FOAMit SP-5NV 5 Gallon Air Operated Portable Spray Equipment User Manual

June 5, 2024
FOAMit

FOAMit SP-5NV 5 Gallon Air Operated Portable Spray Equipment

FOAMit-SP-5NV-5-Gallon-Air-Operated-Portable-Spray-Equipment-
product

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

WARNING

Read this manual completely and understand the machine before operating or servicing it.

  • Read all instructions before installing or operating the unit.
  • Always wear appropriate personal protective equipment (PPE) when operating or servicing the unit.
  • Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS).
  • Never point the discharge trigger gun at yourself,another person, or any object you do not want covered in chemical.
  • Always depressurize the unit after use (as described in the After Use Instructions), and store the unit depressurized.
  • Do not exceed an incoming air pressure of 100 psi (7 bar).
  • Do not exceed a fluid temperature of 100˚F (37˚C).
  • Only use clean and dry air. Air must be filtered and free of moisture or pump life will be diminished. If needed, install an air dryer before the unit.
  • Do not use an air lubricator before the unit.

Specifications

  • Hose ………….. 30 feet reinforced hose, 3/8 inch inside diameter
  • (9 meters reinforced hose, 9.5 mm inside diameter)
  • Tank Capacity………………………………………….. 5 gallons (20 liters)
  • Spray Output………………….. 2 gallons/minute (7.5 liters/minute)
  • Spray Output Distance………………… 10 to 12 feet (3 to 4 meters)
  • Liquid Temperature …………………… 40˚F to 100˚F (4.4˚C to 37˚C)

Dimensions

  • Length ………………………………… 25 in (635 mm) approximately
  • Width …………………………………. 14 in (356 mm) approximately
  • Height ………………………………… 22 in (559 mm) approximately
  • Weight, including discharge hose and wand:
    • (Empty) ………………………….. 31 lbs (14 kg) approximately

Requirements

  • Compressed Air Source Requirements: Air regulator (R25) is factory set at 50 psi (3.4 bar).
  • The operating range is 40 to 80 PSI (3 to 5 bar) with 2 CFM (56.6 l/min).
  • Chemical Requirements: Follow all instructions from the chemical manufacturer and Safety Data Sheet (SDS).
Air Operated Double Diaphragm Pump Models Offered
  • P56: Polypropylene body with Santoprene diaphragm
  • P56V: Polypropylene body with Viton diaphragm
  • P56K: Polypropylene body with Kalrez diaphragm

Acceptable Products

  • Alkaline cleaners, Caustic cleaners, Sanitizers, and Acids
  • D-Limonene may only be used with the Kalrez pump
  • Chlorine may only be used with Viton or Kalrez pump
  • DO NOT USE: All hydrocarbons

Operation Instructions

Wearing all PPE and observing all safety precautions dictated by the MSDS for your chemical:

  1. Fill the tank with the solution to be sprayed.
  2. Connect an appropriate compressed air line into the air inlet fitting (AP25).
  3. Squeeze the discharge trigger gun (PSG12) to begin spraying.

After Use Instructions

  1. Flush the unit with fresh water for 5 minutes.
  2. Disconnect the air line from the air fitting (AP25) and relieve any pressure remaining in the system by squeezing the discharge trigger gun (PSG12).
  3. Release the discharge trigger gun (PSG12) after all pressure has been relieved from the system.

Maintenance Instructions

To keep your portable unit operating properly, periodically perform the following maintenance procedures:

  • Check the air pump (P56/P56K/P56V) for wear and leaks.
  • Inspect hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured.
  • Replace filter (AFR25) in regulator (R25) as needed.
  • Check the suction tube and screen for debris and clean as needed.
  • Drain compressor tank on a regular basis to ensure proper operation of pump.

Troubleshooting Instructions

  • Check to ensure that the discharge hose is uncoiled properly and that there are no kinks that could obstruct fluid flow.
  • Check the air regulator bowl (ABR25) and air filter (AFR25) for debris such as water, oil, or dust particles. Clean by unthreading the air regulator bowl (ABR25) from the air regulator (R25).
  • Check the strainer (STR38-IL) for debris or other blockages, and clean as needed. Replace strainer if damaged. A strainer must be used.
  • If air passes through the pump (P56/P56K/P56V) without cycling, the pump needs to be replaced.
  • Check for proper air pressure on the air gauge (AG100).
  • The air regulator (R25) is factory set at 50 psi (3.4 bar).
  • The operating range is 40 to 80 PSI (3 to 5 bar) with 2 CFM (56.6 l/min).

