MICRODAM MDV600 Prime Digital Vacuum Cleaner User Guide

June 5, 2024
MICRODAM

MICRODAM MDV600 Prime Digital Vacuum Cleaner

Special features

  1. A compact size
  2. Vac-Lock valve to protect vacuum sensor
  3. Bluetooth connection with smartphone
  4. Target vacuum and alarm
  5. Unit if measure: Micron/Torr/mbar/Pa
  6. Back-light display
  7. Power supply: AAA battery x 2

Display

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig2

Control Buttons

  • :Power
  • LCD backlight on/off & bluetooth
  • Set Target Vacuum
  • :Unit of measure & Auto-off

Specification

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig17

Button configuration

Power Power

  1. Press for 2 seconds
  2. All signs on
  3. Measurement standby Screen

Unit of measurement & auto-off setting

  1. Measurement standby screen
  2. Press for 3 seconds Unit display blinks
  3. Short press Unit display change

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig8

  1. Press for 3 seconds Auto-Off Display blinks
  2. Short press Auto-Off on/off change
  3. Press for 3 seconds Measurement standby screen

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig9

Set target vacuum

  1. Measurement standby screen
    When target off, target vacuum display is turned off Target vacuum value according to vacuum unit

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig10

  1. Press for 3 seconds
  2. Short press
  3. Press for 3 seconds
    target vacuum display blinks
    Change the target vacuum value

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig11

Backlight & Bluetooth

Backlight:Short press on/off
Bluetooth: Press and hold (about 3 seconds) on/off
(When the power is tuned on, the Bluetooth connection standby status is automatically maintained for about 3 minutes.)

  1. Measurement standby Screen
  2. Bluetooth connection
  3. Bluetooth off if not Connected tor 3 minutes

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig13

Precautions for vacuum work

The vacuum sensor built into this device may malfunction if it is frequently exposed to oil and foreign substances. When working, please pay attention to the following points.

  1. Lock the vacuum lock valve located on the right side of the product and operate the vacuum pump.
  2. Remove any foreign substances from the pipe while locking the vacuum lock valve for 1/3 or 1/2 of the average vacuum pump operation time, and open the vacuum lock valve to check the vacuum level.
  3. When the target value is reached, start the vacuum test.
  4. Lock the vacuum locking valve on the right side of the instrument after completing the vacuum operation. (Prevent foreign substances from entering the vacuum sensor)
  5. Power off the vacuum pump.
Recommendation
  1. The gauge can be used vertically using the hook on the back. (Do not use the device on the floor.)
  2. We recommend a vacuum pump with a backflow prevention function.
  3. The oil in the vacuum pump is changed periodically.
  4. Keep the refrigerant hose clean and check frequently to see if the joints of the hose are loose.

Emergency measures when the vacuum sensor is contaminated with oil

  1. Open the black vacuum lock valve located on the right side of the instrument.
  2. Connect the vacuum pump to the left (or right) of the t-type connector.
  3. Run the vacuum pump for about 2~3 minutes to remove the oil inside.
  4. If the oil does not drain sufficiently, increase the time for step 3 and repeat.
  5. Check if the vacuum value of the device is displayed properly.
How to use Bluetooth

Connection to the smartphone
This equipment can be connected to the smartphone which makes the measured value checked, saved and sent to the outside. For this, you need to install an application (the app) on your smartphone.(Android smartphone: Google Play Store, Apple iPhone: App Store)

Installation of smartphone application (app)
Install the MICRODAM MDi app on Google Play Store of the Android phone and App Store of Apple iPhone (Store search term

Connection of manifold gauge to the smartphone

Prepare for the Bluetooth connection by pressing the button on the manifold gauge.

  1. If you press the button for about 3 seconds, the Bluetooth mark on the top of the LCD blinks, making the equipment ready to be connected to the smartphone.
  2. When the equipment is connected to a smartphone,the Bluetooth mark stops blinking.

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig17

  1. Turn on the Bluetooth function of the smartphone.
  2. Implement the MICRODAM MDI app on your smartphone.
  3. Connecting the manifold gauge to the smartphone,
  4. When you implement the app, the list of manitold gauges that can be Connected automatically is displayed on the screen in green.
  5. Touch the manifold gauge marked in green on the device list, and then the manifold gauge will be connected to the app.

MICRODAM MDV600 Prime Digital Vacuum Cleaner-fig16

FCC STATEMENT :

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2.  This device must accept any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

RF warning statement:
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals