WARNING – Risk of fire or electric shock. LED Retrofit Kit installation
requires knowledge of luminaire electrical systems. Installation should be
performed only by a qualified electrician in accordance with the National
Electrical Code and relevant local code.
WARNING – Risk of fire or electric shock. Install this kit only in the
luminaires that have the construction features and dimensions shown in the
photographs and/or drawings.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to
edges of sheet metal or other sharp objects.
WARNING – Risk of fire or electric shock. Luminaire wiring and electrical
parts may be damaged when drilling for installation of LED retrofit kit. Check
for enclosed wiring and components.
WARNING – To avoid potential fire or shock hazard, do not use this
retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted
lamp holders are found only in fluorescent luminaires with Instant-Start
ballasts. Instant-start ballasts can be identified by the words “Instant
Start” or “LS.” marked on the ballast. This designation may be in the form of
a statement pertaining to the ballast itself, or may be combined with the
marking for the lamps with which the ballast is intended to be used, for
example F40T12/1S. For more information, contact the LED luminaire retrofit
kit manufacturer.
- Disconnect power at the source before installation, inspection or removal. Do not simply switch off fixture.
- This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before installation.
- Not intended for use with emergency exit fixtures or emergency exit lights.
- Not for use with luminaire ballast.
- Do not use if product is damaged.
- Suitable for use with non-shunted and shunted lamp holders.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- “This luminaire has been modified to operate LED lamps” shall be marked on the retrofit luminaire where readily visible by the user during normal maintenance including re-lamping.
- Risk of fire or electric shock. Do not open or modify. No user serviceable parts inside.
- Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
- SUITABLE FOR DAMP LOCATIONS. Suitable for use in wet locations when used in an outdoor-rated fixture. Not for use where directly exposed to the weather or water.
- Complies with Part 15 of FCC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received including interference that may cause undesired operation.
- SUITABLE FOR “TYPE IC” OR “TYPE NON-IC” LUMINAIRES.
- No extemal weight or mechanical force should be applied to tube or components.
- THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITIES HAVING JURISDICTION.
- The lamps are intended to retrofit surface mount, Type IC or non-IC recessed mount listed fluorescent luminaires that use maximum 4 tubular lamps.
- Read all WARNINGS before continuing this section.
- Ensure fixture is 120-277V.
- Make sure POWER IS TURNED OFF AT THE SOURCE.
- Remove lens if applicable, remove cover and fluorescent tubes.
- Cut all wires that connect ballast (Cf. Diagram 1). Properly discard ballast or cap off wires. Cut wire away from lamp holders.
- If applicable, replace lamp holders at power end with non-shunted lamp holders.
- Connect Live (L) from power source into non-Shunted lamp holder “L In”.
- Connect neutral (N) wire from power source into non-Shunted lamp holder “N In”.
- If installing a single tube refer to Diagram 3 and go to section 13. If connecting multiple lamps, continue reading.
- Connect separate hot wire into “Hot Out” from primary source lamp holder and connect that wire into “Hot In” on the adjacent tube.
- Connect separate neutral wire into “Neutral Out” from primary source lamp holder and connect that wire into “Neutral In” on the adjacent tube. See Diagram 4 below.
- Continue this process for additional lamps.
- This device is powered on one end only; the end with L and N markings (Cf. Diagram 2). Do not wire opposite end of lamp holder.
- Install lamp with the L and N markings into the wired lamp holder end.
- Visibly affix “Modification Sticker” and reinstall housing cover and lens if applicable.
- Return power back to source and installation is now completed.
-
Read all WARNINGS before continuing this section.
-
Make sure POWER IS TURNED OFF at the source to the location at which you are installing the product.
-
Remove lens, cover and fluorescent tubes. Cut away all wires connecting the ballast. (fig. 1)
-
Follow wiring diagrams for number of lamps and original ballast type (instant start, programmed start or rapid start). (fig. 3-6)
-
Visibly affix the “Modification Sticker” to the fixture and reinstall housing cover and lens if applicable.
-
Return power back to the source and installation is complete.