FLAMA 1319FL 12LT Digital Dehumidifier Instruction Manual

June 5, 2024
FLAMA

Instruction manual

12LT DIGITAL DEHUMIDIFIER

WARNINGS

These symbols are present in the appliance:

SYMBOL DESCRIPTION
WARNING (Risk of fire) This appliance contains R290 propane gas. This

appliance uses a flammable refrigerant gas. If the refrigerant gas leaks and comes into contact with a source of heat or ignition, it generates harmful gases and can cause a fire.
| Strictly follow the instructions in this manual regarding operation and maintenance.
| Before using the appliance, carefully read the whole instruction manual.
| Do not install, operate, or store the appliance in a space smaller than 4 m2.

SAFETY INSTRUCTIONS

Please read these instructions carefully before using the appliance for the first time and keep them for future reference. Use that does not comply with the instructions releases  LAMA from all responsibilities.
After transport or cleaning and maintenance, let the unit rest for 12 hours before connecting the unit to the power supply. Check that the power supply voltage of the installation corresponds to that stated on the rating plate of the appliance.
This appliance must be connected to an earthed socket. This appliance is intended to be used by specialists or trained shop users. In light industry and on farms, or for commercial use by lay people.
Do not install this appliance near sources of heat, water, windows or doors leading to the outside.
This appliance is designed to dehumidify areas with excess moisture.
As with any appliance, its use by children must be properly supervised. This appliance can be used by children aged 8 years and over and by persons with limited physical,  sensory or mental capabilities or lack of experience and knowledge if they are supervised or have received instructions concerning the use of the appliance in a safe way and understand the risks involved. Children must not play with the appliance.
Cleaning and user maintenance must not be carried out by children without supervision.
The appliance must be installed in compliance with national installation regulations.
Do not use the appliance in a potentially explosive environment containing combustible liquids, gases, or dust. Do not use paint, cleaning sprays, anti- insect sprays, or the like ear appliance. Do not pull the plug out of the socket by pulling the power cord. Avoid using “T” sockets or extension cords.
Disconnect the appliance from the power supply after each use. Unplug the appliance from the electrical socket whenever cleaning or maintenance is carried out.
When switching off the appliance, always wait at least 3 minutes before switching it on again. Clean the air filter at least once a week.
This appliance must be transported in an upright position. Always empty the water tank before transporting.
It is important to leave a surrounding space of approximately 50 cm for good air circulation, away from combustible objects. Do not use the appliance if it is not working properly or if it is damaged in any way. Any intervention other than cleaning must be carried out at an Authorized Flama Technical Assistance Service.
Do not attempt to replace the power cord or plug, as this is a dangerous operation. If the power cord is damaged, it must be replaced by an Authorized Flama Technical Assistance service or similarly qualified personnel.
The weighted sound pressure level is less than 70 dB.  This product complies with the Electromagnetic Compatibility and Low Voltage Directives.
This instruction manual is also available in PDF format at www.flame.pt.
SAFETY ADVICE REGARDING THE R290 REFRIGERANT
Carefully read all warnings. This appliance contains 45 g of R290 refrigerant gas.
R290 is a gas that is in compliance with European environmental directives. Do not puncture any of the refrigeration circuit components.
For the defrosting process and to clean the appliance, do not use any instruments other than those recommended in this manual (“Cleaning and maintenance”). The appliance must be placed in an environment free from continuously operating sources of ignition (for example open flames, gas or electric devices in operation).
Do not puncture and do not burn the appliance.
The refrigerant gases may be odorless. The appliance should be installed, used, and stored in an environment larger than 4 m2.
If the appliance is installed, used, or stored in an unventilated space, prevent the pooling of any possible refrigerant leaks, as this carries a danger of fire or explosion if the refrigerant is ignited by electric heaters, ovens or other sources of ignition. The appliance should be stored in a way that avoids mechanical damage.
Technicians who perform work on refrigeration circuits should hold appropriate certification, issued by a credentialed authority, attesting to their competence in handling refrigerants in accordance with a specific standard recognized by the trade associations.
Repair services should be performed based on the recommendations of the appliance manufacturer.
Maintenance and repair services requiring assistance from multiple qualified technicians should be done under the supervision of a person specialized in handling flammable refrigerants.
GENERAL INFORMATION
For optimal performance of your dehumidifier:
Place the dehumidifier on a solid and level surface in an area with at least 50 cm (20 in) of open space on all sides to allow for adequate airflow.
Do not place near a radiator or any other heat source. Ensure that all windows are closed for maximum efficiency.
Ensure that the filter is kept clean. This prevents excess electricity consumption and ensures optimal efficiency. To prevent noise and/or vibration, do not place the appliance on a soft or irregular surface while in operation. To prevent damage, never insert any kind of rod or other soft or hard object into the structure of the appliance.
The capacity of the dehumidifier depends on the temperature and the humidity of the room. At lower temperatures, less humidity will be removed.
If there is an interruption to the power supply, the dehumidifier will restart after 3 minutes (depending on the model). This automatic interval period protects the compressor. ATTENTION:
The dehumidifier must be placed in a vertical position for at least 12 hours before use.
Do not attempt to replace the power cord or plug, as this is a dangerous operation. Have them replaced immediately by a Flama-authorized technical assistance service or by similarly qualified technicians to prevent danger.

