YAMAN M21-1-001E Home Care Beauty Device Photo PLUS Prestige SS User Manual

July 17, 2024
YAMAN

YAMAN M21-1-001E Home Care Beauty Device Photo PLUS Prestige SS

Product Information

  • This YA-MAN beauty device is designed to provide home-care beauty treatments for the skin.
  • It utilizes LED light technology and cooling functions to enhance skin appearance and address various skin concerns.

Product Usage Instructions

  • DANGER: Improper use of the device poses a severe risk of death or serious injury.
  • WARNING: Improper use may pose a risk of death or serious injury.
  • ATTENTION: Be cautious to prevent injury or property damage.

Avoid use by individuals with electronic medical devices to prevent malfunctions. Consult a physician if unsure.

  • Do not continuously use on the same area, except in specific modes. Move the device across the skin during use.
  • Avoid using on areas unreachable by the electrode head to prevent burns or low-temperature injuries.
  • Keep away from children and ensure they do not handle the device.
  • Avoid exposure to fire, flames, or high temperatures to prevent accidents.
  • Use only the provided AC adapter and avoid overloading electrical circuits.
  • Avoid using near-flammable substances to prevent fire hazards.

Only use the device for purposes stated in the User’s Manual to prevent injuries or malfunctions.

Thank you for purchasing this YA-MAN product.

  • Please read this User’s Manual carefully for information on how to use the device properly and safely.
  • After reading the contents hereof, be sure to keep this User’s Manual in an accessible location.
  • Be sure to include this User’s Manual if you are transferring ownership of the device to another person.

Safety Precautions

  • Read these Safety Precautions carefully before using the device in order to use it correctly.
  • Use the device sensibly under the prescribed steps.
  • Immediately discontinue use and arrange to have the device repaired if any abnormality occurs.
  • Do not use the device while it is in a defective state, as doing so could cause physical harm to the user.
  • The precautions listed in the User’s Manual are very important. For your safety, please follow them carefully.
  • Precautions are classified as DANGER, WARNING, or ATTENTION to clearly specify the level of danger and possible injury or damage that may occur if the device is misused.

Classifications of Precautions

DANGER       Improper use of this device poses a severe and likely risk of death or serious injury.

WARNING    Improper use of this device may pose a risk of death or serious injury.
Improper use of this device may cause an injury or property damage*.

ATTENTION * ‘Property damage’ refers to damage affecting a dwelling, household belongings, or domestic animals and pets.

Symbols

This symbol shows you what you must not do.


This symbol shows you what you must do.

This symbol shows you what you must be careful with.

DANGER

The following individuals should not use the device:

  • Use of the device could cause electronic medical devices to malfunction.
  • Do not use the device in conjunction with any medical electronic equipment, including:
    • pacemakers or other implanted electronic medical devices,
    • artificial heart-lung machines or other electronic life-support medical devices, and
    • electrocardiographs or other worn electronic medical devices.

WARNING

The following individuals should not use the device:
Failure to comply may cause an accident or other problems.

  • If you are under a doctor’s care
  • If you are in a physical growing stage
  • If you have an acute disease
  • If you have tuberculosis
  • If you have a fever
  • If you are suffering from hypertension
  • If you have an infectious disease
  • If you have a malignant tumor
  • If you have a blood disease
  • If you have a visceral disease
  • If you have a skin disease
  • If you have an allergic constitution
  • If you have atopic dermatitis
  • If you have skin problems
  • If you are severely fatigued
  • If you have sensitive skin
  • If you are physically unwell
  • If you are under the influence of alcohol
  • If you have excessive myopia (-6D or higher)
  • If you have had an eye or face operation
  • If you have any disease of the eyes or face, or are currently undergoing treatments
  • If you are pregnant, nursing or during menstruation
  • If you take medication that induces drowsiness
  • If you have unhealthy skin blemishes caused by physical irritation
  • If you have capillary dilatation due to long-term use of steroid hormonal drugs or a liver disorder
  • If you are experiencing skin irritation or redness due to sunburn

Prohibition

  • Do not use the device on the areas indicated below or outside of specified areas.
  • Failure to comply may cause an accident or other problems.
  • Cuts
  • Areas where surgery (including plastic surgery) was performed
  • Anywhere inside the mouth, around the pubic region, or any mucous membrane
  • Acne
  • Bulging moles
  • Viral warts
  • The Adam’s apple
  • Eyeballs
  • Areas where skin suffers from purulent inflammation
  • Areas with itchiness or hot sensations
  • Eyelids or around the eyes (except in EYE Mode and COOL Mode)
  • The LED light can be used around the eyes and eyelids. Close your eyes and hold the device at least 5 cm away from the skin. Do not look directly into the LED light.

