intertek UBS-879120 Square Base Stand Weight for Patio Market Table Umbrella Outdoor Bronze User Guide

May 15, 2024
Intertek

intertek UBS-879120 Square Base Stand Weight for Patio Market Table Umbrella Outdoor Bronze

intertek UBS-879120 Square Base Stand Weight for Patio Market Table Umbrella
Outdoor Bronze

Test Report

Applicant: LINHAI TAIJI CRAFTS CO., LTD. Date: 20 Sep, 2023
NO 7, DONGGANG MIDDLE ROAD, DAYANG STREET, LINHAI CITY, ZHEJIANG PROVINCE, CHINA
Attn: MELINDA

Sample Description:
One (1) group of submitted sample said to be:
Item Name : RR RD RESIN UMB BASE 17.5″ 26.4 LBS
Item No. : UBS-879120
Quantity : 1pc
Goods Exported To: USA
Country Of Origin : China

Tests Conducted:
As requested by the applicant, for details refer to attached page(s).

Conclusion:
The submitted samples conformed to MPS test protocol for Umbrella Base (Version: 2)

Test Property Rating Remarks / Comments
Pass Fail
Chemical Test X
Physical Properties X
Construction & Workmanship X
Performance Test X
Labeling Requirement

Meet Federal Regulation ( X )
Fail Federal Regulation ( )
Meets ITS Performance Std ( X )
Fails ITS Performance Std ( )

Comments: Nil
Remarks: #1 No artwork of packaging and label were provided for review.

Authorized By: Intertek Testing Services Ltd. Zhejiang
Bobo Yao Assistant General Manager
Signature
Symbol

Conclusion:

Tested samples Submitted carton of packaged product
Standard ISTA test procedure 1A: 2014
Result Pass

Tests Conducted

  1. As requested by the applicant, the submitted sample was tested as per MPS-03087-US Dated Apr 26, 2022, the test results were listed as below:
    Test Description| Test Method| Requirement| Result| Rating
    ---|---|---|---|---
    Chemical Test
  • Lead Content in Paint or Similar Surface Coating| With reference to 16 CFR 1303| Shall not contain Lead or Lead compounds in which the Lead content is in excess of 0.009% (90ppm) by weight of the total content.| Meet| P
    †* Toxic Elements in Packaging Components| Various US State Laws / TPCH| Packaging shall comply with TPCH in those states with legislation. Total concentration of Pb, Cd, Hg and hexavalent Cr shall not exceed100 ppm. In lieu of testing, test report or guarantee letter can be submitted if dated within 1 year.| NA| –

  • Phthalates in Packaging Components| TPCH and its 2021 Update| The sum of phthalates in package or packaging component shall not exceed 100 ppm. **** In lieu of testing, test report or guarantee letter can be submitted if dated within 1 year.| NA| –

  • PFAS in Packaging Components| TPCH and its 2021 Update| There shall be no detectable PFAS in package or packaging component. In lieu of testing, test report or guarantee letter can be submitted if dated within 1 year.| NA| –
    †* EPA TSCA Title VI – Composite Wood| 40 CFR 770 / Client Requirement|

    * If regulated composite wood is not present in the sample, result is N/A.
    * If regulated composite wood is present in the sample:
    * Vendors shall provide completed ITS’s Certificate of Compliance (COC) for TSCA Formaldehyde Emission Standard which certify that the finished product containing composite wood (defined by 40 CFR 770) are compliant with the TSCA formaldehyde emission standards, rules and regulations.

**Note:**

  *  **Regulated composite wood includes:**
  * Hardwood plywood (HWPW)
  * Medium-density fiberboard (MDF)
  * Thin medium-density fiberboard (Thin MDF)
  * Particleboard (PB)
  *  **Rating Schedule:**
  * On or after June 1, 2018:
  * Compliant submission shall be rated as pass. Non- compliant submission shall be rated as fail.

| NA| –
Physical Properties
Overall Dimensions| ITS-M0059| Report actual. Shall meet label claims (If applicable).| R: Φ17.3in.x12.8in.(H) No claims| –
Overall Weight| ITS-M0059| Report actual. Shall meet label claims (If applicable).| R: 26.73lb.
No claims| –
Pole Holder Inner Diameter| ITS-M0059| Report actual. Shall meet label claims (If applicable).| R: Φ1.58in. No claims| –
Depth of Pole Insert| ITS-M0059| Report actual. Shall meet label claims (If applicable).| R: 9in.
No claims| –
Pitch of Pole Insert| ITS-M0059| The axis of the insert slot of umbrella base shall not deviate be more than 2° from the vertical axis.| Meet| P
Material Type| Visual Check| Report actual. Shall meet label claims (If applicable).| R: Cement, Metal, Plastic
No claims| –
Construction & Workmanship
Sharp Points / Edges| With reference to 16 CFR 1500.48 / 1500.49| Shall have no sharp points or edges as received, other than those required for function.| Meet| P
Workmanship| Visual Check| Shall have no discernible surface degradation, including but not limited to crazing, shivering, denting, bubbles, cracks, stains, deformations, chips, fractures, heavy lines, waves, shear marks, scratches, scuff marks, indentations, or blisters.| Meet| P
Components| Visual Check| Shall have no components missing, malformed, and/or fractured.| Meet| P
Weld / Glue| Visual Check| Shall be smoothly ground and free from pits and splatter.| Meet| P
Performance Test| | | |
Functionality| ITS-M0061| Shall function as intended as received.| Meet| P
Assembly| ITS-M0068| Shall be assembled as instructed or intended without any adverse findings obstructing assembly.| Meet| P
Pole Securement| In-house Method| For umbrella base:

