SEALEY IR16 Industrial Infrared Diesel Heater
IMPORTANT
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR
THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE
FOR FUTURE USE.
SYMBOLS
Refer to instructions Wear protective gloves Always unplug before servicing
and checking Warning Hot surfaces Do not cover Keep in dry area protect from
rain
Use in well ventilated areas.
ELECTRICAL SAFETY
WARNING
It is the user’s responsibility to check the following
- Check all electrical equipment and appliances to ensure that they are safe before using.
- Inspect power supply leads, plugs and all electrical connections for wear and damage.
- Sealey recommend that an RCD Residual Current Device is used with all electrical products.
- You may obtain an RCD by contacting your local Sealey stockist.
- If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT Portable Appliance Test tested.
- Electrical safety information, it is important that the following information is read and understood.
- Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
- Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
Important
Ensure that the voltage rating on the appliance suits the pow er supply to be
used and that the plug is fitted with the correct fuse – see fuse rating in
these instructions.
- DO NOT pull or carry the appliance by the power cable.
- DO NOT pull the plug from the socket by the cable.
- DO NOT use worn or damaged cables, plugs or connectors.
- Ensure that any faulty item is repaired or is replaced immediately by a qualified electrician.
- This product is fitted with a BS1363/A 13 Amp 3 pin plug.
- If the cable or plug is damaged during use, switch off the elec tricity supply and remove from use.
- Ensure that repairs are carried out by a qualified electrician.
- Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug.
- If in doubt contact a qualified electrician.
- Connect the GREEN/YELLOW earth wire to the earth terminal E.
- Connect the BROWN live wire to the live terminal L.
- Connect the BLUE neutral wire to the neutral terminal N.
- Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
- Sealey recommend that repairs are carried out by a qualified el ectrician.
- If an extension reel is used it should be fully unwound before connection.
- A reel with an RCD fitted is preferred since any appliance plugged into it will be protected.
- The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of 2.5mm² section cable.
GENERAL SAFETY
WARNING
THIS HEATER IS FOR PROFESSIONAL USE. IT HAS BEEN CAREFULLY DESIGNED FOR MOBILE
AND TEMPORARY PROFESSIONAL APPLICATIONS.
IT HAS NOT BEEN DESIGNED FOR DOMESTIC USE NOR FOR COMFORT HEATING AND SHOULD
NEVER BE USED TO HEAT CLOSED ROOMS WITHOUT ADEQUATE VENTILATION.
DANGER
Risk of carbon monoxide poisoning. Failure to provide proper ventilation could
result in serious illness or death.
- Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
- Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
- Only use diesel or kerosene to fuel this heater, in accordance with instructions contained in this manual.
- Locate heater on a level and stable surface.
WARNING
Only use heater in well ventilated areas. Ensure continuous ventilation is
provided to the heater operating area via windows and doors etc. If people are
not required to be present in the heated area, the volume of air to be heated
m³/heat o utput kW ratio must be at least 10:1 and people must be advised not
to remain in the heated area for prolonged periods. If people are required to
be present in the heated area, the volume of air to be heated (m³)/heat output
(kW) ratio must be at least 30. Ventilation must be to the outside of the
premises in which the heater is to be operated. The total open area (m²) must
be at least 0.003 times the total heat output (kW). The volume concentration
of oxygen O in the heated room, must always remain above 17%.
- DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
- DO NOT stand or place any object less than 3m from the heater output and keep the heater a minimum of 2m from any walls or objects.
- DO NOT use the heater in closed rooms, living areas, basements or below ground level.
- DO NOT allow untrained persons to operate the heater and DO NOT operate the heater without the safety guard.
- DO NOT move or handle the heater when hot, without wearing protective gloves.
- Never move the heater whilst it is operating.
- DO NOT leave the heater unattended for prolonged periods of time when in use.
- Switch the heater off and unplug from the mains before leaving work area.
- DO NOT fill the fuel tank whilst the heater is running or still hot.
- DO NOT over fill the fuel container.
- Wipe up any spilt fuel immediately.
- DO NOT obstruct the air inlet rear and air outlet front of the heater and DO NOT use duct work in front or at the rear of the heater.
- DO NOT allow children or animals near the heater when in use, or whilst still hot.
WARNING
RISK OF ELECTRIC SHOCK. DO NOT expose the heater to water spray, rain,
dripping water or wind.
- DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
- DO NOT touch the heater outlet or cone when in use, or for a period o f time after it’s switched off, as these are VERY hot and will take time to cool down.
- DO NOT switch the heater off by disconnecting it from the mains.
- ALWAYS set the switch on the burner to the OFF position and allow the cooling cycle to finish, before disconnecting from the mains.
- DO NOT use an external fuel tank. Only use the tank that is fitted to the heater, and only fill it when the heater has cooled down.
- Ensure that the heater is correctly turned off
- When not in use for an extended period, store in a safe, dry ar ea, out of reach of children.
Important
This appliance is not intended for persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be
supervised to ensure that they DO NOT play with the appliance.