If you are uncertain as to whether it is safe to use the device, consult a physician prior to use.

  • Do not use continuously on the same area except when in EYE Mode or COOL Mode. Be sure to move the device across the skin while it is in use. Do not use on areas that cannot be reached by the entire electrode head surface
  • Failure to comply may cause burns or low-temperature injuries.
  • Do not place the device near fire or flames, and do not dispose of the device in a fire. Do not use or store in a high-temperature place or if the device is hot.
  • Failure to comply may lead to the generation of heat, a fire or an explosion.

User Restrictions

  • Failure to comply may cause an accident or injury.

Non-intended uses are prohibited

  • Do not use the device for any purpose other than those stated in the User’s Manual.
  • Failure to comply may cause an injury or malfunction.

Prohibition

  • Do not use the device near a flammable substance (such as alcohol, thinner, benzene, nail polish remover or spray).
  • Failure to comply may cause a fire, electric shock or an injury.

Overloading of an electric circuit is prohibited

  • Make sure to use the dedicated AC adapter for this device. Plug the AC adapter directly into a wall power outlet and do not overload the electric circuit.
  • Failure to comply may cause an electric shock, short circuit or fire.

User Restrictions

  • Do not allow people who are unable to express their intentions on their own to use the device. Use by unattended people with physical disabilities should be avoided.
  • Failure to comply may cause an accident or injury.

Prohibition against use when an abnormal odor or excess heat is detected

  • If any problem occurs during use, including the presence of an abnormal odor or excess heat, stop using the device.
  • Failure to comply may cause the device to become damaged or catch fire.

Must Comply

  • Before charging, make sure there is no moisture on or around the adapter plug or plug socket.
  • Failure to comply may cause an electric shock, short circuit or fire.

Careless or reckless use is prohibited

  • Do not cut, damage, modify, excessively bend, pull, twist or wrap the AC adapter cord.
  • Placing a heavy item on top of the AC adapter cord or pinching it between other items, could damage it and cause fire or electric shock.

Use of a damaged cable or plug is prohibited

  • Do not use if the AC adapter is damaged or the wall socket is too loose.
  • Failure to comply may cause an electric shock, short circuit or fire. Contact your local distributor for advice on repairing the device.

Exposure to water is prohibited

  • Do not use the AC adapter in the bathroom or areas where there is water. Do not wash or immerse the main unit or AC adapter in water.
  • Failure to comply may cause an electric shock, short circuit or fire.

Disassembly is prohibited

  • Do not disassemble, attempt to repair, or modify this device in any way.
  • Failure to comply may cause a fire, electric shock or injury. Contact your local distributor for advice on repairing the device.

Must Comply

  • Be sure to turn off the power when not in use or when cleaning the device.
  • Failure to comply may cause an electric shock, short circuit or fire.

Must Comply

  • Use in an operating voltage range between 100 and 240 volts. Make sure the AC adapter is fully inserted into the electrical outlet.
  • Failure to comply may cause a fire, electric shock or other accidents.

Disconnecting the AC adapter

  • Be sure to disconnect the AC adapter from the outlet when the device is not in use. Do not insert or disconnect the plug with wet or damp hands.
  • Failure to comply may cause an electric shock, short circuit or fire.

Removing the plug

  • When unplugging the AC adapter from the main unit or a power outlet, do so by gripping the plug. Do not insert or disconnect the plug with wet or damp hands.
  • Failure to comply may cause an electric shock, short circuit or fire.

Fire/Explosion warning

  • Do not leave the device in hot or humid places, such as near flames, in bright sunlight or in a bathroom. Do not bring the device close to a heater.
  • Failure to comply may lead to the generation of heat, a fire or explosion.

