MSAN/DSLAM product portfolio

OSP Remote/central

Port density|  |  |  |  |  |  |  |  |  |  |  |  |  |  |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
ADSL2+| –| –| –| –| –| –| 24| 128| 360| 720| 1152| –| –| –| –
ADSL2+

Combo

| –| –| –| –| –| –| –| –| 240| 480| 768| –| –| –| –
SHDSL| –| –| –| –| –| –| 32| –| 240| 480| 768| –| –| –| –
VDSL2| –| –| –| –| 24| 24| –| 96| 240| 480| 768| –| –| –| –
VoIP| –| –| –| –| –| 24| –| 256| 360| 720| 1152| –| –| –| –
VDSL2/

Vectoring

| –| –| –| 24| –| –| –| –| –| –| –| 96| 192| 2×192| 3×192
1G AON| –| –| –| –| –| –| –| –| 120| 240| 384| 80| 200| 400| 600
PON| –| –| –| –| –| –| –| –| –| –| –| 32| 64| 160| -*
10G PON| –| –| –| –| –| –| –| –| –| –| –| 16| 32| –| –
G.fast| 4 (106 MHz)| 16 (106 MHz)| 8 (212 MHz)/

16 (106 MHz)

| –| –| –| –| –| –| –| –| –| –| –| –

  • By project request|  |  |  |  |  |  |  |  |  |  |  |  |  |  

MSAN/DSLAM key features

Category Model Key features

Central **MSAN

**| IES-6000

| •  Maximum 1152-port VoIP density, 1152-port ADSL2+ density, 768-port ADSL2+ combo density, 768-port SHDL density, 768-port VDSL2 density, or 384-port Gigabit Ethernet density

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Full redundancy of management card and power module

•  Comprehensive QoS to enhance triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

| IES6217

| •  Maximum 192×3-port vectoring VDSL density, 600-port Gigabit Ethernet density

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Board-Level Vectoring (BLV) and System-Level Vectoring (SLV)

•  Full redundancy of management card and power module

•  Comprehensive QoS enhanced triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

| IES-5112

| •  Maximum 720-port ADSL2+ density, 480-port ADSL2+ combo density, 480- port SHDSL density, 480-port VDSL2 density, 720-port VoIP density, or 240- port Gigabit Ethernet density

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Full redundancy of management card and power module

•  Comprehensive QoS to enhance triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

| IES5212

| •  Maximum 192×2-port vectoring VDSL density, 400-port Gigabit Ethernet density, or 160-port GPON density

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Board-Level Vectoring (BLV) and System-Level Vectoring (SLV)

•  Full redundancy of management card and power module

•  Comprehensive QoS enhanced triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

| IES-5106

| •  Maximum 360-port ADSL2+ density, 240-port ADSL2+ combo density, 240- port SHDSL density, 240-port VDSL2 density, 360-port VoIP density, or 120- port Gigabit Ethernet density

•  Flexible ACL, VLAN-aware DHCP and anti-IP/MAC address spoofing to prevent malicious attack

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Comprehensive QoS to enhance triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

| IES5206

| •  Maximum 192-port vectoring VDSL density, 200-port Gigabit Ethernet density, 64-port GPON density or 32-port XGS-PON density

•  Supports symmetric XGS-PON for residential, cloud, and enterprise services

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Board-Level Vectoring (BLV) and System-Level Vectoring (SLV)

•  Full redundancy of management card and power module

•  Comprehensive QoS enhanced triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

Category Model Key features

Central **MSAN

**| IES4204

| •  Maximum 96-port vectoring VDSL density, 80-port Gigabit Ethernet density, 32-port GPON density, or 16-port XGS-PON density

•  Supports symmetric XGS-PON for residential, cloud, and enterprise services

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Full redundancy of management cards and power module

•  Comprehensive QoS enhanced triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

Remote **MSAN/ DSLAM

**| IES4105

| •  Maximum 128-port ADSL2+ density, 96-port VDSL2 density, or 256-port VoIP density

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  DHCP option 82 and PPPoE IA features support versatile IP address assignment

•  Comprehensive QoS enhanced triple-play experience

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

| IES-1000

| •  Maximum 24-port ADSL2+ density, or 32-port SHDSL density

•  Two Fast Ethernet interfaces for uplink

•  Supports 802.1p QoS, priority queuing, 802.1q VLAN tag, and multicast

•  1U, DC or AC power, and built-in POTS splitter

•  2 FE electrical interface for uplinks and subtending

| VES1724-56B2 VES1724-55C VES1724-58V

| •  Maximum 24-port VDSL2 density (VES1724-56B2, VES1724-58V), 24-port VoIP density (VES1724-58V), or 24-port vectoring VDSL density (VES1724-55C)