DESCRIPTION

  1. Control panel
  2. Indicator light
  3. Lateral grille
  4. Water tank
  5. Filter compartment
  6. Filter
  7. Plug for continuous drainage
  8. Handle
  9. Wheels
  10. Display
  11. Power button (ON/OFF)
  12. Mode button
  13. Humidity control button (HUM)
  14. Timer button (TIMER)
  15. Fan speed button (SPEED)
  16. Lock button (LOCK)

OPERATING INSTRUCTIONS CONTROL PANEL

POWER button (11) – turning the appliance on and off
Ensure that the water tank is in the correct position (after turning on the appliance for the first time, if the full tank indicator lights up, remove the tank and return it to the correct position).
Check that the appliance is plugged into the wall outlet.
After connecting to the power source, all the indicators and the display will light up for 1 second and then turn off. Following an alert sound, the power indicator will light up and the dehumidifier will enter standby mode.
Press the POWER button and the dehumidifier will begin working, with an initial humidity of 60%, in standard automatic mode and high fan mode. Press the POWER button again and the dehumidifier will stop working.
Disconnect the appliance from the power supply, unplugging it from the wall outlet.
MODE button (12)
Press the button to change the appliance’s use mode; the corresponding indicator will light up.
Automatic mode
When the ambient humidity ≥ the defined humidity + 3%, the fan will begin to
operate and the compressor will start up after 3 seconds.
When the ambient humidity ≤ the defined humidity -3%, the compressor will stop. The speed and humidity of the fan can be adjusted in automatic mode.
Continuous drying mode
The dehumidifier continues working, but the humidity cannot be adjusted.
Rest mode
Press the MODE button, which will light up and start the rest function. If no operation occurs within 10 seconds, all the indicators will gradually turn off and the fan speed will automatically change from high to low. Press any button to activate the indicator. Press the MODE button again to leave rest mode.
The humidity is adjustable in rest mode.
Humidity control button (HUM) (13)
In automatic mode or rest mode, the button can be pressed to adjust the defined humidity.
Each time the button is pressed, the defined humidity increases by 5% within the range of 30%–80%. Press and hold this button to see the current ambient temperature. 5  seconds later, the screen will return to showing the current humidity.
Timer button (TIMER) (14)
Press this button to define the timer function for between 0-24 hours. Each interval is of 1 hour. Each time the button is pressed, the time increases by 1 hour and the corresponding time is shown on the screen. Setting the value to “00” will cancel the timer function. The indicator will turn off.
After the timer is set and finished, the timer LED will remain lit during the set period of time. After the time is up, the timer LED will turn off automatically. When operating,  et the time for the dehumidifier to turn off; In rest mode, set the time for the dehumidifier to turn on.
Fan speed button (SPEED) (15)
The speed of the fan can only be adjusted in automatic mode.
Press this button to alternate the fan speed between low and high. The corresponding fan speed indicator will light up.
Lock button (LOCK) (16)
Press and hold this button to activate the child lock function. The child lock indicator light will turn on. All the buttons will be locked and non- operational.
Press the button again and the indicator light will turn off and the button will be deactivated. Turning off the dehumidifier will automatically cancel the child lock function.
Indicator light (2)
Ambient humidity <45% – blue light. 45≤ ambient humidity ≤65% – green light. Ambient humidity > 65% – red light. If the display shows E0, E2, CL, CH, LO, or HI, the light will be red.
EMPTYING THE WATER TANK
When the tank is full, the dehumidifier will make a buzzing sound and the “full tank” light will turn on.
Press the POWER button to turn off the dehumidifier.
Pull on the water tank and simply slide it out of the dehumidifier.
Empty the water down a drain or outside. Clean the interior and exterior of the tank. Return the empty tank to the dehumidifier. Press the POWER button to continue operation.
If the “full tank” light does not turn off, check that the tank and the float are correctly positioned.
Notice
Do not discard the water tank magnets and plastic rivets. Otherwise, the dehumidifier will not automatically stop working when the water tank is full, and the condensed water ill overflow and damage the floor of the room, it is in.
Make sure to clean the condensed water in the water tank before restarting the operation of the dehumidifier. If the water tank is dirty, rinse it with clean water. Avoid using detergents, chemical dust removers, diesel oil, benzene, thinners or other solvents. These will damage the water tank and cause leaks. Return the empty tank to the dehumidifier. Otherwise, the full tank indicator will remain red and the dehumidifier cannot restart.

