The ZONE MIX accessory ports allow for the connection of wall panels, paging stations and audio input sources. Please follow the guide below to set up your system.

Australian Monitor ZONEMIX Wiring GuideAustralian Monitor ZONEMIX Wiring Guide -
fig1Australian Monitor ZONEMIX Wiring Guide -
fig2Australian Monitor ZONEMIX Wiring Guide -
fig3Australian Monitor ZONEMIX Wiring Guide -
fig4

**** Please note that accessory port local audio input channels are locked to the corresponding output zone and only one can be used per zone. E.g. Accessory port 1 local input connects to Zone 1. However, multiple wall panels and paging stations can be connected on the same accessory port.

STEP 1: DECIDE PORT WIRING LAYOUT

Australian Monitor ZONEMIX Wiring Guide - fig5

STEP 2: CONFIRM YOU DO NOT EXCEED THE FOLLOWING LIMITS

Maximum cable length per port| Accessories per port| Maximum Accessories in the system
---|---|---
100m| 8| 24
130m| 7
180m| 6
250m| 5
400m| 4
500m| 3

The maximum distances quoted in the table are due to DC’s current limitations.
The paging stations and wall panels can be locally powered to increase the cable length to a maximum of 500m. Please read the following additional document: Advanced accessory port wiring guide.

STEP 3: ACCESSORY PORT WIRING

Wire the ZONE MIX and ZMPS paging stations as per the images below.

  • Category 5, 5e, and 6 cablings supported.
  • T-568A wiring is recommended. However, T-568B is also supported.

ZONEMIX AND ZMPS WIRING

Australian Monitor ZONEMIX Wiring Guide - fig6

Pin Colour Signal
1 Green/White Paging Audio +
2 Green Paging Audio –
3 Orange/White RS485 B
4 Blue +24V DC
5 Blue/White GND
6 Orange RS485 A
7 Brown/White Local Input +
8 Brown Local Input –

ZMPS DAISY CHAIN WIRING

Australian Monitor ZONEMIX Wiring Guide - fig8

STEP 3: ACCESSORY PORT WIRING (CONT.)

Wire the wall panels as per the images below.

  • Category 5, 5e, and 6 cablings supported.
  • T-568A wiring is recommended. However, T-568B is also supported.

Australian Monitor ZONEMIX Wiring Guide - fig9Australian Monitor ZONEMIX Wiring Guide -
fig10

STEP 4: PORT TERMINATION – DO NOT SKIP THIS STEP

The ZONE MIX uses the RS485 standard to communicate to wall panels and paging stations. RS485 requires that each end of the cable run is terminated to prevent signal corruption due to signal reflections in the cable.
The Accessory Ports are grouped in Pairs. 1+2, 3+4, 5+6, 7+8. You must terminate the ZONE MIX and Accessories based on which ports you use.

  1. Terminate the ZONE MIX accessory ports, as per the table, using the PORT TERM switches
    ACCESSORY PORT TERMINAL  SWITCH SETTING

    ONE PORT USED| TERM| BOTH PORTS USED| TERM
    Port 1 OR Port 2 used| ON| Port 1 AND Port 2 used| OFF
    Port 3 OR Port 4 used| ON| Port 3 AND Port 4 used| OFF
    Port 5 OR Port 6 used| ON| Port 5 AND Port 6 used| OFF
    Port 7 OR Port 8 used| ON| Port 7 AND Port 8 used| OFF

  2. Terminate the LAST RS485 accessory on the port cable run. Paging station termination
    Australian Monitor ZONEMIX Wiring Guide - fig12 Examples:

Australian Monitor ZONEMIX Wiring Guide - fig13

STEP 5: WP4R, WP10 GPO WIRING (OPTIONAL)

The WP4R and WP10 both have 3 general purpose outputs which can be controlled from the wall panel buttons to trigger external devices such as projectors.

Australian Monitor ZONEMIX Wiring Guide - fig14

GPO Schematic
Each Output is an open collector transistor. Maximum Voltage: 48V Maximum Sink Current: 250mA