  * Shall tighten easily to hold umbrella securely in upright position.
  * Shall be adjustable to accommodate the minimum and maximum labeled pole sizes.  

Report minimum and maximum pole sizes tested.

| Meet (No labeled, Maximum test: Φ1.48in.)| P

  • Stability with Umbrella Inserted| ITS-M0015| There shall not tip over after inserting the testing

umbrella in umbrella base on a horizontal floor. When a tilt-type umbrella is installed as intended and tilted to a position most likely to cause tip-over. Then repeat the test at 8° incline surface. Record umbrella height, weight, pole diameter and testing position (such as testing height or tilt angle if applicable).
NOTE: Only perform the test when testing umbrella is provided by vendor for testing.

| Meet (Test with 9ft umbrella: Height: 92.5 in. Weight: 4.35kg Pole diameter: 1.48 in.)| ****




P

  • Leakage (For umbrella base intended to be filled)| ITS-M0061| Umbrella base shall have no leakage when filled with the intended material (such as water or sand) of claimed capacity for 24 hours.| NA (No filled)| –
  • Cross Cut Test| EN ISO 2409| For coating on metal component: Classification 2 min.| Meet| P
  • Cyclic Test (For operable component)| ITS-M0061| Operable component shall withstand 100 times actual use cycles without failure or loss of functionality.| NA| –
  • Effects of Extreme Temperature| ITS-M0007| Shall withstand for 24 hours at 0 degrees Fahrenheit and then 24 hours at 120 degrees Fahrenheit with no structural failure or visual change.| Meet| P
  • Moisture Content (For solid wood)| ITS-M0054| Moisture content of solid wood shall be within 8% – 12%.| NA| –
  • Resistance to Corrosion

(For metal components)

| ASTM B117| Metal components shall withstand 24 hours in 5% salt spray (fog) with no major corrosion or visual change.| Meet| P

  • Transit Testing (By request only)| ISTA Procedure as Appropriate to Package| Packaged product shall be tested to applicable ISTA procedure and method, based on package configuration. Inspect package and product for damage upon completion of test. Report results.| Meet| P
    Labeling Requirement
    †* EPA TSCA Title
    VI – Composite Wood – Finished Good Labeling| 40 CFR 770.45(c) /
    40
    CFR 770.45(e)| Finished goods containing regulated composite wood shall comply with the labeling requirements found in 40 CFR 770.45(c) unless the finished good qualifies for the de minimize exception found in 40 CFR 770.45(e).

    * A finished good does not require labeling per 40 CFR 770.45(c) if the finished good does qualify for the de minimize exception in 40 CFR 770.45(e). If the finished good does qualify for the de minimize exception, result is N/A.
    * A finished good does require labeling per 40 CFR 770.45(c) if the finished good does not qualify for the de minimize exception in 40 CFR 770.45(e).
    * At a minimum, the label must be on the product OR the packaging.
    * The label may be applied as a stamp, tag, or sticker
    * The label shall include, at a minimum, in legible English text:
    1. Fabricator’s name
    2. Date the finished good was produced (in month/year format)
    3. A statement of compliance to denote that the finished good complies with TSCA Title VI

Example: XXX Company MM/YYYY TSCA Title VI compliant for formaldehyde

Notes:

  * A de minimize amount of regulated composite wood is defined as regulated composite wood content not exceeding 144 square inches, based on the surface area of the largest face of the finished good.
  * The de minimize exception is not available to finished goods or component parts that are designed to be used in combination or in multiples to create larger surfaces, finished goods, or component parts.
  * Rating Schedule:
  * On or after June 1, 2018*:  

Compliant submission shall be rated as pass. Non- compliant submission shall be rated as fail.

Products labeled as CARB acceptable until March 21, 2019.
On or after March 22nd, only TSCA label acceptable.

| NA| –

IMPORTANT NOTE: The information presented under the “Requirements / Limits” column of this protocol is for information only and does not replace the content of the standard. Details of the requirements should be referred to the original standards.