•  Complies with VDSL2 standards including ITU-T G.993.2, G994.1, and G.997.1

•  VDSL2 bonding and G.INP

•  SIP and H.248 for smooth voice over IP migration (VES1724-58V)

•  AC or DC dual-power with battery charge (VES1724-58V)

•  Fanless design for energy-saving and energy-saving and extended product life (VES1724-56B2, VES1724-55C)

•  Comprehensive QoS enhanced triple-play experience

•  Sophisticated OAM&P features

•  Temperature-hardened for flexible installation

| GES1316-FSA GES1116-FSA

| •  G.fast with G.vectoring and VDSL2/35b fallback (GES1316-FSA)

•  Multi-service interfaces including G.fast, VDSL2, GPON, and fiber-based GbE

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Comprehensive QoS enhanced triple-play experience

•  Sophisticated OAM&P features

•  AC/DC dual-power with battery charge function

•  Fanless design for energy-saving and extended product life

•  Temperature-hardened for flexible installation

**OSP

**| GES2104-R55/A55

| •  G.fast with G.vectoring and VDSL2 fallback

•  Multi-service interfaces including G.fast, VDSL2, GPON, and fiber-based GbE services

•  Flexible ACL, VLAN-aware DHCP, and anti-IP/MAC address spoofing to prevent malicious attacks

•  Field-proven IGMP snooping and proxy for IPTV deployments

•  Comprehensive QoS enhanced triple-play experience

•  Sophisticated OAM&P features

•  Environmental-hardened for flexible installation

•  Fanless design for energy-saving and extended product life

MSAN/DSLAM feature matrix

 |  | Central MSAN|  |  |  |  |  |
---|---|---|---|---|---|---|---|---
 |  | IES6217| IES5212| IES5206| IES4204| IES-6000| IES-5112| IES-5106
Product name|  | 14U 17-slot Temperature- Hardened Chassis MSAN| 8.3U 12-slot Temperature- Hardened Chassis MSAN| 5U 6-slot Temperature- Hardened Chassis MSAN| 2U 4-slot Temperature- Hardened Chassis MSAN| 12.5U 17-slot Temperature- Hardened Chassis MSAN| 8U 12-slot Temperature- Hardened Chassis MSAN| 5U 6-slot Temperature- Hardened Chassis MSAN
Power|  | -36 to -72 V DC| -36 to -72 V DC| -36 to -72 V DC or

100 to 240 V AC

| -36 to -72 V DC or

100 to 240 V AC

battery charger

| -36 to -72 V DC| -36 to -72 V DC| -36 to -72 V DC
Power redundancy| Yes| Yes| Yes| Yes| Yes| Yes| Yes
Operating temperature| -40°C to 65°C| -40°C to 65°C| -40°C to 65°C| -40°C to 65°C| -40°C to 65°C| -40°C to 65°C| -40°C to 65°C
Operating humidity| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH
Slot| Uplink| 2/1| 2| 2/1| 2| 2/1| 2| 1
Downlink| 15/16| 10| 4/5| 2| 15/16| 10| 5
Interface|  |  |  |  |  |  |  |
Uplink| 1000BASE- SX/LX| 4/8| 4/8| 4/8| 4 + 4| 4| 4| 4
10000BASE-SX/LX/ZX| 4/8| 4/8| 4/8| 4 + 4| 2| 2| 2
Downlink| 10G PON interface| –| –| 32 XGS-PON| 16 XGS-PON| –| –| –
PON interface| –| 160| 64| 32| –| –| –
GE interface| 600| 400| 200| 80| 384| 240| 120
VDSL2 interface| 192 x 3 (Vectoring)| 192 x 2 (Vectoring)| 192 (Vectoring)| 96 (Vectoring)| 768| 480| 240
ADSL2+ interface| –| –| –| –| 1152| 720| 360
ADSL2+ combo interface| –| –| –| –| 768| 480| 240
G.SHDSL.bis interface| –| –| –| –| 768| 480| 240
VoIP interface| –| –| –| –| 1152| 720| 360
PON|  |  |  |  |  |  |  |
Maximum splitter ratio| GPON 1 : 128| GPON 1 : 128| 10G PON: 1 : 256

