CDC-42703-1A Arrowg+ard Blue Plus Three-Lumen CVC Instructions
- June 4, 2024
- Arrow
Table of Contents
CDC-42703-1A Arrowg+ard Blue Plus Three-Lumen CVC
Arrowg+ard Blue Plus® Three-Lumen CVC
INTRODUCTION
- Arrowg+ard Blue Plus®1 Three-Lumen Catheter: 7 Fr. (2.5 mm OD) x 16 cm
- Spring-Wire Guide, Marked: .032″ (0.81 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
- Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
- Injection Needle: SafetyGlide™2 25 Ga. x 1″ (2.54 cm)
- Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
- Pressure Transduction Probe
- Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
- Injection Needle: SafetyGlide™2 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
- Syringe: 3 mL Luer-Lock
- Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm
- 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
- 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®3 One-Step Solution with Hi-Lite Orange™ Tint
- SecondSite™ Adjustable Hub: Fastener
- SecondSite™ Adjustable Hub: Catheter Clamp
- SharpsAway® Disposal Cup
- SharpsAway® II Locking Disposal Cup
- Maximal Barrier Drape™ with 4″ fenestration
- Needle Holder
- Safety Scalpel: #11
- Checklist/CLIP Sheet
- Sterile Procedure Sign
- Medication Label: 1% Lidocaine
- Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
- Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
- Surgical Apparel: Impervious Gown
- Surgical Apparel: Bouffant Cap
- Surgical Apparel: Mask with Eye Shield
- Suture: 3-0 Silk with Curved Needle
- HemoHopper® Fluid Receptacle
- Licensed under US Patent No. 7,329,412.
- A trademark of Becton, Dickinson and Company.
- A registered trademark of CareFusion or one of its subsidiaries.
CDC-42703-1A
Not made with natural rubber latex.
Store between 20 – 25°C (68 – 77°F).
Arrow International provides the enclosed medication label(s) for your
convenience. Please ensure that these labels are applied to the correct
syringe and
corresponding medication.
Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is
contraindicated for patients with known hypersensitivity to chlorhexidine,
silver sulfadiazine and/or sulfa drugs.
Priming volumes are approximate and are done without accessories.
† Flow rate values are approximate and are determined using deionized water at
100 cm head height.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>