If the unit operates at a reduced pressure

  • Check the air compressor supplying the unit. If the pressure is less than 40 psi, turn the unit off until the compressor can catch up.
  • If the air supply is 50 psi (3.4 bar) or above, check the air gauge (AG100), which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust the pressure by turning the knob on the top of the air regulator (R25).

TANK ASSEMBLY

  • ITEM NUMBER: TANK-5N-AFOAMit-SP-5NV-5-Gallon-Air-Operated-Portable-Spray-Equipment-fig-1

SPRAY GUN ASSEMBLY

  • ITEM NUMBER: SGA14

DISCHARGE HOSE ASSEMBLY

  • ITEM NUMBER: H38-30

BACKPLATE

Inside View

FOAMit-SP-5NV-5-Gallon-Air-Operated-Portable-Spray-Equipment-
fig-4

Outside View

FOAMit-SP-5NV-5-Gallon-Air-Operated-Portable-Spray-Equipment-
fig-5

OPTIONAL COMPONENTS

WATER SEPARATOR
  • ITEM NUMBER: WS-20CFM

AIR HOSE ASSEMBLY

  • ITEM NUMBER: AH30
ITEM NUMBER DESCRIPTION
AG100 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE
AH30 30 ft Air Hose w/ Quick Connect Fittings
AP25 PLUG 1/4 NPTM AIR FITTING – BRASS
BPS-58SO Back Panel Screw – 5/8 inch with Stand Off
BPS-SSR 1/4 INCH PUSHNUT BOLT RETAINER STAINLESS

STEEL

CST5-WHL| 4 INCH REPLACEMENT WHEEL FOR CST5SS AND

CST5SS-L

EC14-2| OETIKER CLAMP 13.8
F38SS| STAINLESS 3/8 INCH FERRULE
FWAX15| FLAT AXLE WASHER
FWP12| 7/8 ID X 1.5 OD X 0.05 THK SSFW
H14B-H| 1/4 INCH BLUE HOSE – Available per ft
H38B-H| 3/8 INCH BLUE HOSE – Available per ft
HBSS1238| STAINLESS HOSE BARB 1/2mpt X 3/8 barb Tariff

8479.90.9496

HBSSEL1814| 304 STAINLESS ELBOW 1/8 INCH NPT X 1/4 INCH

HOSE BARB

JC35B| BLACK 3.5 INCH ONE WAY VENTED CAP POLYPROPYLENE WITH GASKET AND CHECK VALVE
P14| COUNTERSUNK PLUG-HEXAGON 1/4
P56| 5700 PUMP WITH SANTOPRENE SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
P56K| 5700 PUMP WITH KALREZ SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
P56V| 5700 PUMP WITH VITON SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
P56-BRKT| PUMP BRACKET- STAINLESS STEEL
P56-BRKT-SCREW| HI LO SCREW FOR RETAINING P56-BRKT
PLPF| PORTABLE FOAMER BACK PLATE W/ HINGE AND

HOLES

PLPF-PIN| 302 STAINLESS PORTABLE PLATE HINGE PIN
PSG12| Assembly with o-rings included/1/2in POLY SPRAY GUN W/ GRAY HNDL. & 316SS
PSGORV| PSG12 VITON O RING
PW124-120| 1/2in BLACK POLY PRO X 4in – SCH.120 – 1/2in MPTOE & 1/4in FPTOE
R25| AIR REGULATOR – SILVER COLOR – 1/4fpt TWO PORT 1/8fpt TWO PORT – INCLUDES FILTER AND BOWL
AFR25| AIR FILTER for R25
ABR25| METAL AIR BOWL for R25
S142058-VS| 1/4-20 X 5/8 PHIL TRUSS MACHINE SCREW 18-8 W/#516 VIBRASEAL ORANGE PATCH
SC1212| S.S. COUPLER 1/2in BY 1/2in
SSA14| SS304 MALE/FEMALE ADAPTOR 1/4 NPT X 1/4 NPT
SSC38| WORM GEAR CLAMP, S/S (.25-.63)
---|---
SS-TAB| STAINLESS STEEL TAB 5/8 x 3/4 WITH 1/4 INCH MOUNTING HOLE
STR38-IL| IN LINE STRAINER 3/8 BARB 20 MESH 304 STAINLESS EDPM GSKT
TANK-5N| 5 GALLON ROTO MOLDED TANK WITH HANDLE
TANK-5N-HNDL| HANDLE FOR TANK-5N
TW916| 1/2 INT TOOTH L/W 410SS
WS-20CFM| TSUNAMI WATER SEPARATOR 20 CFM