GPON: 1 : 128

| 10G PON: 1 : 256

GPON: 1 : 128

| –| –| –
Type B protection| Yes| Yes| Yes| Yes| –| –| –
AES|  | Yes| Yes| Yes| Yes| –| –| –
SFP digital diagnostic management| Yes| Yes| Yes| Yes| –| –| –
QoS|  |  |  |  |  |  |  |
802.1p priority queue| 8| 8| 8| 8| 8| 8| 8
802.1q tag-based VLAN| Yes| Yes| Yes| Yes| Yes| Yes| Yes
SPQ/WFQ|  | Yes| Yes| Yes| Yes| Yes| Yes| Yes
DBA|  | Yes| Yes| Yes| Yes| –| –| –
Security|  |  |  |  |  |  |  |
IGMP v2, v3|  | Yes| Yes| Yes| Yes| Yes| Yes| Yes
IGMP fast leave|  | Yes| Yes| Yes| Yes| Yes| Yes| Yes
Multicast VLAN|  | Yes| Yes| Yes| Yes| Yes| Yes| Yes
MLDv1 & MLDv2 snooping and proxy| Yes| Yes| Yes| Yes| Yes| Yes| Yes
Management|  |  |  |  |  |  |  |
SNMP v2c, v3|  | Yes| Yes| Yes| Yes| Yes| Yes| Yes
Web management| Yes| Yes| Yes| Yes| Yes| Yes| Yes
CLI management| Yes| Yes| Yes| Yes| Yes| Yes| Yes
EMS management| NetAtlas EMS| NetAtlas EMS| NetAtlas EMS| NetAtlas EMS| NetAtlas EMS| NetAtlas EMS| NetAtlas EMS
Physical specifications
Dimensions (WxDxH)(mm/in.)| 440 x 275 x 622/

17.32 x 10.83 x 24.49

| 440 x 275 x 370/

17.32 x 10.83 x 14.57

| 440 x 275 x 222/

17.32 x 10.83 x 8.74

| 440 x 285 x 89/

17.32 x 11.22 x 3.5

| 440 x 250 x 544/

17.32 x 9.84 x 21.41

| 440 x 250 x 363/

17.32 x 9.84 x 14.29

| 440 x 250 x 215/

17.32 x 9.84 x 8.46

Weight (kg/lb.)|  | 25.5/56.22| 15.5/34.17| 13/28.66| 10.6/23.37| 15/33.07| 13.34/29.41| 10.2/22.49

MSAN/DSLAM feature matrix

    Remote MSAN/DSLAM         OSP
    IES4105 IES-1000 VES1724-56B2 VES1724-55C VES1724-58V
GES1316-FSA GES1116-FSA GES2104-R55/A55
Product name   2U 5-slot Temperature- Hardened Chassis Remote MSAN 1U
2-slot Remote MSAN and Line Cards 24-port Temperature- Hardened VDSL2 Box
DSLAM 8/16-port Temperature-Hardened G.fast DPU 16-port Temperature-Hardened
G.fast DPU 4-port Environmental-Hardened G.fast DPU
Power   -36 to -72 V DC or

100 to 240 V AC or dual power

| -36 to -72 V DC or

100 to 240 V AC

| -36 to -72 V DC or

100 to 240 V AC

| -36 to -72 V DC or

100 to 240 V AC

battery charger

| -36 to -72 V DC or

100 to 240 V AC

battery charger

| 100 to 240 V AC or reverse power feeding
Operating temperature| -40°C to 65°C| 0°C to 50°C| -40°C to 65°C| -40°C to 60°C| -40°C to 65°C| -40°C to 65°C
Operating humidity| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH| 10% to 95% RH
Slot| Uplink| 1| –| –| –| –| –
 | Downlink| 4| –| –| –| –| –
Interface|  |  |  |  |  |  |
Uplink| 100BASE-SX/LX| –| 2| –| –| –| –
 | 1000BASE-SX/LX| 2| –| 2| –| –| 1
 | 10000BASE-SX/LX/ZX| –| –| –| 2| 2| –
Downlink| VDSL2 interface| 96| –| 24| –| –| –
 | ADSL2+ interface| 128| 24| –| –| –| –
 | G.SHDSL.bis interface| –| 32| –| –| –| –
 | VoIP interface| 256| –| 24 (IES1724-58V)| –| –| –
 | G.fast interface| –| –| –| 8/16| 16| 4
QoS|  |  |  |  |  |  |
802.1p priority queue| 8| 8| 8| 8| 8| 8
802.1q tag-based VLAN| Yes| Yes| Yes| Yes| Yes| Yes
SPQ/WFQ|  | Yes| Yes| Yes| Yes| Yes| Yes
Security|  |  |  |  |  |  |
IGMP v2, v3|  | Yes| Yes| Yes| Yes| Yes| Yes
IGMP fast leave|  | Yes| Yes| Yes| Yes| Yes| Yes
Multicast VLAN|  | Yes| Yes| Yes| Yes| Yes| Yes
MLDv1 & MLDv2 snooping and proxy| Yes| –| Yes| Yes| Yes| Yes
Management|  |  |  |  |  |  |
SNMP v2c, v3|  | Yes| –| Yes| Yes| Yes| Yes
Web management| Yes| Yes| Yes| Yes| Yes| Yes
CLI management|  | Yes| Yes| Yes| Yes| Yes| Yes
EMS management| Yes| Yes| Yes| Yes| Yes| Yes
Physical specifications
Dimensions (WxDxH)(mm/in.)|  | 441.2 x 262 x 88.8/

17.37 x 10.31 x 3.5

| 440 x 320 x 44/

17.32 x 12.60 x 1.73

| 440 x 250 x 44.35/

17.32 x 9.84 x 1.75

| 440 x 250 x 44.25/

17.32 x 9.84 x 1.73

| 440 x 250 x 44.25/

17.32 x 9.84 x 1.73

| 438 x 216 x 104/

17.24 x 8.5 x 4.09

Weight (kg/lb.)|  | 3.2/7.05| 3.7/8.16| 4.7/10.36| 6.0/13.23| 6.0/13.23| 13/28.66

MSAN/DSLAM line card information

Linecard type| Model| Description| IES6217| IES5212| IES5206| IES4204| IES-6000| IES-5112| IES-5106| IES4105| IES-1000
---|---|---|---|---|---|---|---|---|---|---|---
Management

and switching cards

| MSC1324GB| Management and switching card with 2 10G and 4 GbE combo ports| |  |  |  | •| •| •|  |
MSC1324GC| Management and switching card with 2 10G and 4 GbE combo ports|  | |  |  | •| •| •|  |
 | MSC1280XB| Management card with 8 10G SFP+ open slots| •| •| •|  |  |  |  | |
 | MSC1240QA| Management card with 4 10G SFP+ open slots|  |  |  | •|  |  |  | |
 | MSC1002GA| Management card with 2 GbE combo ports|  |  |  |  |  |  |  | •|
VDSL line cards| VLC1424G-56| 24-port DMT-based VDSL2 line card, Annex A, 30a profile|  |  |  |  | •| •| •|  |
 | VLC1348G-51| 48-port DMT-based VDSL2 line card 17a profile, Annex A/Annex B|  |  |  |  | •| •| •|  |
 | VLC1348G-53| 48-port DMT-based VDSL2 line card 17a profile, Annex A/Annex B|  |  |  |  | •| •| •|  |
 | VLC1448X-51S| 48-port vectoring VDSL2 Annex A line card with built-in ETSI&ANSI POTS splitter, 17a profile| •| •| •| •|  |  |  |  |
 | VLC1448X-51F| 48-port dual-line vectoring VDSL2 Annex A line card with built-in ETSI & ANSI POTS splitter, 17a profile|  |  |  | •|  |  |  |  |
 | VLC1448X-51D| 48-port dual-line vectoring VDSL2 Annex A line card (over POTS), 17a profile|  |  |  | •|  |  |  |  |
 | VLC1448X-51| 48-port vectoring VDSL2 Annex A/B/M/J line card, 17a profile| •| •| •| •|  |  |  |  |
 | VLC1124A-51| 24-port VDSL line card, Annex A and 17a profile with built-in splitter|  |  |  |  |  |  |  | •|
ADSL line cards| ALC1372G-51| 72-port Annex A ADSL2/ADSL2+ line card (over POTS)|  |  |  |  | •| •| •|  |
 | ALC1348G-51C| 48-port Annex L and Annex M ADSL2+/VoIP combo card|  |  |  | | •| •| •|  |
 | ALC1132A-51| 32-port Annex A ADSL2/2+ line card (over POTS) with built-in splitter|  |  |  |  |  |  |  | •|
 | AAM1212-51| 12-port Annex A ADSL2/ADSL2+ module (over POTS)|  |  |  |  |  | |  |  | •
VoIP line cards| VOP1164A-61| 64-port VoIP line card. H.248 or SIP|  | |  |  |  |  |  | •|
 | VOP1372G-61 (SIP/H.248)| 72-port SIP/H.248 VoIP line card|  |  |  |  | •| •| •|  |
Vectoring line card| VEC1001X| 192-port vectoring engine card| •| •| •| |  |  |  |  |
GbE line cards| GLC1320G-55| 20-port Gigabit Ethernet SFP (1000BASE-FX, 1000BASE-BX, and 1000BASE-LX)|  |  |  |  | •| •| •|  |
 | GLC1440X-55A| Gigabit Ethernet line card with 20 GbE C-SFP/SFP open slots| •| •| •| •|  |  |  |  |
GPON line card| OLC3416-42A| GPON line card with 16 GPON SFP open slots| | •| •| •|  |  |  |  |
10G PON line card| OLC3708-43A| 10G PON line card with 8 XFP open slots| |  | •| •|  |  |  |  |
SHDSL line cards| SLC1348G-22| 48-port G.SHDSL.bis line card|  |  | |  | •| •| •|  |
 | SAM1316-22| 12-port G.SHDSL.bis extension module|  |  |  |  |  |  |  |  | •

For more product information, visit us on the web at www.zyxel.com

Copyright © 2022 Zyxel and/or its affiliates. All rights reserved. All specifications are subject to change without notice.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals