  • Arrowg+ard Blue® Three-Lumen Catheter: 12 Fr. (4.1 mm OD) x 16 cm
  • Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
  • Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
  • Injection Needle: 25 Ga. x 1″ (2.54 cm)
  • Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
  • Pressure Transduction Probe
  • Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
  • Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
  • Syringe: 3 mL Luer-Lock
  • Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
  • 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
  • 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite Orange™ Tint
  • SharpsAway® II Locking Disposal Cup
  • SharpsAway® Disposal Cup
  • Drape: 41″ x 55″ with 4″ fenestration
  • Needle Holder
  • Safety Scalpel: #11
  • Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
  • Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
  • Suture: 3-0 Silk with Curved Needle

1A registered trademark of CareFusion or one of its subsidiaries.

Rx only

Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65
⚠ WARNING: Cancer and Reproductive Harm.
www.P65Warnings.ca.gov
Not made with natural rubber latex. Store between 20 – 25°C (68 – 77°F). Sterilized using ethylene oxide unless otherwise indicated in the contents list. Fluid path components are non-pyrogenic.
Contraindications: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs. ARROW AK-22123-CDC Lumen CVC for