GREEN CREATIVE 16PLL-840-GL-BYP Creative 16W LED PLL Bulb Installation Guide

June 5, 2024
GREEN CREATIVE

GREEN CREATIVE 16PLL-840-GL-BYP Creative 16W LED PLL Bulb Installation Guide
GREEN CREATIVE 16PLL-840-GL-BYP Creative 16W LED PLL
Bulb

Safety Instruction

WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. Installation should be performed only by a qualified electrician in accordance with the National Electrical Code and relevant local code.
WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING – Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.

  • Disconnect power at the source before installation, inspection or removal. Do not simply switch off fixture.
  • This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before installation.
  • Not intended for use with emergency exit fixtures or emergency exit lights.
  • Not for use with luminaire ballast.
  • Do not use if product is damaged.
  • Not for use with dimmers.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • “This luminaire has been modified to operate LED lamps” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including re-lamping.
  • Risk of fire or electric shock. Do not open or modify. No user serviceable parts inside.
  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
  • SUITABLE FOR DAMP LOCATIONS. Suitable for use in wet locations when used in an outdoor-rated fixture. Not for use where directly exposed to the weather or water.
  • Complies with Part 15 of FCC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation.
  • No external weight or mechanical force should be applied to tube or components.
  • THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
  • Models 17PLL/xxx/GL/BYP, 16PLL/xxx/GL/BYP, 17PLL/ xxx/ BYP/R are intended to retrofit surface mount, Type IC or non-IC recessed mount Listed fluorescent luminaires that use maximum three lamps with or without a diffuser, the minimum dimension of luminaries are tabulated below:
Model Number 17PLL/xxx/GL/BYP 17PLL/xxx/BYP/R 16PLL/xxx/GL/BYP
Lamp compartment of Luminaire, overall dimensions (cm) Length 61.5
Width 60.5 60.5
Height 10.5 10.5
Maximum Lamps in Luminaire 3 3
Lampholder-to-Lampholder Spacing (cm) 8.5 8.5

Models 10PLL/xxx/GL/BYP, 8.5PLL/xxx/GL/BYP intended to retrofit  surface mount Listed fluorescent luminaires that use maximum two lamps without a diffuser, the minimum dimension of luminaries are tabulated below:

Model Number 10PLL/xxx/GL/BYP 8.5PLL/xxx/GL/BYP
Lamp compartment of Luminaire, overall dimensions (cm) Length 44
Width 14 14
Height 10 10
Maximum Lamps in Luminaire 2 2
Lampholder-to-Lampholder Spacing (cm) 1 1

INSTALLATION STEPS

  1. Read all WARNINGS before continuing this section.

  2. Make sure POWER IS TURNED OFF at the source to the location at which you are installing the product.

  3. Remove lens, cover and fluorescent tubes. Cut away all wires connecting the ballast.

  4. Make sure to connect the line (L) and neutral (N) to the corresponding ends of the tube marked L and N. Note this product is double-ended,
    do not wire to a single end.

  5. Follow wiring diagrams for number of lamps and original ballast type.

  6. Visibly affix the “Modification Sticker” to the fixture and reinstall housing cover and lens if applicable.

  7. Return power back to the source and installation is complete.

1 LAMP

  • Cut all wires connected to the ballast, remove the ballast.
    Installation Instruction
    Installation Instruction

  • Rewire the fixture according to the wiring configuration.
    Installation Instruction

2 LAMPS

  • Cut all wires connected to the ballast, remove the ballast.
    Installation Instruction Installation
Instruction

  • Rewire the fixture according to the wiring configuration.

For model #: 17PLL/xxx/GL/BYP, 16PLL/xxx/GL/BYP, 10PLL/xxx/GL/BYP, 8.5PLL/xxx/GL/BYP ,17PLL/xxx/BYP/R
Where xxx means 824-965 which indicates CRI and color temperature

Contact Us

www.greencreative.com
[email protected]
Tel / Fax: 866-774-5433
 GREENCREATIVELED
GClightingLED
 GREEN-CREATIVE

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GREEN CREATIVE User Manuals

Related Manuals