CDC-41541-MPK1A Pressure Injectable Arrowg+ard Blue Advance One-Lumen Midline Instructions
- June 5, 2024
- Arrow
Table of Contents
CDC-41541-MPK1A Pressure Injectable Arrowg+ard Blue Advance One-Lumen Midline
Contents
1: TaperFree® Catheter with Arrowg+ard Blue Advance™ Antimicrobial/
Antithrombogenic Protection
1: 4.5 Fr. (1.6 mm OD) x 15 cm, Pressure Injectable, Blue FlexTip®
1: GlideThru™ Peel-Away Sheath: 4.5 Fr. x 2-3/4″ (7 cm) Radiopaque over 4.5
Fr. Dilator
1: Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm)
(Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow
Advancer
1: Injection Needle: SafetyGlide™2 25 Ga. x 5/8″ (1.60 cm) RW
1: Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) 1: Introducer Needle:
Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
1: Syringe: 10 mL Luer-Lock
2: Syringe: 3 mL Luer-Lock
2: 10 mL Luer-Lock Pre-Filled Saline Syringe
1: Skin Protectant Prep
1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution
1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-
Lite Orange™ Tint
2: Dust Cap: Non-Vented 1: SecondSite™ Adjustable Hub: Catheter Clamp
1: SecondSite™ Adjustable Hub: Fastener
1: SharpsAway® Disposal Cup
1: SharpsAway® II Locking Disposal Cup
1: Catheter Trimmer 1: Towel: 24″ x 36″ (61 cm x 91 cm)
1: Maximal Barrier Drape™ with two 13 cm (5″) x 15 cm (6″) fenestrations
1: Towel
1: Safety Scalpel: #11
1: Sterile Procedure Sign
1: Patient ID Card
1: Chart Sticker
1: Medication Label: 1% Lidocaine
1: Checklist/CLIP Sheet
1: Patient Information Booklet
2: Paper Tape Measure
1: Tourniquet
10: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
10: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
1: Dressing: Tegaderm®4 15.5 cm x 10 cm
1: Surgical Apparel: Impervious Gown
1: Dressing: BIOPATCH®5
1: Dressing: STATLOCK®6 Catheter Stabilization Device
1: Surgical Apparel: Mask with Eye Shield
1: Surgical Apparel: Bouffant Cap
1: Surgical Apparel: Mask
1: Tape: Steri-Strip®4
1: HemoHopper® Fluid Receptacle
1Licensed under US Patent No. 7,329,412.
2A trademark of Becton, Dickinson and Company.
3A registered trademark of CareFusion or one of its subsidiaries.
4A registered trademark of 3M Company.
5A registered trademark of Johnson & Johnson Corporation. 6A registered
trademark of C. R. Bard, Inc.
Not made with natural rubber latex.
Store between 20 – 25°C (68 – 77°F). Arrow International provides the enclosed
medication label(s) for your convenience. Please ensure that these labels are
applied to the correct syringe and corresponding medication.
Contraindications: The Arrowg+ard Blue Advance Pressure Injectable Midline
is contraindicated for patients with known hypersensitivity to
chlorhexidine.
Lumen
|
*Priming Volume (mL)**
| Gravity Flow Rate† (mL/hr)| Pump Flow Rate†† (mL/hr)|
MAX Pressure Injection Flow Rate (mL/sec)**
---|---|---|---|---
Distal (17 Ga.)| 0.31| 2009| 8820| 5
- Priming volumes are approximate and are done without accessories.
† Flow rate values are approximate and are determined using deionized water at 100 cm head height.
†† Pump flow rates are determined at maximum pump pressure of 10 psig and represent approximate flow capabilities. ** Pressure injection flow rates are determined using media of 11.8 centipoise (cP) viscosity, with 152 cm administration set tubing.
Read User Manual Online (PDF format)