INTRODUCTION
Versatile and compact diesel-fuelled Infrared technology heaters have no electric fan, meaning there is no air movement and the heat is spread evenly in all directions, quietly and dust free. Ideal for use in well ventilated indoor areas including garages, workshops, warehouses and marquees. Extremely inexpensive to run, using only around 1ltr of fuel per hour. Equipped with advanced safety features including overheat protection, auto misfire, tilt, shock, low fuel shut-off sensors and flame-out fuel cut. Features 24hr timer and temperature control thermostat. Softtouch control panel with LED display. Fitted with 4 castor wheels for easy manoeuvrability.
SPECIFICATION
- Model No:IR13 / IR16
- Electrical Plug Type: 3 Pin BS
- Fuel Tank:50L
- Fuel:Diesel
- Output (IR13/IR16):44,500 (13kW) / 55,000btu/hr (16kW)
- Heated Area (IR13/IR16):11,477ft3(325m3) /14,125ft3(400m3)
- Running Time per Filling (IR13/IR16):52hr / 42hr
- Supply:230V~50Hz
- Transport Wheels: Yes
Pannel Description
ITEM | DESCRIPTION |
---|---|
1 | LED Display for Current Temp/Set Temp-Time |
2 | Temperature Control Mode On |
3 | Cycle Time Control Mode On |
4 | (IR Receiver NOT FITTED TO THIS MODEL) |
5 | ON/OFF |
6 | Temp / Cycle Time Selection |
7 | Increase/Decrease Temp or Cycle Time Setting |
8 | Lock Settings press to lock, press to unlock |
9 | Timer ON/OFF |
10 | Timer ON Indicator |
11 | Misfire Indicator |
12 | Operating Indicator |
13 | Fuel Gauge Display |
14 | Overheating Indicator |
15 | Tilt Indicator |
16 | Low/Empty fuel Indicator |
17 | Lock State Indicator |
OPERATION
Connect the unit to the power supply and turn it on. The LED displays the current ambient temperature.
TEMPERATURE CONTROL
Temperature is displayed in degrees centigrade. To change to Fahrenheit hold both UP and DOWN arrows for 5 seconds. Switch the unit on The heater will start up using the last entered values of temperature and time. The unit can be switched off by pressing the ON/OFF button again To set the required temperature, use the UP and DOWN arrows. The temperature setting range is from 0o to 40o C.
NOTE
If the set temperature is 2oC higher than current ambient temperature the unit
will start working. If set temperature is 1oC below current ambient
temperature, the unit will stop working.
CYCLE TIME CONTROL
Switch the unit on . The heater will start up using the last entered values of temperature and time. The unit can be switched off by pressing the ON/OFF button again .Press Temp/Time selector and wait a few seconds unti l Cycle Timer ON indicator is illuminated.To set ON cycle time period, use the UP and DOWN arrows . Once set to the required value, stop pressing buttons and after 3 seconds the displayed value will be set. The cycle time ON value can be set from 5 minutes up to 55 minutes.
NOTE
If the inputted value exceeds 55 minutes, the unit will operat e in
continuous mode and displays
TIMER
- To run for a set time, select the TIMER function and use the UP and DOWN arrows to set time.
- The Timer ON indicator will illuminate.
- Long press the timer button TIMER for 3 seconds to turn off the timer.
CHILD LOCK
Press the child lock button for 3 seconds to turn on or turn off t he child lock function.
MAINTENANCE
WARNING
Unplug unit from mains power supply ensure heater is cold before opening or
servicing heater. DO NOT tamper with the unit, have an experienced service
engineer make any necessary adjustment or repairs.
LONG TERM STORAGE
- Unscrew the fuel cap.
- Using an approved siphon, remove the diesel.
- Using a small amount of diesel, rinse and swirl the fuel inside the fuel tank.
- Empty the tank completely.
NOTE
Never mix water with fuel, it will cause rust inside the tank.
IMPORTANT
Never store leftover fuel between seasons, using old fuel can damage heater.
Store Heater in a dry, well ventilated area. Be sure that the storage area is
free o f dust and corrosive vapours. Repack the heater in the original
packaging and keep user’s manual in an easily accessible place.
FUEL / FUEL TANK
Flush tank every 200 hours of operation or as needed. DO NOT flush with water, use fresh paraffin (to flush NOT to fuel) only.
NOZZLES
- Nozzles should be cleaned or replaced at least once per heating season. Contaminated fuel could make this necessary immediately.
- To clean dirt from nozzle, blow compressed air through nozzle front. it may be necessary to soak nozzle in clean paraffin or diesel to help loosen any particles.
FLAME SENSOR
The photocell should be cleaned at least once per heating season or more depending on conditions, use a cotton swab and water or alcohol to clean the lens of the photocell. Ensure the sensor is fully engaged when replacing it.
FILTERS
The fuel filter and oil filter should be cleaned at least twice p er heating season by rinsing it in clean paraffin or diesel. Contaminated or old fuel could make cleaning necessary immediately.
TROUBLESHOOTING
Error Code | Cause | Solution |
---|---|---|
Er01 | Temperature sensor open or error | Retighten connections |
Er02 | Tipping over beyond 15o | Disconnect power supply and adjust levels |
Er04 | Fire sensor connection | Retighten connections |
Er05 and
Misfire light
| Air in fuel line| Restart
No fuel| Check fuel levels
Filter clogged| Clean / change filter
Motor failure| Return to Supplier for Service
Ignitor failing
Pump failure
Er06| Temperature overheating| Check unit is not covered
Er09| Oil level sensor fault| Retighten connections
Overheating| Set temperature is below ambient| Adjust temperature setting
Athough our heaters operate with diesel fuel, when the temperatures are below 0°C, diesel additives are required to maintain the diesel’s viscosity. Typically diesel can cloud in freezing conditions and will start to gel. You will need additives for your fuel in these conditions. Kerosene does not start to gel until the ambient temperature is around -40°C.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE. When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Note
It is our policy to continually improve products and as such we reserve the
right to alter data, specifications and component parts without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty
Guarantee is 12 months from purchase date, proof of which is required for any
claim.
Note
It is our policy to continually improve products and as such we reserve the
right to alter data, specifications and component parts without prior notice.
Important
No Liability is accepted for incorrect use of this product.
Warranty
Guarantee is 12 months from purchase date, proof of which is required for any
claim.
Information requirements for gaseous/liquid fuel local space heaters
Model identifiers: IR13.V1
Indirect heating functionality: Yes| No| | | | |
Direct heat output: 13 (kW)| Indirect heat output| N/A| kW|
Fuel| Space heating emissions
NOx nitrogen oxides
Select fuel type:| Gaseous| Liquid| Specify: Diesel| 127.37| mg/kWhinput GCV
Item| Symbol| Value| Unit| Item| Symbol| Value| Unit
Heat output| Useful efficiency (NCV)
Nominal heat output| Pnom| 13| kW| Useful efficiency at nominal heat output|
ῃth,nom| 91.4| %
Minimum heat output indicative| Pmin| N/A| kW| Useful efficiency at minimum
heat output (indicative)| ῃth,min| N/A| %
Auxiliary electricity consumption| Type of heat output/room temperature
control select one
At nominal heat output| elmax| 0.08| kW| Single stage heat output, no room
temperature control| Yes No
At minimum heat output| elmin| 0| kW| Two or more manual stages, no room
temperature control| Yes No
In standby mode| lSBe| 0.0016| kW| With mechanical thermostat room temperature
control| Yes
No
Enter figure or NA| With electronic room temperature control| Yes No
With electronic room temperature control plus day timer| Yes No
With electronic room temperature control plus week timer| Yes No
Other control options multiple selections possible
Room temperature control, with presence detection| Yes No
Room temperature control, with open window detection| Yes No
With distance control option| Yes No
With adaptive start control| Yes No
Permanent pilot flame power requirement| With working time limitation| Yes
No
Pilot flame power required (if applicable)*| P pilot| N/A| kW| With
black bulb sensor| Yes No
The seasonal space heating energy efficiency
Item| Symbol| Value| Unit
The seasonal space heating Energy efficiency in active mode| ƞs,on| 100.0| %
The seasonal space heating energy efficiency| ƞs| 91.4| %
Energy efficiency classes| A
Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St
Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk
v1| | | | | | ERP Table 1
Model identifiers:IR16.V1
Indirect heating functionality: Yes| No| | | | |
Direct heat output: 16 kW| Indirect heat output:| N/A| kW|
Fuel| Space heating emissions
NOx nitrogen oxides
Select fuel type:| Gaseous| Liquid| Specify: Diesel| 122.30| mg/kWhinput GCV
Item| Symbol| Value| Unit| Item| Symbol| Value| Unit
Heat output| Useful efficiency NCV
Nominal heat output| P nom| 16| kW| Useful efficiency at nominal heat
output| ῃth,nom| 91.7| %
Minimum heat output indicative| P min| N/A| kW| Useful efficiency at
minimum heat output (indicative)*| ῃth,min| N/A| %
Auxiliary electricity consumption| Type of heat output/room
temperature control (select one)
At nominal heat output| elmax| 0.08| kW| Single stage heat output, no room
temperature control| Yes No
At minimum heat output| elmin| 0| kW| Two or more manual stages, no room
temperature control| Yes No
In standby mode| elSB| 0.0016| kW| With mechanical thermostat room temperature
control| Yes
No
Enter figure or NA
| With electronic room temperature control| Yes No
With electronic room temperature control plus day timer| Yes No
With electronic room temperature control plus week timer| Yes No
Other control options multiple selections possible
Room temperature control, with presence detection| Yes No
Room temperature control, with open window detection| Yes No
With distance control option| Yes No
With adaptive start control| Yes No
Permanent pilot flame power requiremen t| With working time limitation|
Yes No
Pilot flame power required (if applicable)| Ppilot| 0| kW| With black bulb
sensor| Yes No
The seasonal space heating energy efficiency ƞs
Item| Symbol| Value| Unit
The seasonal space heating Energy efficiency in active mode| ƞs,on| 100| %
The seasonal space heating energy efficiency ƞs| ƞs| 91.7| %
Energy efficiency classes| A
Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St
Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk
v1| | | | | | ERP Table 1