STANLEY HP12B GT & HP Power Unit Technical Bulletin Instruction Manual

June 4, 2024
Stanley

STANLEY HP12B GT & HP Power Unit Technical Bulletin Instruction Manual
STANLEY HP12B GT & HP Power Unit Technical Bulletin

What has changed?

For all non-diesel models of GT and HP Power Units, a shipping cap will be installed over the breather valve of the hydraulic oil tank.
Induction

Caution: Pump damage can occur if action is not taken! Remove the attached shipping cap and tag before using this power unit. Failure to remove the shipping cap could cause catastrophic damage.

Why has the change taken place?
During shipping, it is possible for hydraulic oil to escape the hydraulic oil reservoir through the breather valve. In order to eliminate hydraulic oil spillage, STANLEY will install a cap over the breather valve before the power unit is shipped.

How to Remove the Shipping Cap

  1. Unpack the power unit.

  2. Locate the shipping cap installed over the breather valve.
    Note: The shipping cap will be connected to a large information tag.
    Plug and Tag Installation

  3. Grasp the base of the cap, pull it off of the breather valve and discard it.
    Note: If your power unit breather valve does not have a cap installed, you may use the power unit normally

IMPORTANT: To fill out a product warranty validation form, and for information on your warranty, visitwww.stanleyinfrastructure.com and select the Company tab > Warranty.

Note: The warranty validation record must be submitted to validate the warranty.

WARNING

SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL.

REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN AUTHORIZED AND CERTIFIED DEALER.

SAFETY SYMBOLS

Safety symbols and signal words, as shown below, are used to emphasize all operator, maintenance and repair actions which, if not strictly followed, could result in a life-threatening situation, bodily injury or damage to equipment.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

Danger: This safety alert and signal word indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Warning: This safety alert and signal word indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution: This safety alert and signal word indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Caution: This signal word indicates a potentially hazardous situation which, if not avoided, may result in property damage.

Caution: This signal word indicates a situation which, if not avoided, will result in damage to the equipment.

Importance: This signal word indicates a situation which, if not avoided, may result in damage to the equipment.

Always observe safety symbols. They are included for your safety and for the protection of the tool.

LOCAL SAFETY REGULATIONS

Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and maintenance personnel.

SAFETY PRECAUTIONS

Tool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the equipment.

These safety precautions are given for your safety. Review them carefully before operating the tool and before performing general maintenance or repairs.

Supervising personnel should develop additional precautions relating to the specific work area and local safety regulations. If so, place the added precautions in the space provided.

In addition to this manual, read and understand safety and operating instructions in the engine “Operation & Maintenance Instructions” manual furnished with the HP12 power unit.

The HP12 will provide safe and dependable service if operated in accordance with the instructions given in this manual. Read and understand this manual and any stickers and tags attached to the unit. Failure to do so could result in personal injury or equipment damage.

  • Operator must start in a work area without bystanders. The operator must be familiar with all prohibited work areas such as excessive slopes and dangerous terrain conditions.
  • Establish a training program for all operators to ensure safe operation.
  • Do not operate the power unit unless thoroughly trained or under the supervision of an instructor.
  • Always wear safety equipment such as goggles, ear protection, head protection and safety shoes at all times when operating the power unit.
  • Do not inspect or clean the power unit while it is running. Accidental engagement of the unit can cause serious injury.
  • Always use hoses and fittings rated at 2500 psi/172 bar with a 4-to-1 safety factor. Be sure all hose connections are tight.
  • Be sure all hoses are connected for correct flow direction to and from the tool being used.
  • Do not inspect hoses and fittings for leaks by using bare hands. “Pin-hole” leaks can penetrate the skin.
  • NEVER OPERATE THE POWER UNIT IN A CLOSED SPACE. Inhalation of engine exhaust can be fatal.
  • Do not operate a damaged or improperly adjusted power unit.
  • Never wear loose clothing that can become entangled in the working parts of the power unit.
  • Keep all parts of your body away from the working parts of the power unit.
  • Keep clear of hot engine exhaust.
  • Do not add fuel to the power unit while it is running or is still hot.
  • Do not operate the power unit if gasoline odor is present.
  • Do not use flammable solvents around the power unit engine.
  • Do not operate the power unit within 3.3 ft/1 m of buildings, obstructions or flammable objects.
  • Do not reverse tool rotation direction by changing fluid flow direction.
  • Allow power unit engine to cool before storing in an enclosed space.
  • Always keep critical tool markings, such as labels and warning stickers, legible.
  • To avoid personal injury or equipment damage, all tool repair, maintenance and service must only be performed by authorized and properly trained personnel.

