GREEN CREATIVE T5 Universal Ended Bypass Installation Guide

June 9, 2024
GREEN CREATIVE

GREEN CREATIVE T5 Universal Ended Bypass logo

GREEN CREATIVE T5 Universal Ended Bypass

GREEN CREATIVE T5 Universal Ended Bypass product For model #: 9.5T5HE/2F/xxx/BYP, 12T5HE/3F/xxx/BYP, 14.5T5HE/4F/xxx/BYP, 11.5T5HO/2F/xxx/BYP, 14.5T5HO/3F/xxx/BYP, 25T5HO/4F/xxx/BYP,9.5T5HE/2F/xxx/BYP/R, 12T5HE/3F/xxx/BYP/R, 14.5T5HE/4F/xxx/BYP/R, 11.5T5HO/3F/xxx/BYP/R, 14.5T5HO/3F/xxx/BYP/R, 24T5HO/4F/xxx/UEB Where xxx means 824-965 which indicates CRI and color temperature
Pour les products suivants: 9.5T5HE/2F/xxx/BYP, 12T5HE/3F/xxx/BYP, 14.5T5HE/4F/xxx/BYP, 11.5T5HO/2F/xxx/BYP, 14.5T5HO/3F/xxx/BYP, 25T5HO/4F/xxx/BYP,9.5T5HE/2F/xxx/BYP/R, 12T5HE/3F/xxx/BYP/R, 14.5T5HE/4F/xxx/BYP/R, 11.5T5HO/3F/xxx/BYP/R, 14.5T5HO/3F/xxx/BYP/R, 24T5HO/4F/xxx/UEB Où xxx signifie 824-965 qui correspond au CRI et couleur de temperature
WARNING
WARNINGRisk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. Installation should be performed only by a qualified electrician in accordance with the National Electrical Code and relevant local code.
WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
WARNING – Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.

  • Disconnect power at the source before installation, inspection or removal. Do not simply switch off fixture.

  • This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before installation

  • Not intended for use with emergency exit fixtures or emergency exit lights.

  • Not for use with luminaire ballast.

  • Do not use if product is damaged.

  • Not for use with dimmers.

  • Suitable for use with non-shunted lamp holders only.

  • Connect hot wire only to end cap with the L and N markings.
    GREEN CREATIVE T5 Universal Ended Bypass 2Opposite end cap is dead, do not wire

  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation

  • To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lamp holders.
    Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-Start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example, F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.

  • “This luminaire has been modified to operate LED lamps” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including re-lamping.

  • Risk of fire or electric shock. Do not open or modify. No user serviceable parts inside.

  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.

  • SUITABLE FOR DAMP LOCATIONS. Suitable for use in wet locations when used in an outdoor-rated fixture. Not for use where directly exposed to the weather or water.

Complies with Part 15 of FCC.
Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received including interference that may cause undesired operation.
  • SUITABLE FOR “TYPE IC” OR “TYPE NON-IC” LUMINAIRES.
  • No external weight or mechanical force should be applied to tube or components.
  • THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITIES HAVING JURISDICTION.

INSTALLATION STEPS

  1. Read all WARNINGS before continuing this section.
  2. Ensure fixture is 120-277V.
  3. Make sure POWER IS TURNED OFF AT THE SOURCE.
  4. Remove lens if applicable, remove cover and fluorescent tubes.
  5. Cut all wires that connect ballast. Properly discard ballast or cap off wires. Cut wire away from lamp holders.GREEN CREATIVE T5 Universal Ended Bypass 3
  6. If applicable, replace lamp holders at power end with non-shunted lamp holders.
  7. Connect Live (L) from power source into non-Shunted lamp holder “L In”.
  8. Connect neutral (N) wire from power source into non-Shunted lamp holder “N In”.
  9. If installing a single tube and go to section 13. If connecting multiple lamps, continue reading.GREEN CREATIVE T5 Universal Ended Bypass 5
  10. Connect separate hot wire into “Hot Out” from primary source lamp holder and connect that wire into “Hot In” on the adjacent tube.
  11. Connect separate neutral wire into “Neutral Out” from primary source lamp holder and connect that wire into “Neutral In” on the adjacent tube. GREEN CREATIVE T5 Universal Ended Bypass 6
  12. Continue this process for additional lamps.
  13. This device is powered on one end only; the end with L and N markings . Do not wire opposite end of lamp holder.GREEN CREATIVE T5 Universal Ended Bypass 4
  14. Install lamp with the L and N markings into the wired lamp holder end.
  15. Visibly affix “Modification Sticker” and reinstall housing cover and lens if applicable.
  16. Return power back to source and installation is now completed.

For model #: 24T5HO/4F/xxx/UEB

Where xxx means 824-965 which indicates CRI and color temperature Pour les products suivants: 24T5HO/4F/xxx/UEB Où xxx signifie 824-965 qui correspond au CRI et couleur de temperature

INSTALLATION STEPS
  1. Read all WARNINGS before continuing this section.

  2. 2Make sure POWER IS TURNED OFF at the source to the location at which you are installing the product.

  3. Remove lens, cover and fluorescent tubes. Cut away all wires connecting the ballast. GREEN CREATIVE T5 Universal Ended Bypass 7

  4. Make sure to connect the line (L) and neutral (N) to the corresponding ends of the tube marked L and N. Note this product is double-ended, do not wire to a single end. GREEN CREATIVE T5 Universal Ended Bypass 8

  5. Follow wiring diagrams for number of lamps and original ballast type (instant start, programmed start or rapid start). GREEN CREATIVE T5 Universal Ended Bypass 9
    GREEN CREATIVE T5 Universal Ended Bypass 10
    GREEN CREATIVE T5 Universal Ended Bypass 11
    GREEN CREATIVE T5 Universal Ended Bypass 12

  6. Visibly affix the “Modification Sticker” to the fixture and reinstall housing cover and lens if applicable.

  7. Return power back to the source and installation is complete.