotton pad.

ATTENTION

  • Do not leave the device with the included skin-care product on it.
  • Do not wipe the device with solvents such as alcohol, thinner, benzene, nail polish remover, kerosene, chemicals, or polishing powder.

Storage

  • Store in a clean, well-ventilated place out of the reach of children.
  • Remove the USB cable from the main body when not in use for a long period of time.
  • Do not leave the device in hot or humid places, such as near flames, in bright sunlight, or in a bathroom.

Maintenance and Inspections

  • If you have not used the device for an extended period, inspect it carefully and check that it works properly and safely before using it again.
  • If the device is malfunctioning, go to ‘Troubleshooting’ (page 19) and attempt to identify the problem before requesting a repair. If the problem persists, contact your local distributor, making sure that you have your purchase details at the ready when you call.
  • If the device malfunctions, appears damaged, or needs service, please contact your local distributor.

Additional Information

Troubleshooting If you perceive any abnormality while using the device, verify the following points before arranging to have it repaired.

Frequently Asked Questions

  • What is the recommended duration and frequency of use?
    Try to use five days a week (once daily, up to five minutes). When using on the same area again, be sure to leave an interval of 24 or more hours between treatments.

    • The device can also be used on the face except for the eyes. Please observe your skin condition and use the device accordingly.
    • Check carefully to make sure there are no skin abnormalities before using the device. Stop using the device immediately if the treatment does not agree with your skin.
  • How much of skin-care product should I use each time?
    Apply about one pearl-sized drop of the included skin-care product on each eye area (about two pearl-sized drops for both eyes).
    It is possible to use skin-care products that you already own if they are water-soluble.
    If you are using skin-care products that you already own, use the recommended usage amounts as a guide. We recommend using gel skin-care products. If you feel that the amount of skin-care product is insufficient, add more.

  • Can I use the device in the bathroom?
    This device is not waterproof. Do not use the device in the bathroom.

  • My skin feels hot after use.
    This is due to the heat of the radio frequency (RF).

  • The electrode head does not warm-up
    The radio frequency (RF) does not warm the electrode head. Rather, it uses the power of electricity to warm your skin.

  • Do different levels produce different effects?
    As the levels increase, your skin is warmed more quickly and strongly. You will also feel the EMS more strongly.

  • Use only Level 1 when starting until you are accustomed to use.

Product specifications


Rated power supply

| ****

DC5V 1.0A

---|---


Power consumption

| ****

Approximately 2W (when charging)


Battery

| ****

Lithium-ion battery


Charging time

| Approximately 3 hours

(May vary depending on the charging environment.)


Operating time

| Approximately 40 minutes (when fully charged) (May vary with conditions of use and the EMS level.)


Outside dimensions

| ****

W 36 × D 41 × H 148 (mm)

Weight| Approximately 103 g
Materials| Main body: ABS resin and polycarbonate

Electrode head: Stainless steel


Country of origin

| ****

Japan


Accessories

| USB cable (USB Type-C™)……………………………….. One

Flawless Serum Moisture 20G Flawless Serum Smooth 20G User’s Manual

Recommended environmental temperature| 10°C to 40°C

After-sales Service

About the skin-care product included with the device
Please contact your local distributor for detailed information on products and purchases.

  • Sales may be discontinued without prior notice.
Rechargeable battery
  • The rechargeable battery is a consumable item. (not covered by the product warranty)
  • If the device no longer operates for more than a short period of time even after the battery has been recharged, the battery may have reached the end of its service life (the battery is expected to last 300 charge cycles).
  • If you need a battery replacement, contact your local distributor.
  • This appliance contains batteries that are only replaceable by skilled persons.
Disposing of the device
  • Follow your local government rules for proper disposal of this product.

  • This product uses a lithium-ion battery.

  • How to remove the built-in battery
    The lithium-ion battery used in this product is a valuable recyclable resource.

  • The battery must be removed from the appliance before it is disposed of.

  • The device must be turned off and disconnected from the charging cable when removing the battery.

  • Use a screwdriver to remove the battery. Be careful not to injure yourself.

  • When removing the battery, be careful not to damage it on a hard object, etc. * Failure to comply may cause the generation of heat or a fire.

  • Follow your local government rules for proper disposal or recycle of this product.

Operation Steps

Refer to figures ① to ④ below to remove the battery.

  1. Remove the sticker from the bottom of the product and unscrew one of the screws. Upper housing
  2. Slide the upper housing of the device, remove the upper and lower housings, and disconnect the cable connector.
  3. unscrew the four screws on the lower housing and remove the battery compartment.
  4. Remove the battery from the battery compartment.
    Do not damage the battery!
    This figure is intended to be used for disposing of the product, not repairing it. CAUTION: Disassembling/repairing the device by yourself may cause a failure.YAMAN-SEYE-Home-Beauty-Device-Bloom-EYE-18

Contacts for overseas customers

For countries and regions outside Japan, please contact to the store where you have purchased your product for any inquiry about the product. Alternatively, check YA-MAN Global Official Website (https://www.ya-man.com/en/)
Correct Disposal of this product

This marking indicates that this product should not be disposed of with other household wastes throughout the UK and EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

YAMAN User Manuals

Related Manuals