TOOL STICKERS AND TAGS

74759 Power Unit Dash Decal
TOOL STICKERS

76748 Single Circuit Decal
TOOL STICKERS

84815 Emissions Decal

HOSE TYPES

The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hydraulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with STANLEY hydraulic tools. They are:

Certified non-conductive — constructed of thermoplastic or synthetic rubber inner tube, synthetic fi ber braid reinforcement, and weather resistant thermoplastic or synthetic rubber cover. Hose labeled certified nonconductive is the only hose authorized for use near electrical conductors.

Wire-braided (conductive) — constructed of synthetic rubber inner tube, single or double wire braid reinforcement, and weather resistant synthetic rubber cover. This hose is conductive and must never be used near electrical conductors.

Fabric-braided (not certified or labeled non-conductive) —  constructed of thermoplastic or synthetic rubber inner tube, synthetic fiber braid reinforcement, and weather resistant thermoplastic or synthetic rubber cover. This hose is not certified non-conductive and must never be used near electrical conductors.

HOSE SAFETY TAGS

To help ensure your safety, the following DANGER tags are attached to all hose purchased from STANLEY. DO NOT REMOVE THESE TAGS.

If the information on a tag is illegible because of wear or damage, replace the tag immediately. A new tag may be obtained from your STANLEY Distributor.

THE TAG SHOWN BELOW IS ATTACHED TO “CERTIFIED NON-CONDUCTIVE” HOSE

HOSE TYPES
(Shown smaller than actual size)
THE TAG SHOWN BELOW IS ATTACHED TO “CONDUCTIVE” HOSE.
HOSE TYPES
(Shown smaller than actual size)

HOSE RECOMMENDATIONS

Tool to Hydraulic Circuit Hose Recommendations

The chart to the right shows recommended minimum hose diameters for various hose lengths based on gallons per minute (GPM)/liters per minute (LPM). These recommendations are intended to keep return line pressure (back pressure) to a minimum acceptable level to ensure maximum tool performance.

This chart is intended to be used for hydraulic tool applications only based on STANLEY tool operating requirements and should not be used for any other applications.

All hydraulic hose must have at least a rated minimum working pressure equal to the maximum hydraulic system relief valve setting.

All hydraulic hose must meet or exceed specifications as set forth by SAE J517.

Oil Flow| Hose Lengths| Inside Diameter| USE ( Press/Return)| Min. Working Pressure
---|---|---|---|---
GPM| LPM| FEET| METERS| INCH| MM| PSI| BAR
Certified Non-Conductive Hose – Fiber Braid – for Utility Bucket Trucks
4-9| 15-34| up to 10| up to 3| 3/8| 10| Both| 2250| 155
Conductive Hose – Wire Braid or Fiber Braid -DO NOT USE NEAR ELECTRICAL CONDUCTORS
4-6| 15-23| up to 25| up to 7.5| 3/8| 10| Both| 2500| 175
4-6| 15-23| 26-100| 7.5-30| 1/2| 13| Both| 2500| 175
5-10.5| 19-40| up to 50| up to 15| 1/2| 13| Both| 2500| 175
5-10.5| 19-40| 51-100| 15-30| 5/8| 16| Both| 2500| 175
c 5-10.5| 19-40| 100-300| 30-90| 5/8| 16| Pressure| 2500| 175
3/4| 19| Return| 2500| 175
10-13| 38-49| up to 50| up to 15| 5/8| 16| Both| 2500| 175
10-13| 38-49| 51-100| 15-30| 5/8| 16| Pressure| 2500| 175
3/4| 19| Return| 2500| 175
10-13| 38-49| 100-200| 30-60| 3/4| 19| Pressure| 2500| 175
1| 25.4| Return| 2500| 175
13-16| 49-60| up to 25| up to 8| 5/8| 16| Pressure| 2500| 175
3/4| 19| Return| 2500| 175
13-16| 49-60| 26-100| 8-30| 3/4| 19| Pressure| 2500| 175
1| 25.4| Return| 2500| 175

Hose Connections
Figure 1. Typical Hose Connections

HTMA / EHTMA REQUIREMENTS

TOOL TYPE

HTMA HYDRAULIC SYSTEM REQUIREMENTS| TYPE I| TYPE II| TYPE RR| TYPE III
---|---|---|---|---
Flow range| 4-6 GPM (15-23 LPM)| 7-9 GPM (26-34 LPM)| 9-10.5 GPM (34-40 LPM)| 11-13 GPM (42-49 LPM)
Nominal operating pressure (At the power supply outlet)| 1500 psi (103 bar)| 1500 psi (103 bar)| 1500 psi (103 bar)| 1500 psi (103 bar)
System relief valve setting (At the power supply outlet)| 2100-2250 psi (145-155 bar)| 2100-2250 psi (145-155 bar)| 2200-2300 psi (152 159 bar)| 2100-2250 psi (145-155 bar)
Maximum back pressure (At tool end of the return hose)| 250 psic (17 bar)| 250 psi (17 bar)| 250 psi (17 bar)| 250 psi (17 bar)
Measured at a max fluid viscosity of: (At minimum operating temperature)| 400 ssu (82 centistokes)| 400 ssu (82 centistokes)| 400 ssu (82 centistokes)| 400 ssu (82 centistokes)
Temperature: Sufficient heat rejection capacity to limit maximum fluid temperature to: (At maximum expected ambient temperature)| 140° F (60° C)| 140° F (60° C)| 140° F (60° C)| 140° F (60° C)
Minimum cooling capacity at a temperature difference of between ambient and fluid temps| 3 hp (2.24 kW) 40° F (22° C)| 5 hp (3.73 kW) 40° F (22° C)| 6 hp (5.22 kW) 40° F (22° C)| 7 hp (4.47 kW) 40° F (22° C)
Note: Do not operate the tool at oil temperatures above 140° F (60° C). Operation at higher temperatures can cause operator discomfort at the tool.
Filter minimum full-flow filtration| 25 microns| 25 microns| 25 microns| 25 microns
Sized for flow of at least: (For cold temp startup and maximum dirt-holding capacity)| 30 GPM (114 LPM)| 30 GPM (114 LPM)| 30 GPM (114 LPM)| 30 GPM (114 LPM)
Hydraulic fluid, petroleum based (premium grade, anti- wear, non-conductive) Viscosity (at minimum and maximum operating temps)| 100-400 ssu (20-82 centistokes)| 100-400 ssu (20-82 centistokes)| 100-400 ssu (20-82 centistokes)| 100-400 ssu (20-82 centistokes)
Note: When choosing hydraulic fluid, the expected oil temperature extremes that will be experienced in service determine the most suitable temperature viscosity characteristics. Hydraulic fluids with a viscosity index over 140 will meet the requirements over a wide range of operating temperatures.
*SSU = Saybolt Seconds Universal

CLASSIFICATION

EHTMA HYDRAULIC SYSTEM REQUIREMENTS

| | | | |
---|---|---|---|---|---
Flow range| 3.5-4.3 GPM (13.5-16.5 LPM)| 4.7-5.8 GPM (18-22 LPM)| 7.1-8.7 GPM (27-33 LPM)| 9.5-11.6 GPM (36-44 LPM)| 11.8-14.5 GPM (45-55 LPM)
Nominal operating pressure (At the power supply outlet)| 1870 psi (129 bar)| 1500 psi (103 bar)| 1500 psi (103 bar)| 1500 psi (103 bar)| 1500 psi (103 bar)
System relief valve setting (At the power supply outlet)| 2495 psi (172 bar)| 2000 psi (138 bar)| 2000 psi (138 bar)| 2000 psi (138 bar)| 2000 psi (138 bar)

Note: These are general hydraulic system requirements. See tool specification page for tool specific requirements.

OPERATION

PREPARATION FOR USE

Do not operate HP12 until you have completed the following steps:

READ THE ENGINE “OPERATING & MAINTENANCE INSTRUCTIONS” MANUAL.

CHECK ENGINE CRANKCASE OIL LEVEL

Check the oil level before starting the engine. Make sure the oil level is at the FULL MARK on the dipstick. Do not overfill. Use detergent oil classified “For Service SE, SF, SG” as specified in the engine “Operating & Maintenance Instructions” manual. See the “Operating & Maintenance Instructions” manual for oil viscosity grade.

CHECK ENGINE FUEL LEVEL
If fuel level is low, fill with unleaded gasoline (85 octane minimum).

CHECK HYDRAULIC FLUID
Ensure there is hydraulic fluid in the hydraulic oil tank. Below is a list of recommended oils.

