CDC-25122-XU1A Teleflex Arrow User Manual

June 5, 2024
Arrow

CDC logo2

CDC-25122-XU1A
12 Fr. 2 Lumen
20 cm catheter length
.035 inch dia. spring-wire guide

Arrowg+ard Blue® You-Bend™ Two-Lumen Hemodialysis Catheterization for High Volume Infusions

Contents:

1: Two-Lumen Cathetert: 12 Fr. (4.06 mm OD) x 20 cm Radiopaque Polyurethane with Blue FlexTip®, Arrowg+ard® Antimicrobial Surface Treatment
1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 26-3/4″ (68 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1: Injection Needle: SafetyGlidewl 25 Ga. x 1″ (2.54 cm)
1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
1: Pressure Transduction Probe
1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer- Slip Syringe
1: Syringe: 3 mL Luer-Lock
1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm
1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
2: 10 mL Luer-Lock Pre-Filled Saline Syringe 1: 5 mL 1% Lidocaine HCI Solution and Alcohol Prep
1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrepo2 One-Step Solution with Hi- Lite OrangeTM Tint
1: SharpsAway® Disposal Cup
1: SharpsAway® II Locking Disposal Cup
1: Maximal Barrier Drape1M with 4″ fenestration
1: Towel 1: Needle Holder
1: Safety Scalpel: #11
1: Checklist/CLIP Sheet
1: Sterile Procedure Sign
1: Medication Label: 1% Lidocaine
2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
1: Dressing: Tegaderm®3 10 cm x 12 cm
1: Surgical Apparel: Impervious Gown
1: Dressing: BIOPATCHe4
1: Surgical Apparel: Bouffant Cap
1: Surgical Apparel: Mask with Eye Shield
1: Suture: 3-0 Braided Silk with Straight Needle
1: Suture: 3-0 Silk with Curved Needle
1: HemoHopper® Fluid Receptacle
1A trademark of Becton, Dickinson, and Company.
2A registered trademark of CareFusion or one of its subsidiaries.
3A registered trademark of 3M Company.
4A  registered trademark of  Johnson  &  Johnson Corporation.

$MR Conditional
Not made with natural rubber latex.
Store between 20 — 25°C (68 — 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication. Contraindications: The Arrow large-bore two-lumen catheter is not designed for long-term 30 days) hemodialysis or for use in patients with thrombosed vessels. The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/ or sulfa drugs.

sambol2

Priming Volume*

Distal| 1.80 mL
Proximal| 1.80 mL

  • Priming volumes are approximate and are done without accessories.

fig55

Flow (mL/min)
† In vitro tests were performed using 3:1 glycerine/saline at 37°C.

sambol1

LBL057058 R00 (2022-02)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Arrow User Manuals

Related Manuals