Disconnecting the AC adapter

  • In the unlikely event that an abnormality occurs, immediately unplug the AC adapter.
  • Do not use the device if smoke, abnormal noises or an odor is detected, or if it is otherwise operating in an abnormal state.

ATTENTION

  • Never use the device on prohibited areas
  • Those who are currently undergoing dental treatment or have dental fillings may experience unpleasant sensations in their teeth due to the ion/EMS/DYHP stimulation.
  • Choose a lower level and apply the device to a different area.

Refrain from the following actions

Prohibition

Failure to comply may cause an accident, injury or a malfunction of the device.

  • Do not use the device if your skin is experiencing a rash, inflammation, itchiness or other abnormalities.
  • Do not use if damaged due to dropping or an impact with another item.
  • Do not use the device continuously for an overly long period (for example, through commercial use).

Prohibition

  • Do not wipe the device with alkali cleaning agent, alcohol, thinner, benzene, nail polish remover or any other solvents.
  • Failure to comply may cause damage to the surface of the device.

Prohibition

  • Avoid allowing the electrode head to come into contact with any other metal surfaces.
  • Failure to comply may result in a malfunction of the device or injury.

Prohibition

  • Do not use the device on pets.
  • Failure to comply may cause an injury.

Dropping of the device is prohibited

  • Do not place the device in an unstable location. Do not drop or strike the device.
  • Failure to comply may lead to a malfunction of the device. An injury may also be caused if the device is dropped on a foot or other body parts.

Prohibition

  • Do not look directly into the LED light.
  • When using the LED light to treat areas around the eyes and the eyelids, be sure to close your eyes and keep the electrode head at least 5 cm away from the skin.
  • Failure to comply may cause damages to your eyes or skin.

Prohibition

  • Do not use COOL Mode continuously.
  • If the mode is used for continuous treatments, the head will not become fully cool.
  • Have an interval of at least 30 minutes between treatments.

Must Comply

Be sure to comply with the following points.

Failure to comply may cause an accident, injury or a malfunction of the device.

  • Do not use continuously on the same area.
  • Use the device appropriately based on your skin condition.
  • Do not use the device after sunbathing, or in combination with peelings, skin packs or other treatments.
  • Be sure to turn the device off after use.

Must Comply

  • Stop using the device if you feel any physical discomfort during use.
  • Check carefully to make sure there is no skin abnormality before using the device.
  • Stop using the device immediately if the treatment does not agree with your skin.

Must Comply

  • Use only Level 1 upon the first use and until you are accustomed to use.
  • Failure to comply may cause an accident or injury.

Must Comply

  • Be sure to use in an operating voltage range between 100 and 240 volts.
  • Failure to comply may cause a fire, electric shock or failure of the device.

Combustion warning

  • Be sure to check the plug configuration and the voltage of the power outlet before use.
  • Failure to comply may cause a generation of heat, fire or malfunction of the device.

The plug configuration and voltage may vary depending on the region and the type of accommodation.

  • Always be sure to check for compatibility before using the device.
  • For information about plug adapters, consult a travel agency or a consumer electronics retailer.

Features

This product is a facial beauty device that provides skin care through ion cleansing, ion moisture, EMS, DYHP, Photo, micro-currents, cooling, vibration functions and while warming the skin through RF (Radio Frequency).
It can be used to match your personal skin condition and to achieve your objective by combining the following available treatment modes:

  • RF: Deeply warming the skin* to create better conditions for the treatment.
  • Ion Cleansing: Uses the power of ions to absorb dirt that cannot be removed with normal face washing.
  • Ion Moisture: Incorporates ions with original waveforms, enabling skin lotion to penetrate* to the skin.
  • EMS: Stimulates the muscles with an electrical current.
  • DYHP: Assists skin lotion to penetrate the skin using electrical pulses with unique waveforms.
  • Photo: Treats your skin with LED Photo treatment.
  • Micro-currents: Treats the skin around your eyes with weak electric currents.
  • Cooling: Tightens skin with a cooling effect.
  • Vibration: Supports skin care with gentle vibrations.

Accessories

Cotton Stopper (Silver Ring)

  • The cotton stopper is attached to the electrode head when purchased.
  • Use this stopper to fix cotton to the electrode head.

AC Adapter

  • The design and specifications of the device and accessories are subject to change for improvements without prior notice.

Names of Components

Main Unit

YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-Prestige-SS-
FIG-9

Before Use

How to operate/How to read the display

Indicator and Buttons

  • Connect the AC adapter to the adapter plug insertion port on the main unit and the wall socket to turn the device on (The device will be in Standby Mode).
  • Press and hold the button for the mode you wish to start.
  • For CLEAN and MOIST Modes, there are five levels from which you can select.
  • For EYE Mode, there are three levels from which you can select.
  • Treatment level is not available for COOL Mode.
  • For vibrations, you can select on/off and vibration patterns using the Vibration (VIB) button.
  • There are three vibration patterns which you can select.
  • Please select the vibration pattern you prefer. VIB 1 ⇒ VIB 2 ⇒ VIB 3 ⇒ OFF ⇒ VIB 1…

Modes

YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-Prestige-SS-
FIG-11

Level Indicator

  • There are five levels for CLEAN and MOIST Modes, and three levels for EYE Mode.
  • Each time the CLEAN or MOIST button is pressed, the level switches as shown in the below picture.
  • There is no level selection available for COOL Mode.
  • Use only Level 1 upon the first use and until you are accustomed to use.

YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-Prestige-SS-
FIG-12

How to Use EYE Mode

  • This mode cares for the skin around the eyes using two electrodes on the electrode head.
  • Rotate the electrode head 180° to switch between EYE Mode and Standby Mode.
  • The electrode head only rotates in the direction of the arrow shown in the figure on the right.
  • The device cannot be operated in Eye Mode if the electrode head is not rotated 180°.
  • In addition, the device cannot be used in other modes while the electrode head is rotated.

Timer

  • One short beep will sound to indicate the half-way point in the operation time.
  • Refer to pages 9 -10 for operation times in each mode.

Standby Mode

  • When treatment on a certain mode is completed, two short beeps sound and the device switches to Standby Mode (the state in which functioning is suspended). Refer to pages 9 -10 for operation times in each mode.
  • Press and hold the mode button again to start the selected mode.

Pre-testing on Skin

  • When using the device or a cosmetic product for the first time, always test for compatibility.

Clean your skin

  • Wash the inside of your wrist with soap, then wiping it dry with a towel.

Apply skin-care product (gel or lotion) or water on your arm.
Use the device for approximately 3 minutes in MOIST Mode

  • Do not wet or rub the pre-testing area.

If you experience any skin abnormality (redness or burning sensation) at the pre-testing area within 24 hours, stop using the device.

ATTENTION

  • Be sure to perform a pre-test in order to prevent skin problems from occurring.
  • If a rash, reddening, itchiness, stinging sensation or other abnormalities occur at the pre-testing area, immediately stop the pre-test and wash the area.
  • Check carefully to make sure there is no skin abnormality before using the device.
  • Stop using the device immediately if the treatment does not agree with your skin.

How to Use

How to attach cotton to the electrode head

  1. Remove the cotton stopper from the electrode head.
  2. Place a piece of cotton on top of the electrode head and press the cotton stopper down over the cotton.
    • If the cotton stopper does not fit properly on the electrode head, please use a larger and thinner piece of cotton. Because thick cotton pads are difficult to fix in place, split them in half before use.
    • If the cotton is too thick, the thermal action of RF treatment may be adversely affected and you will feel less heat.
  3. Apply your regular skin lotion or gel onto the cotton.
    • Make sure the skin lotion or gel coats the entire surface of the electrode head.
    • If using a waterly (low-viscosity) skin lotion, the feeling of warmth may decrease.
    • Recommended skin lotions: RF Booster Pad (page 21) or high-viscosity skin lotions.
    • If the cotton pad becomes dry, add more skin-care product. Cotton pads may easily come off from the device when they are dry.