Brand

| Biodegradable|

Description

---|---|---
CITGO| No| Hydurance AW32
AMS Oil| No| HVH 32
Exxon Mobil| No| Univis HVI26*
Exxon Mobil| No| DTE 10 Excel
Shell| No| S2 V 32
Chevron| No| Rando HDZ 32
Conoco Phillips| No| Unax AW-WR-32
Clarion (CITGO)| Yes| Green Bio 32
Exxon Mobil| Yes| EAL 224H
Chevron| Yes| Clarity AW32
Terresolve| Yes| Envirologic 132
Shell| Yes| Naturelle HF-E-32

*Recommended for extreme cold temperatures

INSTALL HYDRAULIC CONNECTIONS

STANLEY recommends you use hose lengths of 25 ft/8 m with 1/2 inch/12.7 mm inside diameter. Hoses must have a working pressure rating of at least 2500 psi/175 bar. Hose ends must have male threads compatible with H.T.M.A. quick disconnect fittings (NPT).

H.T.M.A. approved quick disconnect couplings are installed to hydraulic hoses so that the direction of oil flow is always from the male to the female coupling. Additional fittings, such as reducers or adapter fittings, are not required.

If adapter fittings are used, they must be approved steel hydraulic fittings meeting a minimum operating pressure rating of 2500 psi/172 bar. Do not use galvanized pipe fittings or black pipe fittings.

Use thread tape or pipe joint compound when installing quick disconnect couplings to hose or tool fittings. Follow the instructions furnished with the selected thread sealant.

DO NOT OVERTIGHTEN THE FITTINGS.
OVERTIGHTEN THE FITTINGS

Connect the pressure hose to the bottom (male) fitting.
Connect the return hose to the top (female) fitting.
Operation Instructions

CONTROLS

HP12 can provide one 8 GPM/30 LPM circuit, one 10 GPM/40 LPM circuit or one 12 GPM/45 LPM circuit.

STARTUP

  1. Toggle the Flow Switch to the “FLOW OFF” position.
    Note: HP12 will not start unless the Flow Switch is in the “FLOW OFF” position.

  2. Pull the choke knob out

  3. Select the desired flow using the Flow Selector Knob.

  4. Turn the Ignition Switch to the “START” position. After the engine starts, release the switch.

  5. Gradually push in the choke knob as the engine begins to idle smoothly.

  6. Allow the engine to warm up.

  7. Connect hoses and the tool.

  8. Toggle the Flow Switch to the “FLOW ON” position.

CHANGING CIRCUIT FLOW

  1. Toggle the Flow Switch to the “FLOW OFF” position
  2. Select the desired circuit flow using the Flow Selector Knob.
  3. Toggle the Flow Switch to the “FLOW ON” position.

SHUTDOWN

  1. Toggle the Flow Switch to the “FLOW OFF” position.
  2. Allow the engine to idle for approximately one minute
  3. Turn the Ignition Switch to the “OFF” position.

COLD WEATHER STARTUP

Hydraulic fluid becomes thicker in cold weather. STANLEY recommends that the engine be run at a low idle (5 GMP/20 LPM setting) long enough to bring the fluid temperature up to a minimum of 50°F/10°C. Allow the hydraulic fluid to circulate through the tool hoses until they are warm.

Once the hydraulic oil is warm, you may operate the HP12 as normal.

MAINTENANCE & TESTING

ENGINE MAINTENANCE SCHEDULE

Follow the maintenance instructions provided in the engine “Operating & Maintenance Instructions” manual.

HYDRAULIC SYSTEM MAINTENANCE

  • Check hydraulic fluid level daily and fill if needed.
  • Check hydraulic lines and fittings daily for leaks, kinks or damage. Do not use your hand to perform this check.
  • Remove condensed moisture from the hydraulic fluid:
    1. Set the flow selector to a 8 GPM/20 LPM flow.
    2. Start the engine and pump the fluid, out of the male hose fitting, into a 5 gal. container.
    3. When hydraulic tank is empty, turn the Ignition Switch to the “Off” position.
    4. Let the water settle to the bottom of the container.
    5. Pour the hydraulic fluid back into the tank, being careful to not disturb the water sitting at the bottom of the container.
  • Change the hydraulic filter every 200 hours of operation. Change more often if used in cold, moist or dusty conditions.
  • Check oil cooler. Remove debris with air pressure.

