BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted Ductless Indoor Air Handler Owner’s Manual

June 13, 2024
BLUERIDGE

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted

Ductless Indoor Air Handler

Product Information

Owner’s Manual

Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.

Table of Contents

  1. Remote Controller Specifications
  2. Quick Start Guide
  3. Handling the Remote Controller
  4. Buttons and Functions

Remote Controller Specifications

The remote controller is compatible with the following air conditioner models:

  • RG10L(G2HS)/BGEF
  • RG10L(G2HS)/BGEFU1
  • RG10L1(G2HS)/BGEF
  • RG10L1(G2HS)/BGEFU1
  • RG10L10(G2HS)/BGEF
  • RG10P(G2HS)/BGEF
  • RG10P(G2HS)/BGEFU1
  • RG10P1(G2HS)/BGEF
  • RG10L(D2HS)/BGEF
  • RG10L(D2HS)/BGEFU1
  • RG10L1(D2HS)/BGEF
  • RG10L1(D2HS)/BGEFU1
  • RG10P1(G2HS)/BGEFU1
  • RG10L10(D2HS)/BGEF

Quick Start Guide

  1. FIT BATTERIES

  2. AUTO COOL DRY HEAT FAN SELECT MODE

  3. SELECT TEMPERATURE

  4. PRESS POWER BUTTON

  5. Swing

  6. My Mode Fo Mode HEDARCTYOAOULTO SET TEMPERATURE LOMWEHDIGFAHN
    On/Off Fan Sleep

  7. POINT REMOTE TOWARD UNIT

  8. SELECT FAN SPEED

Handling the Remote Controller

Inserting and Replacing Batteries

Your air conditioning unit may come with two batteries (some units). Follow these steps to insert or replace the batteries:

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

BATTERY NOTES:

  • Replace the batteries if you don’t plan on using the device for more than 2 months.
  • Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
  • Do not use batteries that have been used for more than 2 months.

NOTES FOR USING REMOTE CONTROL:

FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference.

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.

  • ON/OFF: Turns the unit on or off.

  • SET: Scrolls through operation functions.
    Press the OK button to confirm the selected symbol.

  • TEMP: Decreases temperature in 0.5°C (1°F) increments. Minimum temperature is 16°C (60°F).

  • FAN SPEED: Selects fan speeds. Press the TEMP or button to increase/decrease the fan speed in 1% increments.

  • SWING: Starts and stops the horizontal louver movement. Hold down for 2 seconds to initiate vertical louver auto swing feature.

  • MODE: Scrolls through operation modes: AUTO, COOL, DRY, HEAT, FAN. Note that HEAT mode is not supported by the cooling only appliance.

  • Eco Intelligent eye: Used to detect people’s activities in the room to save energy.

IMPORTANT NOTE:
Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.

Remote Controller Specifications

model| RG10L(G2HS)/BGEF, RG10L(G2HS)/BGEFU1, RG10L1(G2HS)/BGEF, RG10L1(G2HS)/BGEFU1, RG10L10(G2HS)/BGEF,RG10P(G2HS)/BGEF, RG10P(G2HS)/BGEFU1, RG10P1(G2HS)/BGEF, RG10L(D2HS)/BGEF, RG10L(D2HS)/BGEFU1, RG10L1(D2HS)/BGEF, RG10L1(D2HS)/BGEFU1,

RG10P1(G2HS)/BGEFU1,RG10L10(D2HS)/BGEF

---|---
Reted voltage| 3.0V( Dry batteries R03/LR03×2)
Signal Receiving Range| 8m
Enviroment| -5°C~60°C(23°F~140°F)

Quick Start Guide

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig1

NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.

SPECIAL NOTE

  • Button designs on your unit may differ slightly from the example shown.
  • If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
  • When there are wide differentces between “Remote controller Manual” and “USER’S
  • MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.

Handling the Remote Controller

Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the batteries in the remote control before use.

  1. Slide the back cover from the remote control downward, exposing the battery compartment.
  2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
  3. Slide the battery cover back into place.

BATTERY NOTES

For optimum product performance:

  • Do not mix old and new batteries, or batteries of different types.
  • Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.

BATTERY DISPOSAL

Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.

TIPS FOR USING REMOTE CONTROL

  • The remote control must be used within 8 meters of the unit.
  • The unit will beep when remote signal is received.
  • Curtains, other materials and direct sunlight can interfere with the infrared signal receiver. Remove batteries if the remote will not be used more than 2 months.

NOTES FOR USING REMOTE CONTROL

The device could comply with the local national regulations.

  • In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
  • In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.

Buttons and Functions

Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig3

Model:

RG10L(G2HS)/BGEF and RG10L(G2HS)/BGEFU1(Fresh feature is not available)
RG10L1(G2HS)/BGEF,RG10L1(G2HS)/BGEFU1
RG10L10(G2HS)/BGEF(20-28 C/68-82 F)

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig4

Model:

RG10P(G2HS)/BGEF and RG10P(G2HS)/BGEFU1(Fresh feature is not available) RG10P1(G2HS)/BGEF,RG10P1(G2HS)/BGEFU1

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig5 Model:
RG10L(D2HS)/BGEF and RG10L(D2HS)/BGEFU1(Fresh feature is not available)
RG10L1(D2HS)/BGEF,RG10L1(D2HS)/BGEFU1
RG10L10(D2HS)/BGEF(20-28 C/68-82 F)

Remote Screen Indicators

Information are displayed when the remote controller is power up.

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig6

Note:
All indicators shown in the figure are for the purpose of clear presentation. But during the actaul operation, only the relative function signs are shown on the display window.

How to Use Basic Functions

ATTENTION Before operation, please ensure the unit is plugged in and power is available.

AUTO Mode

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig7

NOTE:

  1. In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature.
  2. In AUTO mode, fan speed can not be set.

COOL or HEAT Mode

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig8

DRY Mode

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig9

NOTE: In DRY mode, fan speed can not be set since it has already been automatically controlled.

FAN Mode

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig10

NOTE: In FAN mode, you can’t set the temperature. As a result , no temperature displays in remote screen.

Setting the TIMER

TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.

TIMER ON setting

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig11

TIMER OFF setting

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig12

NOTE:

  1. When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
  2. Cancel either function by setting its timer to 0.0h.

TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours after the current time.

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig13

How to Use Advanced Functions

Swing function

Press Swing button

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig14

Airflow direction

If continue to press the SWING button, five different airflow directions can be set. The louver can be move at a certain range each time you press the button. Press the button until the direction you prefer is reached(some u nits only).

LED DISPLAY

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig16

ECO/GEAR function

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig17

ECO operation:
Under cooling mode, press this button, the remote controller will adjust the temperature Oautomatically to 24 C/75 F, fan speed of Auto to save energy (only when the set temperature Ois less than 24 C/75 F). If the set temperature is above 24 C/75 F, press the ECO button,O O the fan speed will change to Auto, the set temperature will remain unchanged.

NOTE:
Pressing the ECO button, or modifying the mode or adjusting the set temperature to less Othan 24 C/75 F will stop ECO operation.
Under ECO operation, the set tmeperature should be 24 C/75 F or above, it may result inO O insufficient cooling. If you feel uncomfortable, just press the ECO button again to stop it.

GEAR operation:
Press the ECO/GEAR button to enter the GEAR operation as following:
75%(up to 75% electrial energy consumption)
50%(up to 50% electrial energy consumption)
Previous setting mode.
Under GEAR operation, the display on the remote controller will alternage between electical energy consumption and set temperature.

ECO Intelligent Eye Function(For models of RG10L series)

Press this button

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig18

Silence function

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig19

FP function

Press this button 2 times during one second under HEAT Mode and setting temperature of O O16 C/60 F or 20 C/68 F(for models O RG10L10(G2HS)/BGEF & RG10L10(D2HS)/BGEF only).

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig20

Note: This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting temperature of 16 C/60 F or 20 C/68 F(for model RG10L10(G2HS)/BGEF& RG10L10(D2HS)/BGEF) to
activate FP function.Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel this function.

LOCK function

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig21

Turbo Function

Press Turbo button

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig22

Intelligent Eye Function(For models of RG10P series)

Press this button

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig23

SET function

BLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall Mounted
Ductless Indoor Air Handler-fig24

  • Press the SET button to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm.
  • To cancel the selected function, just perform the same procedures as above.
  • Press the SET button to scroll through operation functions as follows:
    Breeze awayBLUERIDGE BMY33HH20WM 33,000 BTU Single Zone Hyper Heat Wall
Mounted Ductless Indoor Air Handler-fig26 AP mode ( ) Breeze away…. [* ]: Model dependent

Breeze Away function( ) (some units) :
This feature avoids direct air flow blowing on the body and makes you feel indulging in silky coolness.
NTOE: This feature is available under cool, Fan and Dry mode only.

Active clean function( ) (some units) :
The Active Clean Technology washes away dust, mold, and grease that may cause odors when it adheres to the heat exchanger by automatically freezing and then rapidly thawing the frost. When this function is turned on, the indoor unit display window appears “CL”, after 20 to 45 minutes, the unit will turn off automatically and cancel CLEAN function.

Self clean function (some units) :
Airborne bacteria can grow in the moisture that condenses around heat exchanger in the unit. With regular use, most of this moisture is evaporated from the unit. Under Self clean operation, the unit unit will clean itself automatically. After cleaning, the unit will turn off automatically.
Note: You can only activate this function in COOL or DRY mode.

FRESH function( ) (some units) :
When the FRESH function is initiated, the Ionizer/Plasma Dust Collector(depending.
on models) is energized and will help to remove pollen and impurities from the air

Sleep function( ) :
The SLEEP function is used to decrease energy use while you sleep (and don ,t need the same temperature settings to stay comfortable). This function can only be activated via remote control.
For the detail, see sleep operation in USER S MANUAL. ,
Note: The SLEEP function is not available in FAN or DRY mode.

Follow me function( ) :
The FOLLOW ME function enables the remote control to measure the temperature at its current location and send this signal to the air conditioner every 3 minutes interval. When using AUTO, COOL or HEAT modes, measuring ambient temperature from the remote control(instead of from the indoor unit itself) will enable the air conditioner to optimize the temperature around you and ensure maximum comfort.

NOTE: Press and hold Turbo button for seven seconds to start/stop memory feature of Follow Me function.

  • If the memory feature is activated, ,,On displays for 3 seconds on the screen.
  • If the memory feature is stopped, ,,OF displays for 3 seconds on the screen.
  • While the memory feature is activated, press the ON/OFF button, shift the mode or power failure will not cancel the Follow me function.

AP function( )(some units) :
Choose AP mode to do wireless network configuration. For some units, it doesn’t work by pressing the SET button. To enter the AP mode, continuously press the LED button seven times in 10 seconds.

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

AlpineHomeAir.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BLUERIDGE User Manuals

Related Manuals