AK-45802-SK Arrowg+ard Blue Plus Two-Lumen CVC Instructions
- June 4, 2024
- Arrow
Table of Contents
45802-SK Arrowg+ard Blue Plus Two-Lumen CVC
Instructions
Arrowg+ard Blue Plus® Two-Lumen CVC
Contents:
1: Arrowg+ard Blue Plus®1 Two-Lumen Catheter: 8 Fr. (2.8 mm OD) x 20 cm
1: Spring-Wire Guide, Marked: .032″ (0.81 mm) dia. x 23-5/8″ (60 cm) (Straight
Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer
Needle
1: Injection Needle: 25 Ga. x 1″ (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x
1-1/2″ (3.81 cm)
1: Pressure Transduction Probe
1: Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson
Spring-Wire Introduction Syringe
1: Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
1: Syringe: 3 mL Luer-Lock
1: Tissue Dilator: 9 Fr. (3.0 mm) x 10.2 cm
1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep
1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with Hi-
Lite OrangeTM Tint
2: Dust Cap: Non-Vented
1: SecondSiteTM Adjustable Hub: Fastener
1: SecondSiteTM Adjustable Hub: Catheter Clamp
1: SharpsAway® II Locking Disposal Cup
1: SharpsAway® Disposal Cup
1: Drape: 41″ x 50″ with 4″ fenestration, with adhesive
1: Safety Scalpel: #11 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
1: Suture: 3-0 Braided Silk with Straight Needle
1Licensed under US Patent No. 7,329,412.
2A registered trademark of CareFusion or one of its subsidiaries.
Rx only Warning: Read all package insert warnings, precautions, and
instructions prior to use. Failure to do so may result in severe patient
injury or death. California Prop. 65 WARNING: Cancer and Reproductive
Harm. www.P65Warnings.ca.gov
Not made with natural rubber latex.
Store between 20 25°C (68 77°F).
Sterilized using ethylene oxide unless otherwise indicated in the contents
list.
Fluid path components are non-pyrogenic.
Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is
contraindicated for patients with known hypersensitivity to chlorhexidine,
silver sulfadiazine, and/or sulfa drugs.
Lumen | Priming Volume* (mL) | Gravity Flow Rate (mL/hr) |
---|
Distal (14 Ga.)
Proximal (14 Ga.)| 0.73
0.75| 5354
3984
- Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height.
Arrow International LLC
A subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd.
Morrisville, NC 27560 USA
LBL051353 R00 (2021-11)
www.teleflex.com
AK-45802-SK
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>