SEALEY MW180i 180-200AMP Mma Inverter Welders
IMPORTANT
NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO
DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE
WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
SYMBOLS
Refer to instruction manual. Fire hazard. Arc rays wear eye protection. Electric shock hazard. Fumes / gases Use in ventilated area
Hot surfaces wear protective gloves. Magnetic fields produced.
SAFETY
ELECTRICAL SAFETY
WARNING
It is the responsibility of the owner and the operator to read, understand and
comply with the following: You must check all electrical products, before use,
to ensure that they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure that the risk of
electric shock is minimised by the installation of appropriate safety devices.
A Residual Current Circuit Breaker RCCB should be incorporated in the main
distribution board. We also recommend that a Residual Current Device RCD is
used. It is particularly important to use an RCD with portable products that
are plugged into a supply which is not protected by an RCCB. If in any doubt
consult a qualified electrician. You may obtain a Residual Current Device by
contacting your Sealey stockist. You must also read and understand the
following instructions concerning electrical safety. The Electricity at Work
Act 1989 requires that all portable electrical appliances, if used on business
premises, are tested by a qualified electrician, using a Portable Appliance
Tester PAT at least once a year. The Health & Safety at Work Act 1974 makes
owners of electrical appliances responsible for the safe condition of those
appliances and the safety of the appliance operators. If in any doubt about
electrical safety contact a qualified electrician. Ensure that the insulation
of all cables on the appliance is safe before connecting it to the power
supply.
- Ensure that cables are always protected against short circuit and overload.
- Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose.
- Ensure that the voltage marked on the appliance matches the power supply to be used.
- DO NOT pull or carry the appliance by the power cable.
- DO NOT pull the plug from the socket by the cable.
- DO NOT use worn or damaged cables, plugs or connectors.
- Have any faulty item repaired or replaced 8 immediately by a qualified electrician.
- We recommend connection to a supply with a type C breaker.
- If in doubt you must contact a qualified electrician to ensure that a suitably rated supply is available.
WARNING
Be very cautious if using a petrol or diesel generator. The generator must be
stable with regard to frequency H3, voltage and wave form. The output must be
higher than the power kVA of the inverter. The generator must also be self
regulating. If any A.M. feature is not respected the working of the regulation
card may be affected. Use of a generator without a regulator may be dangerous
and will invalidate your inverter warranty.
GENERAL SAFETY
Operator Safety
- Operators must receive adequate training before using the inverter.
- Remove ill fitting clothing, remove ties, watches, rings and other loose jewellery and contain long hair.
- DO NOT operate the inverter while under the influence of drugs, alcohol or intoxicating medication, or if tired.
- Stand correctly keeping a good footing and balance, ensure that the floor is not slippery and wear non-slip shoes.
- Keep unauthorised persons away from the work area. Any persons working within the area must wear the same protective items.
- Avoid oily greasy clothing. A spark may ignite them.
- DO NOT touch the work piece close to the weld as it will be very hot. Allow to cool.
- DO NOT touch the electrode holder immediately after use. Allow the electrode holder to cool.
- Wear safety welding gauntlets.
Cable Connections
- Keep the inverter and cables in good working order and condition.
- Take immediate action to repair or replace damaged parts.
- Ensure that there is no obstruction to the flow of clean, cool air and ensure that there are no conductive dusts, corrosive vapours or humidity which could enter the inverter and cause serious damage.
- DO NOT weld containers or pipes which have held flammable materials – gases, liquids or solids.
DANGER
Avoid welding on materials cleaned with chlorinated solvents or near such
solvents. Vapours from chlorinated solvents such as de greasers can be
decomposed by the heat of the arc to form PHOSGENE, a highly toxic gas, and
other lung and eye irritating products. The ultraviolet (radiant) energy of
the arc can also decompose trichloroethylene and perchloroethylene vapours to
form phosgen.
- DO NOT weld where solvent vapours can be drawn into the welding or cutting atmosphere or where the radiant energy can penetrate to atmospheres containing even minute amounts of trichloroethylene or perchloroethylene. Prevent dangerous conditions arising by providing adequate ventilation.
- NEVER ventilate with oxygen.
- Lead, cadmium, zinc, mercury and beryllium-, bearing materials, when welded or cut may produce harmful concentrations of toxic fumes.
- Adequate local exhaust ventilation must be used, or each person in the area as well as the operator must wear an air supplied respirator.
- For beryllium, both must be used.
- Metals coated with or containing materials that emit toxic fumes should not be heated unless coating is removed from the work surface, the area is well ventilated, or the operator wears an air supplied respirator.
- DO NOT work in an unventilated confined space.
- If necessary, wear an air supplied respirator.
WARNING
Generator engine exhaust must be vented to the outside air. Carbon monoxide
can kill.
Protection from Arc
WARNING
Use welding head shield to protect eyes and avoid exposing skin to ultraviolet
rays given off by electric arc. Looking at an arc momentarily with unprotected
eyes (particularly a high intensity gas-shielded arc) can cause a retinal burn
that may leave a permanent dark area in the field of vision. Before welding
whilst wearing contact lenses, seek advice from your optician. Avoid
unintentional contact with workpiece. Accidental or uncontrolled arcing on the
electrode holder may be dangerous. DO NOT hit the electrode on the workpiece,
this may damage the electrode and make strike-up difficult.Wear safety welding
gauntlets. Welding Environment.
Locate the inverter in a suitable work area. Keep the work area clean and tidy
and free from unrelated materials. Also ensure that the work area has adequate
lighting. DO NOT get inverter wet or use in damp or wet locations or areas
where there is condensation. First aid facilities and a qualified first aid
person should be available during welding operations. For production welding,
a separate room or enclosed bay should be provided. In open areas, surround
the operation with low reflective, non-combustible screens or panels. Allow
for free air circulation, particularly at floor level. Provide face shields
for all persons who will be looking directly at the weld. Before starting to
weld, make sure that screen or bay doors are closed. Always ensure that there
is full free air circulating around the outer casing of the machine, and that
the louvres are unobstructed.
Fire Hazard
WARNING
Be aware that flying sparks or falling slag can pass through cracks, along
pipes, through windows or doors, and through wall or floor openings, out of
sight of the operator. Sparks and slag can fly 10m. DO NOT weld within 10
metres of combustible materials including building construction materials.DO
NOT weld adjacent to openings concealed or visible in floors or walls within
10m that can expose combustibles to sparks. DO NOT weld near to walls,
ceilings, roofs or metal partitions where there are combustibles that can be
ignited by radiant or conducted heat. Have suitable fire extinguishing
equipment available and someone to use it during welding operations and for
some time after welding ceases. After work is done, check that area is free of
sparks, glowing embers, and flames.
PRODUCT CARE & MAINTENANCE
- DO NOT attempt to fit any unapproved electrode holder, components, or parts to the inverter unit.
- Keep the inverter clean for best and safest performance.
- If the case is opened for maintenance or repair, wait 10-15 seconds after the unit is switched off for the capacitor to discharge.
INTRODUCTION
Compact and lightweight unit, suitable for arc welding and TIG using the lift start method. Unit can arc weld a variety of rods including rutile, basic and stainless from Ø1.6mm up to Ø5mm. Features thermal cut-out protection. Portability allows the welder to be taken to the job at hand, ideal for the mobile technicians. Supplied with 2m 16mm² cable with electrode holder and 2m 16mm² earth clamp and cable, both with 35-70 quick connectors. Forced air cooling system. Optional TIG accessory kit available Model No. TIG10S
SPECIFICATION
Model No. | MW180i | MW200i |
---|---|---|
Welding Current | 20-180A | 20-200A |
Duty Cycle | 100%80A | 100%89A |
60%104A | 60%115A | |
20%180A | 20%200A | |
Electrode Capacity | Ø1.6-4.0mm | Ø1.6-5mm |
Absorbed Power | 8kW | 9.2kW |
Supply | 230V | 230V |
Protection | IP21S | IP21S |
TIG Accessory Kit Optional | TIG10S Inverter TIG Welding Torch 16mm |
PREPARATION
WARNING
Ensure that the inverter is not plugged into the mains power supply before
connecting or disconnecting cables.Failure to follow the electrical safety
instructions may affect the operating performance and could damage the built-
in safety system which, in turn, could result in personal injury or fatality
and will invalidate the warranty.
WELDING CABLE ELECTRODE HOLDER CONNECTION
Before connecting cables it is important to refer to the electrode manufacturer’s instructions on the electrode packaging which will indicate the correct polarity connection for the electrode, together with the most suitable current to use.
ARC WELDING
In principle, when ARC welding the Electrode Holder POSITIVE is normally connected to the POSITIVE + terminal. The WORK CLAMP cable is connected to the terminal not occupied by the electrode holder cable. The clamp is connected toThe work piece, or A metallic work bench. The connection must be as close to the proposed weld as possible.
WARNING
Cable connectors must be turned into the quick plugs fully to ensure a good
electrical contact. Loose connections will cause overheating, rapid
deterioration and loss in efficiency. DO NOT use welding cables over 10m in
length. With the exception of a metallic workbench DO NOT connect the return
cable to any metallic structure which is not part of the workpiece, as this
will jeopardise weld quality and may be dangerous.
BACK PANEL
Rocker switch. Turns mains power on and off.
FRONT PANEL
Welding Current Control
Regulates welding current. The set value will be displayed in the display panel.
Power Indicator
Illuminates when machine is switched on ready for use.
Alarm Indicator
Illuminates when the circuitry within the machine overheats. Allowing the inverter to cool down naturally will restore operation after a period of time. See rating plate for details of duty cycle.
VRD Indicator
illuminates when the voltage reduction device is active. To operate the VRD, press the function button and hold for 2 seconds. The display will read ‘VRD’ and by turning the Welding Current control dial it can be turned On or Off.
Hot Start
function is a feature that pumps up the amperage for a short time when you start the arc. Higher amperage helps to start the arc easier without sticking the electrode to the base metal. To enable this feature, press the function button and hold for 2 seconds and VRD is displayed. Press the function button once more to engage this feature. Rotate the knob left to adjust to -10 or right to adjust to +10
Lift TIG Indicator
With Lift-Arc Ignition feature, to start the arc the tungsten electode is touched on the job and lifted off. The start- up current is very low and therefore the tungsten barely sticks to the job and the sharpened point is not damaged. The tungsten is then easily lifted off the job. The machine senses that the contact is broken and begins supplying full welding current. To enable this feature, press the function button and hold for 2 seconds, VRD will be displayed. Press the function button once more to display HS and press the downward arrow one more time to engage the Lift TIG function. Press the button again in order to exit the menu system.
ELECTRODES
Electrode Ømm | Minimum Welding Current Amps | Maximum Welding Current Amps |
---|---|---|
1.6 | 25 | 50 |
2.0 | 40 | 80 |
2.5 | 60 | 110 |
3.2 | 80 | 160 |
4.0 | 120 | 200 |
The welding current must be regulated according to the diameter of the electrode in use and the type of joint to be welded.
WELDING PROCEDURE
WARNING
Ensure that you read, understand and follow the safety instructions. Place the
welding mask in front of your face before striking the arc.
ARC WELDIN
Strike the electrode tip on the workpiece as if you were striking a match.
WARNING
DO NOT hit the electrode on the workpiece, as this may damage the electrode.
As soon as the arc is struck, maintain a distance from the workpiece equal to
the diameter of the electrode. Keep this distance as constant as possible for
the duration of the weld. As you advance along the workpiece the angle of the
electrode must be maintained at between 20º and 30º.At the finish of the weld,
bring the end of the electrode backward in order to fill the weld crater and
then quickly lift the electrode from the weld pool to extinguish the arc. Hot
metal such as electrode stubs and workpieces should never be handled without
gloves.
MAINTENANCE
WARNING
Before carrying out routine maintenance, switch off the welding and disconnect
it from the mains power supply.If the welding machine is not functioning
properly repairs should be carried out only and by authorised s ervice
engineers. Before removing the welding machine panels switch off the machine
and disconnect it from the mains power supply. Wait 10-15 seconds after the
unit is switched off for the capacitor to discharge.
- Periodically remove the casing and, with a low pressure air flow max 1bar or15psi remove dust from inside the machine.
- DO NOT direct compressed air onto the electronic circuit boards, these should be cleaned with a very soft brush.
- Ensure that all electrical connections are tight and check the wiring for damage to the insulation.
- Ensure that the casing is correctly replaced and secured before attempting to use the inverter.
- Keep the outside of the machine clean by wiping with a soft, dry cloth.
- For any other service or maintenance, contact your local Sealey service agent
TROUBLESHOOTING
- If you have a problem with the inverter, check to ensure that the following are correct:
- Check that the welding current is suitable for the diameter and type of electrode being used.
- When the mains switch is on, check that the power lamp is on.
- If this is not the case then there may be a mains supply problem.
- Check the overheat indicator has the thermal cut-out activated?
- This indicates either an over or under voltage or short circuit.
- If the thermal interrupter has activated, wait for the machine to cool down before restarting.
- Ensure that you are using the correct supply voltage.
- Check the machine output and ensure there is nothing causing a short-circuit.
- Check that all circuit connections are correct.
- In particular check that the work clamp is correctly attached to the workpiece.
- Ensure that there is no grease, paint etc. on the surface.
RATING PLATE
The rating plate on the inverter gives the following data:
- Rating of internal protection provided by casing.
- Symbol for power supply line: 1= Single-phase AC.
- Indicates that welding may be carried out in environments with a heightened risk of electric shock eg very close to large metallic objects.
- Welding procedure: manual arc welding with covered electrode
- Symbol for internal structure of the welding machine.
- Model No.
- Manufacturers Serial Number for welding machine identification.
- The EUROPEAN standard relating to the safety and construction of arc welding machines.
- Output.
- Uº: Maximum no load voltage.
- I², U²: Current and corresponding normalised voltage that the welding machine can supply during welding. X:
- Welding ratio based on a 10 minute duty cycle. 30% indicates 3 minutes welding and 7 minutes rest, 100% indicates continuous welding. A/V-A/V: Shows the adjustment for the welding current (min – max) the corresponding arc voltage.
- Power Supply
- Alternating voltage and power supply frequency of welding machine.(allowed limit ± 10%) I1 max: Maximum current absorbed by the line. I1 eff: Effective current supplied.
ELECTRONIC COMPATIBILITY
THIS EQUIPMENT IS IN CONFORMITY WITH THE EUROPEAN STANDARD ON THE ELECTROMAGNETIC COMPATIBILITY OF ARC WELDING EQUIPMENT AND SIMILAR PROCESSES (e.g. ARC AND PLASMA CUTTING
PROTECTION AGAINST INTERFERENCE E.M.C
The emission limits in this standard may not, however, provide full protection against interference to radio and television reception when the equipment is used closer than 30m to the receiving antenna. In special cases, when highly susceptible apparatus is being used in close proximity, additional mitigation measures may have to be employed in order to reduce the electromagnetic emissions. At the same time there could occur some potential difficulties in having electromagnetic compatibility in a non-industrial environment (e.g. in residential areas). Therefore it is most important that the equipment is used and installed according to the following instructions.
INSTALLATION AND USE
The user is responsible for installing and using the equipment according to these instructions. If electromagnetic disturbances are detected, then it shall be the responsibility of the user of the equipment to resolve the situation with the technical assistance of the supplier. In some cases this remedial action may be as simple as earthing the circuit.In other cases it could involve constructing an electromagnetic screen, enclosing the welding power source and the work, complete with associated input filters. In all cases the electromagnetic disturbances shall be reduced to the point where they are no longer troublesome.
NOTE
The welding/cutting circuit may or may not be earthed for safety reasons.
Changing the earthing arrangements should only be authorised by a person who
is competent to assess whether the changes will increase the risk of injury,
e.g. by allowing parallel welding/cutting circuit return paths which may
damage the earth circuits of other equipment. Further guidance is given in IEC
974-13 ’Arc Welding Equipment – Installation and Use.
ASSESSMENT OF AREA
Before installing the equipment the user shall make an assessment of potential electromechanical problems in the surrounding area. The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises. The following shall be taken into account :
- Other supply cables, control cables, signalling and telephone cables, above, below and adjacent to the welding equipment.
- Radio and television transmitters and receivers.
- Computer and other control equipment.
- Safety critical equipment, e.g. security monitoring of industrial equipment.
- The health of people in the vicinity, e.g. persons fitted with a pacemaker or hearing aid.
- Equipment used for calibration or measurement.
- The immunity of other equipment in the environment. The user shall ensure that other equipment being used in the environment is compatible. This may require additional protective measures.
- The time of day that welding and other activities are to be carried out.
RATING PLATE
The equipment should be connected to the mains supply according to these instructions. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains supply. Consideration should also be given to shielding the supply cable of permanently installed equipment in metallic conduit or equivalent. This shielding should be connected to the power source so that good electrical contact is maintained between the conduit and the welding power source enclosure.
MAINTENANCE OF THE EQUIPMENT.
The equipment should be routinely maintained according to these instructions. All access and service covers should be closed and properly fastened when the welding equipment is in operation. The welding equipment should not be modified in any way except for those changes and adjustments covered in these instructions. In particular, the spark gaps of any arc striking and stabilising devices should be adjusted and maintained according to the instructions.
CABLES
The welding/cutting cables should be kept as short as possible and should be
positioned close together, running at or close
to the floor level.
EQUIPOTENTIAL BONDING
Bonding of all metallic components in the welding/cutting installation and adjacent to it should be considered. However, metallic components bonded to the workpiece will increase the risk that the operator could receive a shock by touching these metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic components.
EARTHING OF THE WORKPIECE
Where the workpiece is not bonded to earth for electrical safety, nor connected to earth because of its size and position, e.g. ship’s hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other electrical equipment. Where necessary, the connection of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by a suitable capacitance, selected according to national regulations. Selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference. Screening of the entire welding/cutting installation may be considered for special applications.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids if applicable into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment WEEE.When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note
It is our policy to continually improve products and as such we reserve the
right to alter data, specifications and component parts without prior notice.
Important
No Liability is accepted for incorrect use of this product.
Warranty
Guarantee is 36 months from purchase date, proof of which is required for any
claim.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>