How to Use (General Instructions)

Precautions

  • Be sure to move the device on your skin while using it. Using the device continuously on the same area may cause burns or other injuries (except when using the device in EYE Mode or COOL Mode).
  • The warmth of the RF changes depending on the type of skin-care product used and the skin’s condition at the time of treatment.
  • Do not use this device around the eyes unless it is in EYE Mode or COOL Mode.
  • The LED light can be used around the eyes and eyelids. Close your eyes and hold the device at least 5 cm away from the skin.
  • Do not look directly into the LED light.
  • When holding the device, make sure that you are holding the hand electrode.
  • The recommended ambient temperature is 15° C to 30°C.

Treatment Method

  • Remove makeup and gently cleanse your face.

    • Remove oil and dirt from your skin so that it is in a clean condition prior to treatment.
    • COOL Mode can be used over makeup.
  • Attach cotton if necessary and apply skin lotion onto the cotton.

  • Connect the AC adapter to turn the power on.

    • Press the mode button and select a mode and intensity level.
    • First, press and hold the button of the mode you wish to use to start. Then press the button again briefly to select the level.
    • Start using the device in EYE Mode only after rotating the electrode head.
    • The intensity level cannot be selected for COOL Mode.
    • Always select Level 1 upon the first use until you are accustomed to use.
  • When holding the device, make sure that you are touching the hand electrode (silver rim) on the rear of the device.

  • Gently apply the treatment head to your skin and move the head over the area being treated. Refer to pages 15-16 for more details.

    • When operation in each mode is completed, the device will switch to Standby Mode. To start the next mode, press and hold the relevant mode button.
    • During use, make sure the electrode head is closely touching the skin.
    • If you wish to stop the mode you are using half-way through the operation, press and hold the relevant mode button.
  • Unplug the AC adapter from the main unit and the wall socket to turn the power off.
    After treatment, condition your skin as necessary.

    • Please apply skin cream as appropriate.
    • Clean the main unit after each use.

How to use the device on your skin

  • Recommended speed for moving the device: approximately 2 cm per second
  • If the temperature feels too hot, move the electrode head more quickly.
  • One short beep will sound to indicate the half-way point in the operation time.
  • Change to the other side of your face when you hear this beep.
  • Use the device in a position in which the entire surface of the electrode head comes in contact with your skin.
  • Be sure to move the device over the skin while you are using it (except when using the device in EYE Mode or COOL Mode).
  • Placing the device continuously on the same area may cause burns or low-temperature injuries.
  • Do not use the device on the eyelids or around the eyes.
  • The Eye Mode electrode can be used around the eyes.

< CLEAN Mode>

  • Move the electrode head over the skin in the direction of the arrows shown below.
  • The LED light can be used to treat the area around the eyes and the eyelids.

YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-Prestige-SS-
FIG-16

< MOIST Mode>

Move the electrode head over the skin in the direction of the arrows shown below.

YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-Prestige-SS-
FIG-17

< EYE Mode>

  • Rotate the electrode head 180° so that the EYE Mode electrode is at the top.
  • Make sure that both electrodes are touching the skin, press the electrode head down repeatedly from the inner to the outer corner of the eye as if stamping the skin:
  • Press → Release → Move electrode head.
  • Press down on the skin for approximately 3 seconds.
  • Do not use the device on the eyelids.
  • Be sure not to press down continuously on the skin for longer than 3 seconds.

YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-Prestige-SS-
FIG-18

< COOL Mode>

  • Press the electrode head repeatedly on your face as if stamping on the skin (Press → Release → Move electrode head).
  • The device can also be used around the eye area.
  • When using the LED light on the eyelids, be sure to close your eyes and keep the electrode head at least 5 cm away from the skin.

After Treatment

How To Clean

To keep the product clean, please be sure to clean it after each use.

  1. Disconnecting the AC adapter
  2. To clean the device and electrode head, wipe them with a damp and well-wrung cloth to remove any dirt. Wash the cotton stopper with water after removing it from the main unit.
    • Refrain from using an alkali cleaning agent, alcohol, thinner, benzene, nail polish remover or any other solvents.
    • Do not leave the device with lotion or gel on it.
  3. Wipe the entire device with a dry cloth and store it after removing all moisture.

Storage

  • If you will not be using it for an extended period, clean the device before storing it.
  • When the device is not in use, disconnect the AC adapter from the main unit and wall outlet.
  • Avoid storing the device near a heater or in a bathroom or other high-temperature/high-humidity location.
  • Also, avoid locations where there is exposure to direct sunlight or unstable.
  • Keep the device out of the reach of children.

Maintenance and Inspections

  • If you will not use the device for an extended period, be sure to inspect it carefully and check that the device works properly and safely before restarting use.
  • If the device is malfunctioning, go to ‘Checklist for Possible Problems’ and attempt to identify the problem before arranging to have the device repaired. If the problem persists, contact your local distributor with a proof of purchase.
  • If the device malfunctions, appears damaged or needs a service, please contact your local distributor.

Troubleshooting

Checklist for Possible Problems

YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-Prestige-SS-
FIG-19 YAMAN-M21-1-001E-Home-
Care-Beauty-Device-Photo-PLUS-Prestige-SS-FIG-20 YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-
Prestige-SS-FIG-21 YAMAN-M21-1-001E-Home-Care-Beauty-Device-Photo-PLUS-
Prestige-SS-FIG-22

Frequently Asked Questions

Q A
How much lotion or gel should I use each time? This device is designed to

achieve better results with sufficient use of lotions and/or gel.

As a general guide, when using cotton pads, be sure the entire electrode head is moistened with face lotion.

Use about two pearl-sized drops of gel.

We recommend adding more lotion or gel if you feel there is not enough.

Can I use the device in the bathroom?

|

This product is not waterproof, so it must not be used in the bathroom.

Also, do not use the device near water (such as in a kitchen, washroom, etc.).

My skin feels hot after use.| This is due to the heat of the RF.

If it bothers you, use COOL Mode or apply blue ice to cool your skin down.

Why do I feel a tingly sensation on my face and hands?| This tingly sensation is caused by electrical stimulation from ions/EMS/DYHP.

It is possible to adjust the level using the mode button.

Use the device at a strength that feels comfortable for you.

Use only Level 1 upon the first use and until you are accustomed to use.

Why do I not feel warmth of RF when using CLEAN, MOIST or EYE modes?

|

Move the electrode head more slowly or press harder against the skin surface.

It is also possible that the moisture absorbed in the cotton is insufficient. Add more lotion or gel.

Why can’t I see any dirt on the cotton?| Dirt is removed even though it may not be visible on the cotton. The amount of visible dirt on the cotton can vary among individuals.

The electrode head does not warm up when I use RF mode.

|

The RF does not warm the electrode head. Rather, it uses the power of electricity to warm your skin.

After-sales Service

Disposing of the device

  • Follow your local government rules for proper disposal of this product.

Contacts for overseas customers

  • For countries and regions outside Japan, please contact the store where you purchased your product for any inquiries.
  • Alternatively, check the YA-MAN GLOBAL Official Website (https://www.ya-man.com/en/)

Recommended cosmetics

RF Booster Pad Pore Refining Deep Cleansing

  • Product name: RF Booster Pad Pore Refining Deep Cleansing
  • Quantity: One box contains 15 sachets of one sheet type (sufficient for approximately 1.5 to 2 months’ use)
  • Item No.: YRF0003

RF Booster Pad Clear Deep Moisturizer

  • Product name: RF Booster Pad Clear Deep Moisturizer
  • Quantity: One box contains 15 sachets of one sheet type (sufficient for approximately 1.5 to 2 months’ use)
  • Item No.: YRF0004

Official website: https://www.ya-man.com/en/

  • Sales may be discontinued without prior notice.

User’s Manual (Chinese version)
The Chinese-language User’s Manual can be viewed from the URL or QR code shown below.

Product Specifications

Rated Power Supply DC12V 3.0A
Power Consumption Approx. 20 W
Outside Dimensions Main unit (with a cotton stopper): Approx. W 50 x D 65 x H

185 (mm)
Weight| Main unit (with a cotton stopper): Approx. 230 g
Materials| Main unit: ABS resin. Panel: Polycarbonate

Electrode head: PET resin and stainless steel (chrome-plated) Hand electrode: ABS resin (chrome-plated)

Country of manufacture| Japan
Accessories| Cotton stopper, AC adapter
Rated Power Supply| 15°C~30°C

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals