CDC-42703-1A Arrowg+ard Blue Plus Three-Lumen CVC Instructions

June 4, 2024
Arrow

CDC-42703-1A Arrowg+ard Blue Plus Three-Lumen CVC

CDC-42703-1A Arrowg+ard Blue Plus Three-Lumen CVC

Arrowg+ard Blue Plus® Three-Lumen CVC

INTRODUCTION

  • Arrowg+ard Blue Plus®1 Three-Lumen Catheter: 7 Fr. (2.5 mm OD) x 16 cm
  • Spring-Wire Guide, Marked: .032″ (0.81 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
  • Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
  • Injection Needle: SafetyGlide™2 25 Ga. x 1″ (2.54 cm)
  • Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
  • Pressure Transduction Probe
  • Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
  • Injection Needle: SafetyGlide™2 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
  • Syringe: 3 mL Luer-Lock
  • Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
  • 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
  • 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint
  • SecondSite™ Adjustable Hub: Fastener
  • SecondSite™ Adjustable Hub: Catheter Clamp
  • SharpsAway® Disposal Cup
  • SharpsAway® II Locking Disposal Cup
  • Maximal Barrier Drape™ with 4″ fenestration
  • Needle Holder
  • Safety Scalpel: #11
  • Checklist/CLIP Sheet
  • Sterile Procedure Sign
  • Medication Label: 1% Lidocaine
  • Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
  • Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
  • Surgical Apparel: Impervious Gown
  • Surgical Apparel: Bouffant Cap
  • Surgical Apparel: Mask with Eye Shield
  • Suture: 3-0 Silk with Curved Needle
  • HemoHopper® Fluid Receptacle
  • Licensed under US Patent No. 7,329,412.
  • A trademark of Becton, Dickinson and Company.
  • A registered trademark of CareFusion or one of its subsidiaries.

CDC-42703-1A

CDC-42703-1A Arrowg+ard Blue Plus Three-Lumen CVC-1

Not made with natural rubber latex.
Store between 20 – 25°C (68 – 77°F).
Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and
corresponding medication.
Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine,
silver sulfadiazine and/or sulfa drugs.

Priming volumes are approximate and are done without accessories.
† Flow rate values are approximate and are determined using deionized water at 100 cm head height.