Tests Conducted

REMARK: Additional tests may be incurred subject to the final samples reviewed by Intertek.

KEY: † : Mandatory Requirement * : Additional charge items

Results Key:

NA Not Applicable NT Not Tested
NR Not Requested R Recorded
C Claimed P Pass
F Fail

Date of Sample Received: Aug 30,2023
Testing Period: Aug 30,2023 to Sep 19,2023

TRANSPORTATION TEST (ISTA 1A)

As per ISTA integrity test procedure 1A: 2014, the performance and integrity of the packaged product was evaluated.
Number of sample tested: One (1) carton

  1. Shipping mark: Nil
  2. Description of package:
    External container size (inch) : Length 21.75 x width 18.75 x depth 3.5
    Gross weight (lbs) : 28.49
    Box style : Full overlap slotted container (FOL)
    Wall Corrugated board : Double
    Box maker’s certificate : No
    Joint : Glued joint
    Closed with : Pressure-sensitive tape
    Style : Top opening.
    (See enclosed picture 1)
Test procedure

(a) Atmospheric preconditioning Laboratory ambient temperature and humidity for twelve (12) hours at: 22.5 °C, 55 % RH.
(b) Vibration test
Mode of vibration: Rotary
(b1) Before a single 90°horizontal rotation
Vibration frequency: (CPM) 200 cycles per minute
Duration of testing: 35 Minutes and 30 seconds
Tests Conducted
Number of Vibration: (Cycles) 7,100
(b2)After a single 90°horizontal rotation Vibration frequency: (CPM) 200 cycles per minute
Duration of testing: 35 Minutes and 30 seconds
Number of Vibration: (Cycles) 7,100
Remark: No puncture of carton box was observed.
(c) Drop test
Method used: Free fall drop
Number of drops: 10
Height of drop (inches): 24

  1. No puncture of carton box was observed.
  2. The test drop height varies with the weight of the packaged-product.
    The drop height and the weight were listed as below:
    ** Packaged-product weight (lb)| Drop height (in.)**
    ---|---
    0≤ G <21lb| 30
    21≤ G <41 lb| 24
    41≤ G <61 lb| 18
    61≤ G <100 lb.| 12
    100≤ G <150 lb.| 8
  3. The drop sequence and orientation were listed as below:
    Sequence| Orientation| Specific face edge or corner| Verify face edge or corner
    ---|---|---|---
    1| Corner| Most fragile face-3 corner, if not known, test 2-3-5| Test
Report
    2| Edge| Shortest edge radiating from the corner tested
    3| Edge| Next longest edge radiating from the corner tested
    4| Edge| Longest edge radiating from the corner tested
    5| Face| One of the smallest face
    6| Face| Opposite small face
    7| Face| One of the medium face
    8| Face| Opposite medium face
    9| Face| One of the largest face
    10| Face| Opposite large face
  4. Interior packaging:

Tests Conducted

Result: Neither visible damage nor malfunction was observed on the contents of the packaged product.
Date Sample Received: Aug 22, 2023
Testing Period: Aug 22, 2023 to Aug 25, 2023

Total Lead (Pb) Content

As per U.S. Code of Federal Regulations title 16 part 1303, acid digestion method was used and total Lead content was determined by Inductively Coupled Argon Plasma Spectrometry.

Tested component (1)
Result (%) ND
Limit (%) 0.009

The limit was quoted according to CPSC Regulation CFR title 16 Part 1303 for Lead (Pb) content.
Remark: ND = Not Detected
Detection Limit = 0.002%
Tested Components: See component list in the last section of this report.
Date Sample Received: Aug 22, 2023
Testing Period: Aug 22, 2023 to Sep 14, 2023

Tested components:

  1. Black coating on metal
    Picture 1: Submitted sample
    Submitted sample
    Picture 2: Submitted Sample
    Submitted sample
    Picture 3: _Exhibit
    Exhibit
    Picture 4: _Exhibit
    Exhibit
    Picture 5: _Exhibit
    Exhibit
    Picture 6: _Exhibit
    Exhibit
    Picture 7: _Exhibit
    Exhibit
    Picture 8: _Exhibit
    Exhibit
    Picture 9: _Exhibit
    Exhibit
    Picture 10: _Exhibit
    Exhibit

This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek’s provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or will full misconduct.
This report shall not be reproduced except in full, without written approval of the laboratory.

CUSTMER SUPPORT

INTERTEK TESTING SERVICES LTD. ZHEJIANG
Building No.2, Juanhu Science and Technology Innovation Park, No. 500 East Shuiyueting Road, Haining City, Zhejiang Province, China. 314400


Tel:
+86 573 87137200
Zip:314400
www.intertek.com
www.intertek.com.cn