CONTINUOUS DRAINAGE

For continuous operation or automatic dehumidification, connect the drain hose to the dehumidifier. The condensed water can automatically flow to a bucket or drain by gravity.
Straighten the drainage tube. Insert one end of the hose into the cistern orifice and connect the other end to the bathtub, outdoors, a bucket-like recipient, or to a designated drainage area.
How to correctly place the drainage hose In continuous drainage mode, the hose should be placed below the drainage orifice. Avoid uneven surfaces and do not bend the hose.
WARNING
Do not block the drain or drainage tube. Do not bend the drainage tube. The height of the drain should be lower than the outlet. The drainage tube should be safely connected to the outlet.

CLEANING AND MAINTENANCE

For safety reasons, ensure that the dehumidifier is turned off before cleaning or repairing it. Cleaning the exterior of the dehumidifier Clean the exterior with a clean and dry cloth.
If the dehumidifier is very dirty, clean it with a neutral detergent and then remove the detergent with a damp cloth. Do not wash the appliance with a hose as this will cause energy leaks and the risk of electric shock.
Cleaning the air filter (every 2 weeks)
Dust accumulates in the filter and restricts airflow. Restricted airflow reduces the efficiency of the system and, if blocked, can damage the dehumidifier.
The air filter requires regular cleaning. The air filter is removable to facilitate cleaning. Do not plug in the dehumidifier without the air filter or it may become contaminated.
Remove the water tank from the body of the appliance and then remove the filter from the lower part of the rear lid. Use a vacuum cleaner to gently suction the
dust from the surface.
If the filter is very dirty, wash it with water and a mild detergent, then dry it very well. Return the filter to place.

PRECAUTIONS AND WARNINGS

Empty the water tank when full or when the full tank indicator appears on the screen. After emptying the removable water tank, return it to its original position. The appliance will resume operation. Whenever the appliance stops, you should wait for at least 3 minutes before restarting it to prevent damage to the compressor.
If the appliance does not start or if it intermittently stops working for unknown reasons, checks the power cord and plug. If these are in normal working condition, unplug the appliance from the wall outlet and wait 10 minutes before restarting it. If after 10 minutes the appliance does not restart, contact FLAMA (customer support line) or an authorized technical support service.
While the appliance is working, the compressor produces heat, which can raise the temperature of the room. This is normal and does not affect the operation of the appliance.

STORAGE

If you will not use the appliance for a long period of time, follow the following steps: Remove the plug from the wall outlet and empty the water tank. Allow the water tank and dehumidifier to dry completely. Clean the air filter.
Store the appliance vertically in a dust-free location, preferably covered with a plastic covering.

TROUBLESHOOTING

ANOMALY PROBABLE CAUSE SOLUTION
The appliance does not turn on. It is not connected to a power source. Plug

it into the wall outlet.
The water tank is full.| Empty the water tank.
The water tank is not correctly placed.| Reposition the water tank.
Temperature < 5°C or > 35°C.| Appliance protection.
Poor performance.| The air filter is clogged.| Clean the air filter.
The intake or outlet ducts are obstructed.| Remove the obstruction from the intake or outlet ducts.
Little dehumidifying capacity.| Dirty air filter.| Clean the filter.
Air intake or outlet blocked.| Unblock the air intake or outlet.
Noise.| The appliance is unstable.| Check that the appliance is in a stable position.
The air filter is clogged.| Clean the air filter.
E2| Humidity sensor.| Contact technical assistance.
LO| Ambient humidity below 20%.| The dehumidifier turns off to protect itself.
Oi| Ambient humidity above 90%.
Cl| Protection against low temperature.
Ch| Protection against high temperature.

REQUIRED INFORMATION

Power supply 220V-240V~, 50Hz
Dehumidification capacity (30°C/RH80%) 10L/day
Nominal input power 195W (30°C/80%)
Refrigerant / Load R290 / 0.045 kg
Operating temperature 5°C- 35°C
Tank capacity 2.0 L
Dimensions (L x D x H) mm 250x220x445 mm
Net weight 10 kg

ANOMALIES AND REPAIR
In case of malfunction, please take the appliance to an authorized Technical Assistance Service. Do not attempt to disassemble or repair the appliance, as this may be dangerous.
PROTECTING THE ENVIRONMENT
This symbol indicates the separate collection of electrical and electronic equipment. The main objective of the separate collection of this waste is to reduce the quantity to be disposed of and promote reuse, recycling, and other forms of recovery in order to reduce its negative effects on the environment.
When it is no longer in use, this appliance must not be disposed of together with other unsorted municipal waste. The user is responsible for delivering it free of charge to the elective collection facilities available for that purpose. Pieces of equipment that are no longer in use can also be taken back at points of sale, by purchasing new pieces of equipment that are equivalent and have the same functions.
For more detailed information on collection points, please contact your City Council or a point of sale for this equipment.

  Fábrica de Louças e Electrodomésticos, S.A.
Rua Alto de Mirões, nº249
Zona Industrial de Cesar
3700-727 Cesar
Portugal
t. +351 256 850 170
f. +351 256 850 179
www.flama.pt
info@flama.pt
I1319.01

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals