audio-technica AT-OC9XEB Dual Moving Coil Cartridge User Manual

June 5, 2024
Audio-Technica

audio-technica-logo

audio-technica AT-OC9XEB Dual Moving Coil Cartridge

audio-technica-AT-OC9XEB-Dual-Moving-Coil-Cartridge

Thank you for purchasing this Audio-Technica product. Before using the product, read through this user manual to ensure that you will use the product correctly. Please keep this manual for future reference.

Safety precautions

  • Keep the plastic bag provided with the product out of the reach of small children and away from open flames to avoid accidents or fire.
  • Keep the product out of the reach of small children to avoid accidents or malfunction.
  • Do not put the product in a location where it is exposed to direct sunlight, near heating devices, or in places with high temperatures, high humidity, or high concentrations of dust to avoid malfunction.
  • Do not touch the product’s cantilever, stylus tip, and magnets to avoid malfunction.
  • Do not attempt to disassemble or modify the product to avoid malfunction.
  • Do not subject the product to strong impact to avoid malfunction.

Name of each part

Become familiar with each part before using the product.

  1. Stylus tip
  2. Cantilever
  3. Output terminals
  4. Cartridge body

audio-technica-AT-OC9XEB-Dual-Moving-Coil-Cartridge-1

How to use

Mount the product onto your headshell.

  1. Mount the product onto the headshell or headshell-integrated tonearm. a
    • Mount the cartridge with the protector on to avoid damaging the cantilever and the stylus tip.
    • Temporarily tighten the screws.
  2. Connect the lead tips, noting output polarity. a
    • Connect headshell lead tips to the product output terminals (as shown in the figure).
    • Never apply heat (from solder, etc.) to the output terminals.
  3. Determine the correct position for installing the product (adjust overhang). b
    • Adjust overhang following the instructions in the tonearm’s, turntable’s, or headshell’s user manual. If you are unsure, align the stylus tip to the cartridge originally attached to the tonearm (as shown in the figure).
    • Finish tightening screws, making sure there is a balance between left and right.
  4. Adjust tracking force.
    • Confirm the tracking force for the product in “Specifications.”
    • Do not apply stylus pressure unnecessarily. It may not only damage the record and stylus but impair audio quality.
  5. Adjust tonearm height.
    • Adjust the height so that the bottom surface of the headshell and the record surface are parallel, as seen from the side. An improper tonearm height may cause the body of the product to make contact with the record and could impair audio quality or damage the record.

audio-technica-AT-OC9XEB-Dual-Moving-Coil-Cartridge-2

audio-technica-AT-OC9XEB-Dual-Moving-Coil-Cartridge-3

You need a transformer, head amplifier, or standalone phono equalizer to connect to a preamplifier/amplifier. If the preamplifier/amplifier has a phono input (MC position), it may be used as it is. However, to fully take advantage of this product’s audio quality, using a step~up transformer (sold separately), head amplifier (sold separately), or phono equalizer (sold separately) is recommended. For connection instructions, refer to the user manual of the equipment you are connecting.

Care

  • Use the brush provided to remove dirt and dust on the stylus tip.
    Do not use anything except the brush provided. If you use a commercially available brush with long bristles, you may scratch the coil or leader line, causing damage.

  • Always move the brush in the direction in which the record rotates.

  • A stylus cleaner (sold separately) is recommended to remove stubborn dirt.

  • When the product is removed from the tonearm, do not forget to attach the protector and store the product away from the amplifier and other heat sources and magnetic materials.

audio-technica-AT-OC9XEB-Dual-Moving-Coil-Cartridge-4

Specifications

  • Type: MC
  • Frequency response: 20 to 30,000 Hz
  • Output voltage: 0.32 mV (1 kHz, 5 cm/sec.)
  • Channel separation: 25 dB (1 kHz)
  • Output balance: 1.5 dB (1 kHz)
  • Tracking force: 1.8 to 2.2 g (2.0 g standard)
  • Coil impedance: 12 ohms (1 kHz)
  • DC resistance: 12 ohms
  • Recommended load impedance 2 100 ohms (when head amplifier connected)
  • Coil inductance 25 μH (1 kHz)
  • Static compliance. 20 x 10 6 cm/dyne
  • Dynamic compliance: 9 x 10 cm/dyne (100 Hz)
  • Stylus: Elliptical bonded
  • Stylus curvature radius: 0.3×0.7 mil
  • Cantilever· Aluminum pipe
  • Vertical tracking angle 20°
  • Dimensions 17 5 mm (0 69″) x 16 8 mm (0 66″) x 25 7 mm (1 00″) (HxWxD)
  • Mouting: M2.6 x2 Threaded hole
  • Weight· 7 6 g (0 27 oz)
  • Accessories Non-magnetic screwdriver, Brush, Washer x 2, Cartridge installation screws (M2 6) (5 O mm (0 20″) x 2, 8 O mm (0 31″) x 2. 10.0 mm (0.39″) x 2. 12.0 mm (0.47″) x 2). Protector

For product improvement, the prcduct is subject to modification without notice.

Dimensions

audio-technica-AT-OC9XEB-Dual-Moving-Coil-Cartridge-5

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Audio-Technica User Manuals

Related Manuals