AK-25123-F Arrow-Howes Large-Bore Multi-Lumen CVC Kit User Guide

June 5, 2024
Arrow

Arrowg+ard Blue® Large-Bore Three-Lumen CVC for High  Volume  Infusions

Contents:

1:
1:
1:
1:
1:
1:
1:
1:
1:
1:
1:
1:
1:
1:
1:
2:
5:
1:
¹A| Arrowg+ard Blue® Three-Lumen Catheter: 12 Fr. (4.1 mm OD) x 20 cm
Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 26-3/4″ (68 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
Injection Needle: 25 Ga. x 1″ (2.54 cm)
Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
Pressure Transduction Probe
Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
Syringe: 3 mL Luer-Lock
Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
5 mL 1% Lidocaine HCI Solution and Alcohol Prep
3 mL Applicator 2% CHG and 70% IPA ChloraPrepel One-Step Solution with Hi-Lite OrangeTM Tint SharpsAway® Disposal Cup
Drape: 24″ x 36″ (61 cm x 91 cm) with 4″ (10 cm) fenestration
Scalpel: #11
Gauze Pad: 2″ x 2″ (5 cm x 5 cm) Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
Suture: 3-0 Braided Silk with Straight Needle
registered trademark of CareFusion or one of its subsidiaries.
---|---

Rx only
Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65
** WARNING:** Cancer and Reproductive Harm. www.P65Warnings.ca.gov
Not made with natural rubber latex.
Store between 20 – 25°C (68 – 77°F). Sterilized using ethylene oxide unless otherwise indicated in the contents list. Fluid path components are non- pyrogenic. Contraindications: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/or sulfa drugs.

Lumen Priming Volume* (mL) Gravity Flow Rate† (mL/hr)
Distal ( 16 G a. ) 0.40 2457
Medial ( 12 G a. ) 1.3 10151
Proximal ( 12  G a. ) 1.2 11039
  • Priming volumes are approximate and are done without accessories. t Flow rate values are approximate and are determined using deionized water at 100 cm head height.

**** Arrow International LLC
Subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd.
Morrisville, NC 27560 USA

www.teleflex.com
LBL052097 R01 (2022-02)
AK-25123-F
12 Fr. 3Lumen 20cm catheter length .035inch dia. spring-wire guide

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Arrow User Manuals

Related Manuals