BATTERY

  • Do not charge the battery with an automotive battery charger. Charging at higher than 2 amps will damage the battery.
  • If the engine stalls during operation, set the ignition switch to the “OFF” position to preserve battery charge.

STORAGE

  • Clean the unit thoroughly. Do not pressure wash.
  • Always store the unit in a clean and dry location.
  • If storing for over 30 days, add an additive to the fuel tank to prevent the fuel from gumming. Run the engine to circulate the additive.
  • Replace crankcase oil.

GENERAL

Tests should be performed periodically to ensure HP12 is operating at maximum efficiency. STANLEY Circuit Tester ,part number 04182, can be used to isolate problems in both the engine and hydraulic system.

TESTING THE HYDRAULIC CIRCUIT

Test to ensure the hydraulic pump is supplying the correct flow and pressure, and that the system relief valve is operating properly. Before testing, make sure the engine is warm and operating smoothly.

  1. Turn the flow selector switch to the “OFF” position.
  2. Set the flow control to the flow you would like to test.
  3. Connect the STANLEY Circuit Tester to the tool hoses.
  4. Fully open the tester restrictor valve (counterclockwise).
  5. Start the engine.
  6. The test flow gauge should read +/- 1 GPM of the selected flow.
  7. Slowly turn the restrictor valve clockwise while watching the pressure gauge. The flow rate should not change as the pressure reaches 2100-2200 psi/148- 155 bar.
  8. At 2100-2200 psi/148-155 bar, the relief valve should begin to open. The flow rate should start to drop because the relief valve is allowing fluid to bypass to the hydraulic fluid tank. The relief valve is preset at the factory. If it does not open within the above range, the relief valve must be reset as follows:
  9. a. The relief valve is located on the right side of the unit, behind the dash panel (7). Use a wrench to loosen the nut on the relief valve.
  10. b. Use an Allen wrench to adjust the relief valve. Turn clockwise to raise the opening pressure, and counterclockwise to reduce the opening pressure.
  11. c. Tighten the nut and test again.

TROUBLESHOOTING

Problem

| Cause|

Remedy

---|---|---
Engine will not start.| Flow Switch is not in the “FLOW OFF” position.| Make sure the Flow Switch is in the “FLOW OFF” position before attempting to start the power unit.
Battery is not connected.| Check the battery cables for continuity and re- attach to the battery.
Weak battery charge.| Test the battery voltage and charge if necessary. If the battery will not hold a charge, replace.
No Fuel.| Ensure the power unit is cool, then add fuel.
Fuel filter is plugged.| Replace the fuel filter.
Defective spark plugs.| Remove the spark plugs and check the gap. Replace if necessary.
Hydraulic fluid is blowing out of the fluid reservoir vent.| Hydraulic fluid tank is overfilled.| Remove hydraulic fluid from the tank.
Hydraulic pump is leaking.| Check the pump connections Tighten if necessary.
The hydraulic tool connected to the power unit will not operate.| The Flow Selector Knob is not in the proper position for the connected tool.| Ensure that the Flow Selector Knob is positioned for the correct fluid flow for your tool.
The tool is not properly connected to the power unit.| Check the connection hoses   from the power unit to the tool. Ensure the pressure and the return hoses are in the proper ports on the tool.
The    quick   disconnect   fittings   are defective.| Disconnect the fittings from the hose and ensure there is free flow from each end of the fittings.
The hydraulic fluid level in the reservoir is too low.| Check the fluid level in the hydraulic fluid tank. Add more fluid if necessary.
The pump coupling is defective.| Power down the unit and check the coupling between the hydraulic pump and the engine (4).
The relief valve is stuck open.| Adjust the valve or replace if necessary (7).
Suction hoses are kinked.| Visually check the suction hose for a kink. The hose should have a smooth curve.
The solenoid is not working.| Check electrical connections Replace if necessary.
The attached tool is defective.| Refer to the tool manual.

