AIRCARE MA0800 Essick Air Humidifier Instruction Manual

June 5, 2024
AIRCARE

AIRCARE MA0800 Essick Air Humidifier

IMPORTANT SAFETY INSTRUCTIONS READ BEFORE USING YOUR HUMIDIFIER

WARNING: To reduce the risk of fire, electric shock, or injury, always unplug the unit before moving, filling, servicing, or cleaning. Do not pour or spill water onto the controls or motor area. If these get wet, let them dry completely and have the unit checked by authorized service personnel before plugging in. Do not use the humidifier if any parts are damaged or missing. Contact us for replacement parts at 800.547.3888.

  1. To reduce the risk of fire or shock hazards, this humidifier has a polarized plug (one blade is wider than the other). Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit into the Outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
  2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazards, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.
  3. Always unplug the unit before moving, cleaning, or removing the fan assembly section from the humidifier, or whenever it is not in service.
  4. Keep the humidifier clean. To reduce the risk of injury, fire, or damage to humidifiers, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible, or poisonous materials to clean your humidifier
  5. Do not put foreign objects inside the humidifier.
  6. Do not allow the unit to be used as a toy. Close attention is necessary when used by or near children.
  7. To reduce the risk of electrical hazard or damage to a humidifier, do not tilt, jolt or tip the humidifier while the unit is running.
  8. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.
  9. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.

HUMIDIFIER TWO-YEAR LIMITED WARRANTY POLICY

SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS
This warranty is extended only to the original purchaser of this humidifier when the unit is installed and used under normal conditions against defects in workmanship and materials as follows:

  • Two (2) years from the date of sale on the unit, and
  • Thirty (30) days on wicks and filters, which are considered disposable components and should be replaced periodically.

The manufacturer will replace the defective part product, at its discretion, with return freight paid by the manufacturer. It is agreed that such replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Warranty Exclusions: We are not responsible for the replacement of wicks and filters. We are not responsible for any incidental or consequential damage from any malfunction, accident, misuse, alterations, unauthorized repairs, abuse, including failure to perform reasonable maintenance, normal wear and tear, nor where the connected voltage is more than 5% above the nameplate voltage. We are not responsible for any damage from the use of water softeners or treatments, chemicals, or descaling materials. We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to repair and/or replace parts. No employee, agent, dealer, or other person is authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all labor costs incurred. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. Obtaining Warranty Service: Within the limitations of this warranty, purchasers with inoperative units should contact customer service at 800.547.3888 for instructions on how to obtain service within the warranty as listed above. This warranty gives the customer specific legal rights, and you may also have other rights which vary from province to province, or state to state. Register your product at www.aircareproducts.com.

LET’S GET YOU UP AND RUNNING

Remove the Mini-Console from its packaging You should have

  • Top (fan assembly)

  • Base

    831187-1

  • MAF2 Super Wick®
    ALL MAF2 WICKS

  • Float

    831189

  • Float support and one screw
    (installed in base)
    SUPPORT #831188-1 ISCREW #829815

  • Water bottle

    831199

  • Water bottle cap

    1B73170

  • Demineralization cartridge

    AU5003PK

  • Six rubber feet

    831190

  • Owner’s manual

    1B73372

Put your Mini-Console in the most centrally-located room of your home. It should be on a level surface against an interior wall. Make sure it’s at least two inches from the wall so the humidistat (on the cord) can accurately read your humidity.

More about positioning:

  • To maximize humidity circulation, put your unit near a cold air return.
  • If you prefer to put your unit in the room where humidity is most needed, you can! But the humidity won’t circulate as well with this method.
  • Don’t put your humidifier under a window, as condensation may occur.
  • Put the unit on the bottom floor of a multi-story home.

Remove the water bottle from the base and unscrew the water bottle cap. Take the demineralization cartridge from the parts bag and screw it into the water bottle cap. Fill the water bottle, then put the cap back on. Tighten the cap with your hands, making sure the cap is correctly threaded.

About water additives:

  • Do not use essential oils in your Mini-Console.
  • Do not use water softeners.
  • We recommend our Essick Air Bacteriostat to help inhibit mold growth.

Put the water bottle in the base and let the bottle drain completely. Make sure the plunger in the cap connects with the post in the base. Remove the bottle and refill it. Put the bottle back into the base. Filled twice like this, your Mini-Console holds 2.5 gallons of water. Wait 20 minutes for the wick to become fully saturated, then proceed to step 8. Plugin your unit and press the power button Set your desired fan speed by pressing the fan button. Your Mini-Console has three fan speeds that are displayed by F1 (the lowest speed) through F3 (the highest speed). The additional AUTO setting (displayed by an A) allows the fan speed to adjust automatically to your humidity setting.

Note: On higher speeds, the Mini-Console puts out a tremendous amount of humidity, so it’s louder on these levels. Most of our customers liken it to the sound of a box fan. Rest assured there is nothing wrong with your unit, it’s just working very hard to put out much-needed humidity.

Press the humidity control button to set your humidity level from 25% to 65%. The humidistat on your cord will read your home’s humidity and turn your fan off when the set level is reached. When set to 65%, your unit will run continuously. That’s it! Your Mini-Console is ready to use.

ABOUT THE CODES

  • The F code means your unit is empty and needs to be FILLED with water.
  • Your CONTROLS ARE LOCKED on the current setting. Activate the control lock by holding the power button for five seconds, until CL appears. Your Mini-Console will lock on the current fan and humidity settings. Release the lock by pressing the power button again for five seconds until the display flashes CL twice, letting you know the lock is off.
  • The CF code triggers after 720 hours of use and means it’s time to CHECK YOUR FILTER (wick). Unplug your unit and check your wick. If your wick is still in good shape, simply clear the code by plugging your humidifier back in. If your wick needs replacing, follow these quick steps:
  1. Remove the water bottle and top from the base.
  2. Replace your old wick with a new MAF2 Super Wick®. Wrap the wick through the base guides in a circle so the wick’s ends meet.
  3. Put the top and water bottle back on the base.

HOW TO CLEAN YOUR MINI-CONSOLE

Regular cleaning is important for preventing mold, mildew, and other bacterial growth in your humidifier. It also keeps your Mini-Console working its best.

  1. Let the unit run until it’s empty, then turn it off and unplug it.
  2. Remove the water bottle and the top from the base.
  3. Throw your wick away if it is time to replace it. Otherwise, remove it from the base and put the wick in a sink while you finish cleaning your Mini-Console.
  4. Pour out any remaining water from the base and bottle.
  5. Clean the base and bottle by filling each half-full with water. Add 1 cup of white vinegar to each. Let these sit for 20 minutes. To disinfect, replace the vinegar with 1 teaspoon of bleach in each. Do not mix vinegar and bleach.
  6. After 20 minutes, empty the base and bottle.
  7. Dampen a sponge with white vinegar and wipe down the base. Rinse it thoroughly. To disinfect, replace the vinegar with bleach.
  8. Wipe everything dry. Replace your wick or install a new one, then reassemble the unit.

When storing your Mini-Console, discard the used wick and disinfect the unit using the directions above. Dry the unit thoroughly, and store it in a temperature-regulated area. Do not install a new wick until you are ready to use your humidifier again. If you are missing any parts, or need replacement parts, call us at 800.547.3888 or visit our website aircareproducts.com.

Prefer to see a video?

Watch the Mini-Console set-up at aircareproducts.com/support. SCAN THE CODE TO THE RIGHT WITH YOUR PHONE’S CAMERA

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AIRCARE User Manuals

Related Manuals