BLUERIDGE BMKH18M23UH Split Type Wall Mounted Air Conditioner Owner’s Manual

June 5, 2024
BLUERIDGE

BLUERIDGE BMKH18M23UH Split Type Wall Mounted Air Conditioner Owner’s Manual
BLUERIDGE BMKH18M23UH Split Type Wall Mounted Air
Conditioner

Explanation of Symbols

DANGER: Indicates a hazardous situation that, if not avoided, will result in death or serious injury.

WARNING : Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

CAUTION: Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury.

NOTICE: Indicates important but not hazard-related information, used to indicate risk of property damage.

  Indicates a hazard that would be assigned a signal word WARNING or CAUTION.

Exception Clauses

Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.

  1. Damage to the product due to improper use or misuse of the product;
  2. Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer;
  3. After verification, the defect of product is directly caused by corrosive gas;
  4. After verification, defects are due to improper operation during transportation of product;
  5. Operate, repair, maintain the unit without abiding by instruction manual or related regulations;
  6. After verification, the problem or dispute is caused by the quality specification or performance of parts and components that produced by other manufacturers;
  7. The damage is caused by natural calamities, bad using environment or force majeure.

CONFORMITY AND RANGE

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.

Please read this owner’s manual carefully before operating the unit and keep it carefully for consultation.

 Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.
Instructions for installation and use of this product are provided by the manufacturer.

THE INSTRUCTIONS BEFORE USE

Warning

  • When having a burning smell or smoke, please turn off the  Power supply and contact with the service center.
    Safety Instruction

If the abnormity still exists, the unit may be damaged, and may cause electric shock or fire.

|

  • The power supply must adopt the special circuit that with air switch protection and assure it has enough capacity. The unit will be turned on or off according to your requirement automatically, please do not turn on or turn off the unit frequently, otherwise disadvantage effect may be caused to the unit.

|

  • Never cut off or damage power cables and control wires. If the power cable and signal control wire were damaged, change them by professional.

---|---|---

  • Power must adopts the special circuit to prevent fire.
    Safety Instruction

Otherwise, it can cause electric shock or fire.

|

  • Disconnect the power supply if long putting the air conditioner out of use.
    Safety Instruction

Otherwise, the accumulated dusts may cause overheating or fire.

|

  • Never damage the electric wire or use the electric wire which is not appointed.
    Safety Instruction

Otherwise, it will cause overheating or fire.

  • When cleaning, it is necessary to stop driving and turn off the power supply.
    Safety Instruction

Otherwise, it may cause electric shock or damage.

|

  • Rated voltage of this air conditioner 208/230V, 60Hz, The compressor will vibrate sharply if the voltage is too low, reappointed. image to refrigerating system. Electrical component are easy to damage if the voltage is too high.

|

  • Don’t attempt to repair the air conditioner by yourself.
    Safety Instruction

The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair.

  • Please note whether the installed stand is firm enough or not.
    Safety Instruction

If it is damaged, it may lead to the fall of the unit and cause the injury.

|

  •  Don’t step on the top of the outdoor unit or place something on it.
    Safety Instruction

As falling off the outdoor unit can be dangerous.

|

  •  Earthling: The unit must be reliably earthed. The earthling cable shall be connected to the special earthling device in the construction.

NAME OF PARTS

BMKH18M23UH

WARNING

  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
  • Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.
  • Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.
  • Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
  • Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
  • The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.

OUTDOOR UNIT

No.| Description
1| Air outlet grille
2| Valve

OUTDOOR UNIT
Note:
The above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

BMKH24M23UH

WARNING

  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
  • Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.
  • Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case
  • Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
  • Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
  • The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.

OUTDOOR UNIT

No.| Description
1| Air outlet grille
2| Valve

OUTDOOR UNIT
Note:
The above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

BMKH36M23UH , BMKH42M23UH WARNING

  • If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
  • Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.
  • Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case
  • Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (Only use soft dry cloth moist cloth clean the air conditioner cabinet).
  • Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
  • The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.

OUTDOOR UNIT

No.| Description
1| Air outlet grille
2| Valve

OUTDOOR UNIT
Note:
The above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

TECHNICAL DATA

MODE| BMKH18M23UH|
---|---|---
Electrical data
Electricity supply| 208/230V,60Hz| A
Fuse or air switch| 35| mm A A 2
Minimum power cord section 5.3

Electricity supply

| L| 36.22| In
P| 14.96| In
H| 31.10| In
MODE| BMKH24M23UH|
---|---|---
Electrical data
Electricity supply| 208/230V,60Hz| A
Fuse or air switch| 40| mm A A 2
Minimum power cord section 5.3

Electricity supply

| L| 36.22| In
P| 14.96| In
H| 31.10| In
MODE| BMKH24M23UH|
---|---|---
Electrical data
Electricity supply| 208/230V,60Hz| A
Fuse or air switch| 8.4| mm A A 2
Minimum power cord section 5.3

Electricity supply

| L| 40| In
P| 17.32| In
H| 43.42| In

OUTDOOR UNIT WORKING TEMPERATURE RANGE

  Outdoor side DB/WB( °F/ °C )
Maximum cooling 115°F (46°C)/-
Maximum heating 75.2°F (24°C)/-

ELECTRICAL CONNECTIONS

BMKH18M23UH

  1. Remove the handle at the right side plate of the outdoor unit (one screw).
  2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank. Wiring should meet that of indoor unit.
  3. Fix power connection wire by wire clamp.
  4. Ensure wire has been fixed well.
  5. Install the handle.

  Including an air switch with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit)

Air-conditioner Air switch capacity
BMKH18M23UH 35A

ELECTRICAL CONNECTIONS

  An all-pole disconnection switch having a contact separation of at least 0.11in in all pole should be connected in fixed wiring.

Wrong wire connection may cause malfunction of some electric components. After fixing cable, ensure that leads between connection to fixed point have some space.

The connection pipes and the connection wirings of the unit A and unit B must be corresponding to each other respective.

 The appliance shall be installed in accordance with national wiring regulations.

Note: The above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

  1. Remove the handle at the right side plate of the outdoor unit (one screw)
  2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank. Wiring should meet that of indoor unit.
  3. Fix power connection wire by wire clamp.
  4. Ensure wire has been fixed well.
  5. Install the handle.

Including an air switch with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit)

An all-pole disconnection switch having a contact separation of at least 0.11in in all pole should be connected in fixed wiring.

Wrong wire connection may cause malfunction of some electric components. After fixing cable, ensure that leads between connection to fixed point have some space.

The connection pipes and the connection wirings of the unit A, unit B, unit C and unit D must be corresponding to each other respective.

The appliance shall be installed in accordance with national wiring regulations.

Note: The above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

Air-conditioner Air switch capacity
BMKH24M23UH 40A

Air switch capacity

BMKH42M23UH

  1. Remove the handle at the right side plate of the outdoor unit (one screw).
  2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank. Wiring should meet that of indoor unit.
  3. Fix power connection wire by wire clamp.
  4. Ensure wire has been fixed well.
  5. Install the handle

Including an air switch with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit).

An all-pole disconnection switch having a contact separation of at least 0.11in in all pole should be connected in fixed wiring.

  Wrong wire connection may cause malfunction of some electric components. After fixing cable, ensure that leads between connection to fixed point have some space.

 The connection pipes and the connection wirings of the unit A, unit B, unit C and unit D, unit E must be corresponding to each other respective.

The appliance shall be installed in accordance with national wiring regulations.

Note: The above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased.

Air-conditioner Air switch capacity
BMKH36M23UH 60A

ELECTRICAL CONNECTIONS

INSTALLING THE OUTDOOR UNIT

Location

Use bolts to secure the unit to a flat, solid floor. When mounting the unit on a wall or the roof, make sure the support is firmly secured so that it cannot move in the event of intense vibrations or a strong wind.

Do not install the outdoor unit in pits or air vents.

Installing the pipes

Use suitable connecting pipes and equipment for the refrigerant R410A.

Models(ft) 18Kx2 24Kx2 24Kx3 36Kx2 36Kx3
Max. connection pipe length 164.04 164.04 229.66 164.04 246.06
Max. connection pipe length (Simple one indoor unit) 82.02 82.02 82.02
82.02 82.02
Models(ft) 36Kx4 42Kx2 42Kx3 42Kx4 42Kx5
Max. connection pipe length 246.06 164.04 246.06 262.47 262.47
Max. connection pipe length (Simple one indoor unit) 82.02 82.02 82.02
82.02 82.02

The refrigerant pipes must not exceed the maximum heights 10m(18Kx2&24Kx2&24Kx3&36×2&36×3&36 x4&42×2&42×3&42×4&42×5).

Wrap all the refrigerant pipes and joints

Tighten the connections using two wrenches working in opposite directions.

Caution: Installation Must be Performed in Accordance with the NEC/CEC by Authorized Personnel Only.
Install the drain fitting and the drain hose (for model with heat pump only)

Condensation is produced and flows from the outdoor unit when the appliance is operating in the heating mode. In order not to disturb neigh bourse and to respect the environment, install a drain fitting and a drain hose to channel the condensate water.
Install the drain fitting and rubber washer on the outdoor unit chassis and connect a drain hose to it as shown in the figure.
Installation

BLEEDING INSTALLER

Humid air left inside the refrigerant circuit can cause compressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the
refrigerant circuit using a vacuum pump.

  1. Unscrew and remove the caps from the 2-way and 3 way valves.
  2. Unscrew and remove the cap from the service valve.
  3. Connect the vacuum pump hose to the service valve.
  4. Operate the vacuum pump for 10-15 minutes until an low-pressure knob on the vacuum pump coupling.
  5. With the vacuum pump still in operation, close the low-pressure knob on the vacuum pump coupling. Stop the vacuum pump.
  6. Open the 2-way valve by 1/4 turn and then close it after 10 seconds. Check all the joints for leaks using liquid soap or an electronic leak device.
  7. Turn the body of the 2-way and 3-way valves. Disconnect the vacuum pump hose.
  8. Replace and tighten all the caps on the valves.
Diameter Twisting moment (N.m)
1/4” 15-20
3/8” 35-40
5/8” 60-65
1/2” 45-50
3/4” 70-75

18、24、36、42K unit need to be installed the indoor unit
conversion joint
Bleeding Installer
INDOOR UNIT

MAINTENANCE

Use suitable instruments for the refrigerant R410A.
Do not use any other refrigerant than R410A.
Do not use mineral oils to clean the unit.
Maintenance

INSTALLATION DIMENSION DIAGRAM

The installation must be done by trained and qualified service personnel with reliability according to this manual.
Contact service center before installation to avoid the malfunction due to unprofessional installation.
When picking up and moving the units, you must be guided by trained and qualified person.
Ensure that the recommended space is left around the appliance.

BMKH18M23UH
Installation Dimension Diagram

BMKH24M23UH
Installation Dimension Diagram

BMKH36M23UH , BMKH42M23UH
Installation Dimension Diagram

CHECK AFTER INSTALLATION

Check Items Problems Owing to Improper Installation
Is the installation reliable? The unit may drop, vibrate or make noises
Has the gas leakage been checked? May cause unsatisfactory cooling (heating)

effect
Is the thermal insulation of the unit sufficient?| May cause condensation and water dropping
Is the drainage smooth?| May cause condensation and water dropping
Does the power supply voltage accord with the rated voltage specified on the nameplate?| The unit may break down or the components may be burned out
Are the lines and pipelines correctly installed?| The unit may break down or the components may be burned out
Has the unit been safely grounded?| Risk of electrical leakage
Are the models of lines in conformity with requirements?| The unit may break down or the components may be burned out
Are there any obstacles near the air inlet and outlet of the indoor and out- door units?| The unit may break down or the components may be burned out
Have the length of refrigerating pipe and refrigerant charge amount been recorded?| It is not easy to decide the charge amount of refrigerant.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BLUERIDGE User Manuals

Related Manuals