AUSTRALIAN MONITOR ZMPS Zoning Paging Station Instruction Manual
- June 5, 2024
- Australian Monitor
Table of Contents
AUSTRALIAN MONITOR ZMPS Zoning Paging Station
IMPORTANT SAFETY INFORMATION
-
READ these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with dry cloth.
-
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety.
If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. -
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
-
Only use attachments/accessories specified by the manufacturer.
-
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
-
This appliance shall not be exposed to dripping or splashing water and that no object filled with liquid such as vases shall be placed on the apparatus.
-
Plug this apparatus to the proper wall outlet and make the plug to be disconnected readily operable.
-
Mains plug is used as a disconnected device and it should remain readily operable during intended use. In order to disconnect the apparatus from the mains completely, the mains plug should be disconnected from the mains socket outlet completely.
-
WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
-
An appliance with a protective earth terminal should be connected to a mains outlet with a protective earth connection.
-
The apparatus should be disconnected from the mains completely before speaker wiring. The speaker output should be proper protected from direct contact and pay attention to speaker connections, terminals and speaker wiring during normal operation.
Introduction
The Australian Monitor ZONE MIX Paging Station (ZMPS) is a software configurable paging station with a supercardioid gooseneck microphone. The ZMPS is designed to be used with the ZONEMIX system to provide paging and pre- recorded message playback to individual zones, a combination of zones or all zones. Connection to the ZONE MIX is via low cost CAT 5 cable. Ample label space is provided on the ZMPS for easy operation and LED indicators provide the user with visual feedback of the zones being paged or if the system is busy. A rear panel gain control allows level adjustment along with an internal audio limiter to guarantee voice clarity.
WARNING
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH AN EXTENSION
CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO
PREVENT BLADE EXPOSURE.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE
TO RAIN OR MOISTURE.
TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT & FULLY
INSERT.
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN
THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO
SO.
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
WARNING
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
For European Union countries: This symbol on
the product or its packaging indicates that this product must not be disposed
of with other waste. Instead, it is your responsibility to dispose of your
waste equipment by handing it over to a designated collection point for the
recycling of waste electrical and electronic equipment.
Please contact your local authority for further details of your nearest
designated collection point.
CONTROLS
-
SOFTWARE-DEFINED BUTTON
There are 13 software configurable buttons on the ZMPS. Each button can be configured to select a single zone, groups of zones or to activate a pre- recorded announcement. Use the ZONEMIX PC control software to assign the required function to each button. -
CLEAR
This button clears all selected zones -
ALL PAGE
This button pages to all zones. It is momentary so must be held while talking into the microphone. It activates the microphone and mutes or ducks the program sources (depending on configuration).
It does NOT clear the current zone selection configuration so the paging station will return to its previous state (selected zones) once the ALL PAGE button is released. -
ZONE PAGE
This button pages to the currently selected zone/s as indicated by their respective LEDs. The zones being paged have their program sources muted or ducked (depending on configuration) and the microphone becomes active. -
CHIME
The chime LED will turn on to indicate the pre-announce chime is playing. Do not speak through the ZMPS until this LED is off. -
BUSY
The busy LED will turn on when the system is busy performing another page. This can be caused by the local paging station (you are making a page) or a remote paging station being in use.
Paging and messaging are not possible while the system is busy, however zone selections can still be made. -
GAIN
To accommodate different speech levels, there is a gain control on rear of the ZMPS. Adjust the level to provide clear paging audio. -
ACCESSORY PORT
Connect the ZMPS to the ZONEMIX accessory ports using Cat5, Cat5e or Cat6 cable. -
PORT TERMINATION SWITCHES
Turn both switches ON (Up) if the ZMPS is the last device on an accessory cable run.
NOTE: Turn off the ZONE MIX when making wiring or termination changes.
CONNECTING THE ZMPS
- ZMPS WIRING
Wire the ZMPS paging station as per the images below.
Category 5, 5e and 6 cabling are supported.
T-568A wiring is recommended. However, T-568B is also supported.
Pin | Colour | Signal |
---|---|---|
1 | Green/White | Paging Audio + |
2 | Green | Paging Audio – |
3 | Orange/White | RS485 B |
4 | Blue | +24V DC |
5 | Blue/White | GND |
6 | Orange | RS485 A |
7 | Brown/White | Local Input + |
8 | Brown | Local Input – |
-
DAISY CHAINING ZMPS STATIONS
If you need to daisy chain ZMPS paging stations on the same accessory port run, use a terminal block or RJ45 splitter as shown. (Not included) -
ZMPS TERMINATION (DO NOT SKIP THIS STEP)
If the ZMPS is the LAST device on an accessory port cable run it MUST be terminated using the rear panel “PORT TERM” DIP switches by turning them to the ON position.
If the ZMPS is NOT the LAST device on the accessory port cable run the “PORT TERM” switches must be OFF.
The ZONE MIX system uses the RS485 standard to communicate with the paging stations. RS485 requires that each end of a cable run is terminated to prevent signal corruption due to signal reflections in the cable. -
POWER ON THE ZONEMIX4/8
Once the paging stations have been correctly wired and connected to the ZONE MIX via the accessory ports, power on the ZONEMIX4/8.
The ZMPS paging station with than flash all LEDs every second.
This indicates that the ZMPS is waiting to be PAIRED with the ZONE MIX using the PC control software. -
P AIRING AND CONFIGURATION Pairing and configuring the ZMPS is performed using the ZONEMIX control software available on the Australian monitor website: www.australianmonitor.com.au
Please consult the ZONEMIX4/8 manual for detailed instructions on pairing ZMPS stations and configuring the button functions. -
ZMPS INSTALLATION AND OPERATION MANUAL
SPECIFICATIONS
MICROPHONE|
---|---
LENGTH| 600mm
TRANSDUCER TYPE| Dynamic
POLAR PATTERN| Supercardoid
FREQUENCY RESPONSE| 100Hz – 15kHz
CONTROLS / STATUS|
13 PROGRAMMABLE BUTTONS| Programmable via ZONEMIX control software
ALL PAGE, ZONE PAGE, CLEAR BUTTONS|
PORT TERM| DIP switches for RS485 bus termination
LED INDICATORS
| Green LED on programmable buttons and Chime
Red LED on Busy
CONNECTION|
RJ45 FOR POWER, AUDIO, AND COMMS| Supports UTP Cat5, Cat5e, and Cat6
POWER|
DC INPUT (Via RJ45)| 24V DC, 45mA
MISCELLANEOUS|
PRODUCT DIMENSIONS| 132mm x 173.9mm x 350mm (5.2”W x 6.9”D x 13.8”H)
SHIPPING DIMENSIONS| 350mm x 200mm x 145mm x (13.8”W x 7.9”D x 5.7”H)
NET WEIGHT| 1.0kg
SHIPPING WEIGHT| 1.5kg
OPERATING TEMPERATURE| 0°C to 40°C
FINISH| Powder coated steel
COLOUR| Black (Satin)
ACCESSORIES
| Label sticker sheet
Microphone Windsock
APPROVALS| CE, IEC, RCM
**Microphone Frequency Response
ZMPS DRAWINGS**
ENGINEERED BY AUSTRALIAN MONITOR
Address: Unit 1, 2 Daydream Street, Warriewood NSW 2102 Australia
Website: www.australianmonitor.com.au
International inquiries email:
international@australianmonitor.com.au
ABN 86 003 231 187
References
- Australian Monitor - Commercial and pro audio product manufacturer
- Australian Monitor - Commercial and pro audio product manufacturer