SPECIFICATIONS

  • Engine: 23 hp Briggs
  • Capacity: One 8 GPM/30 LPM Circuit, One 10 GPM/40 LPM or One 12 GPM/50 LPM Circuit
  • Length: 36 in. / 91.4 cm
  • Width: 23 in: / 58.4 cm
  • Height: 29.5 in. / 74.9 cm
  • Weight (Wet): Single Circuit Briggs: 330 lbs / 149.6 kg
  • Fuel Tank Capacity: 5.5 gal. / 20.8 ltr
  • Estimated Gas Consumption Per Hour: 1.3 gal / 4 ltr
  • Hydraulic Reservoir Capacity: 3 gal. / 11 ltr
  • Relief Valve setting: 2100 psi / 145 bar
  • Full relief setting: 2500 psi / 172 bar
  • HTMA Category: “D” (30 LPM @ 138 bar) or “E” (45 LPM @ 138 bar) .
  • Nominal Pressure: 1500 psi/103 bar
  • Max Pressure: 2000 psi/138 bar

POWER UNITS,TRACHORSE & GAS/FUEL DRIVEN EQUIPMENT: A1. Federal Emission Component Compliance 40CFR part 1060.120 STANLEY warrants all fuel system emission components for 2 years from the date of original purchase provided there has been no abuse, neglect, modifications or improper maintenance.

Components Covered: The emission-related warranty covers all components whose failure would increase the evaporative emissions. Your emission-related warranty does not cover components whose failure would not increase evaporative emissions. Coverage under this warranty extends only to the following parts; fuel tank, fuel cap, fuel hose and vapor hose from the fuel tank to the engine and any connectors that are apart of the fuel system.

The equipment is designed, built, and equipped so it conforms at the time of sale to the ultimate purchaser and each subsequent purchaser and is in compliance with 40 C.F.R. 1060.120 standards.  The equipment is free from defectsin materials and workmanship that may keep it from meeting these requirements.

HP12 FRAME PARTS ILLUSTRATION

FRAME PARTS

ITEM #

| PART #| QTY|

DESCRIPTION

---|---|---|---
1.| 76755| 1| Frame Weldment
2.| 59075| 2| Hex Flange Bolt
3.| 59079| 1| Cooler Guard
4.| 59095| 2| Hex Flange Nut
5.| 60945| 2| Washer
6.| 15476| 2| Hex Head Capscrew – Use if hydraulic oil tank was manufactured BEFORE 1/1/2021.
| 14903| 2| Hex Head Capscrew – Use if power unit or hydraulic oil tank was manufactured AFTER 1/1/2021
7.| 23530| 2| Rear Hex Flange Bolt
8.| 03906| 7| Locknut – Model HP12B Only
9.| 370502| 7| Hex Head Capscrew
10.| 62268| 2| Lift Handle
11.| 62267| 1| Rear Lift Handle
12.| 58916| 1| Handle Lock

HP12 CONTROL PANEL ILLUSTRATION

CONTROL PANEL

ITEM #

| PART #| QTY|

DESCRIPTION

---|---|---|---
1.| 74759| 1| Dash Decal
2.| 62298| 1| Choke Cable Assembly
3.| 60959| 1| Directional Valve with Cap
4.| 60958| 1| Solenoid Coil
5.| 08104| 2| Hollow Hex Plug
6.| 76711| 1| Manifold
| 76722| | Manifold Assembly (Items 3-7)
7.| 59131| 1| Relief Valve
8.| 58856| 1| 3/8in. Female Coupler, -8 SAE
9.| 58857| 1| 3/8in. Male Coupler, -8 SAE
10.| 60962| 4| Capscrew
11.| 76748| 1| Single Circuit Decal
12.| 60955| 1| 2 Position Rotary Switch
13.| 67899| 1| 3 Position Rotary Switch
14.| 60946| 1| Hour Meter
15.| 204332| 1| Throttle Knob
16.| 76705| 1| Throttle Adjustment Plate
17.| 76791| 3| Setscrew
18.| 76702| 3| Socket Head Cap Screw
19.| 76785| 2| Shoulder Bolt
20.| 12175| 8| Washer
21.| 02259| 4| Washer
22.| 00719| 2| Nut
23.| 76779| 1| Outer Throttle Plate Assembly
24.| 02146| 2| Hex Head Cap Screw
25.| 76700| 1| Inner Throttle Plate
26.| 20334| 1| Nut
27.| 210854| 1| Ball Detent
28.| 01214| 1| Washer
29.| 00038| 2| Nut
30.| 00046| 2| Washer
31.| 208887| 1| Throttle Cable Assembly
32.| 76710| 1| Wire Harness (see page 22)

HP12 ENGINE ILLUSTRATION – FRONT

PRODUCT FRONT OVERVIEW

ITEM #

| PART #| QTY|

DESCRIPTION

---|---|---|---
1.| 59074| 2| Flange Bolt
2.| –| –| Provided as Part of Engine
3.| 59095| 3| Nut
4.| 59091| 1| Oil Cooler
5.| 59077| 1| Hydraulic Oil Tank
6.| 59080| 1| Front Grille
7.| 17821| 4| Button Head Capscrew
8.| 80986| 4| Hex Head Capscrew
9.| 80984| 4| Lock Washer
10.| 65107| 1| Blower Wheel
11.| 00111| 3| Capscrew
12.| 65108| 1| Blower Hub
13.| 20990| 1| Key
14.| 59076| 1| Bushing
15.| 62296| 2| Weather Strip
16.| 59083| 1| Blower Housing
17.| 40433| 5| Flange Bolt
18.| 26831| 2| Washer
19.| 01213| 2| Hex Head Capscrew
20.| 51292| 1| Standard Thread Union
21.| 60774| 1| Hose Clamp
22.| 59075| 1| Flange Bolt
23.| 64937| 1| Grip Plate
24.| 43687| 2| Capscrew
25.| 40080| 1| Filter Assembly
26.| 66215| 1| Cooler Mount

HP12 ENGINE ILLUSTRATION BACK
PRODUCT BACK VIEW

ITEM #| PART #| QTY|

DESCRIPTION

---|---|---|---
1.| 66214| 1| Heat Shield
2.| 36152| 2| Hex Washer Screw
3.| 56655| 1| Pump Mount
4.| 56656| 1| Coupling
5.| 07819| 1| Square Key
6.| 62385| 2| Stud
7.| 31765| 1| Pressure Switch
8.| 69387| 1| 1/8in NPT Elbow Fitting
9.| 40433| 4| Flange Bolt
10.| 01459| 4| Washer
11.| 07860| 4| Hex Head Capscrew
12.| 81743| 1| Pump
13.| 73050| 1| Fuel Tank
14.| 04303| 1| Battery
15.| 60921| 1| Battery Cover
16.| 60945| 1| Washer
17.| 15476| 1| Hex Head Cap Screw
18.| 71794| 1| Fuel Tank Cap
19.| 60920| 2| Grommet
20.| 60919| 1| Fuel Elbow
21.| 62289| 1| Fuel Hose
22.| 72317| 2| Hose Clamp
23.| 72571| 1| Fuel Vapor Hose
24.| 72451| 3| Hose Clamp
25.| 350104| 1| Connector
26.| 18893| 2| Flange Nut
27.| 371503| 1| Nut

HP12 ENGINE ILLUSTRATION – BASE
PRODUCT BASE VIEW

ITEM #

| PART #| QTY|

DESCRIPTION

---|---|---|---
1.| 76721| 1| Engine
2.| 12787| 4| Flange Nut
3.| 58897| 1| Frame Base Weldment
4.| 58976| 4| Flange Bolt
5.| 58975| 2| Foot
6.| 56633| 2| Wheel and Tire – Model HP12B Only
7.| 21318| 2| Washer – Model HP12B Only
8.| 31240| 2| Retaining Ring – Model HP12B Only
9.| 21714| 2| Handle Bumper – Model HP12B Only
10.| 58917| 1| Axle – Model HP12B Only
11.| 18893| 2| Flange Nut
12.| 58942| 4| Flange Bolt
13.| 24287| 1| Hose Clamp
14.| 01212| 1| Pipe Plug

HOSES, FITTINGS AND CLAMPS

FITTINGS AND CLAMPS

ITEM #

| PART #| QTY|

DESCRIPTION

---|---|---|---
1.| 58943| 1| Hose
2.| 62199| 4| Hose Clamp
3.| 69384| 4| Hose Clamp
4.| 69383| 2| Hose
5.| 40364| 2| 45° Elbow Fitting
6.| 59105| 1| Hose Barb
7.| 59089| 1| Hose
8.| 59088| 1| Hose
9.| 58569| 1| 90° Elbow Fitting
10.| 350000| 1| 45° Fitting
11.| 02773| 1| Adapter
12.| 350104| 1| Connector

MAIN WIRING HARNESS

PART NUMBER 76710
WIRING HARNESS

ELECTRICAL SCHEMATIC
ELECTRICAL SCHEMATIC

Support

STANLEY Infrastructure
6430 SE Lake Road
Portland, Oregon 97222 USA
503-659-5660 / Fax 503-652-1780
www.stanleyinfrastructure.com

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals